scholarly journals Energy savings with the effect of magnetic field using R290/600a mixture as substitute for CFC12 and HFC134a

2008 ◽  
Vol 12 (3) ◽  
pp. 111-120 ◽  
Author(s):  
Kolandavel Mani ◽  
Velappan Selladurai

This paper presents an experimental study on the replacement of CFC12 and HFC134a by the new R290/R600a refrigerant mixture as drop-in replacement refrigerant with and without the effect of magnetic field. Without any modification to the system components drop-in experimental tests were performed on a vapour compression refrigeration system with a reciprocating compressor, which was originally designed to operate with CFC12.The test results with no magnets showed that the refrigerant R290/R600a had 19.9-50.1% higher refrigerating capacity than R12 and 28.6-87.2% than R134a. The mixture R290/R600a consumed 6.8- -17.4% more energy than R12. The coefficient of performance of R290/R600a mixture increases from 3.9-25.1% than R12 at lower evaporating temperatures and 11.8-17.6% at higher evaporating temperatures. The effect of magnetic field force reduced the compressor energy consumption by 1.5-2.5% than with no magnets. The coefficient of performance of the system was higher in the range 1.5-2.4% with the effect of magnetic field force. The R290/600a (68/32 by wt.%) mixture can be considered as an excellent alternative refrigerant for CFC12 and HFC134a systems.

Author(s):  
B Sairamakrishna ◽  
◽  
T Gopala Rao ◽  
N Rama Krishna ◽  
◽  
...  

This experimental investigation exemplifies the design and testing of diffuser at compressor inlet and nozzle at condenser outlet in vapour compression refrigeration system with the help of R134a refrigerant. The diffuser with divergence angle of 12°,14° and the nozzle with convergent angle 12°,14° are designed for same inlet and outlet diameters. Initially diffusers are tested at compressor inlet diffuser is used with inlet diameter equal to exit tube diameter of evaporator and outlet tube diameter is equal to suction tube diameter of the compressor. Diffuser helps to increases the pressure of the refrigerant before entering the compressor it will be helps to reduces the compression work and achieve higher performance of the vapour compression refrigeration system. Then nozzles are testing at condenser outlet, whereas nozzle inlet diameter equal to discharging tube diameter of condenser and outlet diameter equal to inlet diameter of expansion valve. Additional pressure drop in the nozzle helped to achieve higher performance of the vapour compression refrigeration system. The system is analyzes using the first and second laws of thermodynamics, to determine the refrigerating effect, the compressor work input, coefficient of performance (COP).


Nano Hybrids ◽  
2015 ◽  
Vol 9 ◽  
pp. 33-43 ◽  
Author(s):  
A. Manoj Babu ◽  
S. Nallusamy ◽  
K. Rajan

This paper investigates the reliability and performance of a refrigeration system using nanolubricant with 1, 1, 1, 2-Tetrafluoroethane (HFC-134a) refrigerant. Mineral Oil (MO) is mixed with nanoparticles such as Titanium Dioxide (TiO2) and Aluminium Oxide (Al2O3). These mixtures were used as the lubricant instead of Polyolester (POE) oil in the HFC-134a refrigeration system as HFC-134a does not compatible with raw mineral oil. An investigation was done on compatibility of mineral oil and nanoparticles mixture at 0.1 and 0.2 grams / litre with HFC-134a refrigerant. To carry out this investigation, an experimental setup was designed and fabricated in the lab. The refrigeration system performance with the nanolubricant was investigated by using energy consumption test. The results indicate that HFC-134a and mineral oil with above mentioned nanoparticles works normally and safely in the refrigeration system. The refrigeration system performance was better than the HFC-134a and POE oil system. Thus nanolubricant (Mixture of Mineral Oil (MO) and nanoParticles) can be used in refrigeration system to considerably reduce energy consumption and better Coefficient of Performance (COP).


1995 ◽  
Vol 439 ◽  
pp. 474 ◽  
Author(s):  
Thomas R. Metcalf ◽  
Litao Jiao ◽  
Alexander N. McClymont ◽  
Richard C. Canfield ◽  
Han Uitenbroek

2014 ◽  
Vol 984-985 ◽  
pp. 1174-1179
Author(s):  
N. Austin ◽  
P.M. Diaz ◽  
D.S. Manoj Abraham ◽  
N. Kanthavelkumaran

Study on environment friendly mixed refrigerant to replace R134a in vapour compression refrigeration (VCR) System. The mixed refrigerants investigated are propane (R290), butane (R600), isobutene (R600a) and R134a. Even though the ozone depletion potentials of R134a relative to CFC-11 are very low; the global warming potentials are extremely high and also expensive. For this reason, the production and use of R134a will be terminated in the near future. Hydrocarbons are free from ozone depletion potential and have negligible global warming potential. The results showed that, mixed refrigerant with charge of 80 g satisfy the required freezer air temperature when R134a with a charge of 110 g is used as refrigerant. The actual COP of refrigerator using mixed refrigerant was almost nearer that of the system using R134a as refrigerant. The coefficient of performance of the vapour compression refrigeration system using mixed refrigerant MR-3 [R134a/R290/ R600a/ R600 (20/35/40/5)] is having very close value with R134a and the Global warming potential of MR-3 is negligible when compared with R134a. Hence the mixed refrigerant MR-3 is chosen as an environmental friendly alternate refrigerant to R134a. The exergy analysis of the vapour compression refrigeration system using R134a and all the above mixtures are investigated. The effect of evaporator temperature on exergy efficiency and exergy destruction ratio of the system are experimentally studied. The exergy defect in the compressor, condenser, expansion device and evaporator are also obtained. Key words: R134a, Mixed refrigerant, Chlorofluorocarbons, Propane, Butane, Isobutene, REFPROP, COP, ODP, GWP, Exergy, VCR System.


2020 ◽  
Vol 39 (3) ◽  
pp. 776-784
Author(s):  
T.S. Mogaji ◽  
A. Awolala ◽  
O.Z. Ayodeji ◽  
P.B. Mogaji ◽  
D.E. Philip

This study focused on development of an improved vapour compression refrigeration system (IVCR system). Dedicated mechanical subcooling cycle is employed in attaining the developed IVCR system. The system is composed of two cycles cascade refrigeration system working with R134a. It consists of a rectangular shape with total storage space of 0.582 m3, made of galvanized mild steel and internally insulated with 0.05 m polystyrene foam. Tests under a wide range operating temperature conditions were carried out on the developed IVCR system. Performance evaluation of the system was characterized in terms of cooling capacity and coefficient of performance (COP). Experimental results showed that the COP of the subcooled system improved better than that of the main system from 18.0% to about 33.5% over an evaporating temperature range of -10 to 30oC. It can be concluded that the use of dedicated sub cooling cycle in VCR system is more efficient and suitable for the betterment of thermal system performance. Keywords: Vapour compression Refrigeration system, Coefficient of performance, dedicated subcooled system, Condensation temperature, Evaporation temperature.


Author(s):  
P. Kesavulu ◽  
K. Prahlada Rao

The present work is to analyse the performance of VCRS system with two condensers i.e., Serpentine and Spiral tube using Isobutane (R600a) refrigerant. These two condensers are kept in parallel with other components of refrigerating unit while construction. The performance of refrigeration system is checked for each condenser at various cooling loads. The performance of the condenser is measured for whole refrigeration unit in terms of C.O.P, compressor work, Efficiency of the system, Heat Rejection Ratio, and Heat Rejected from Condenser. The result will show that for both condensers for refrigerant R600a, coefficient of performance increases with increase in heating load, increase in refrigerating effect and decrease in compressor work. From the analysis of two condensers, coefficient of performance of refrigeration system using serpentine and spiral condenser VCRS is more compared to conventional VCRS. Also, R600a gives better cooling effect than tetrafluroethane (R134a). The substitution of R134a by R600a is useful in order to generate a good thermo-economic output, zero ODP (Ozone Depletion Potential) and very low GWP (Global Warming Potential).


2014 ◽  
Vol 18 (suppl.2) ◽  
pp. 363-374 ◽  
Author(s):  
Kolandavel Mani ◽  
Vellappan Selladurai ◽  
Natarajan Murugan

In this paper mathematical models were developed using design of experiments technique for the performance prediction of refrigeration system parameters such as refrigerating capacity, power consumption and coefficient of performance. The models developed were checked for their adequacy using F-test. The performances of vapour compression refrigeration system with different refrigerants R12, R134a and R290/R600a were compared. The R290/R600a mixture showed 10.7-23.6% higher coefficient of performance than that with R12 and R134a and it was found that the hydrocarbon mixture with 68% propane and 32% iso-butane could be used as a substitute for R12 and R134a.