scholarly journals Relative measurement error analysis in the process of the Nakagami-m fading parameter estimation

2011 ◽  
Vol 8 (3) ◽  
pp. 341-349
Author(s):  
Vladeta Milentijevic ◽  
Dragan Denic ◽  
Mihajlo Stefanovic ◽  
Stefan Panic ◽  
Dragan Radenkovic

An approach to the relative measurement error analysis in the process of the Nakagami-m fading signal moments estimation will be presented in this paper. Relative error expressions will be also derived for the cases when MRC (Maximal Ratio Combining) diversity technique is performed at the receiver. Capitalizing on them, results will be graphically presented and discussed to show the influence of various parameters, such as diversity order and fading severity on the relative measurement error bounds.

2017 ◽  
Vol 9 (6) ◽  
pp. 58 ◽  
Author(s):  
Espen Gaarder Haug

In this paper we show how it is possible to measure the Planck length through a series of different methods. One of these measurements is totally independent of big G, but moving from the theoretical realm to the empirical realm would require particle accelerators far more powerful than the ones that we have today. However, a Cavendish-style experiment can also be performed to find the Planck length with no knowledge of the value of big G. Furthermore, the Cavendish style set-up gives half of the relative measurement error in the Planck length compared to the measurement error in big G.


2019 ◽  
Vol 10 (1) ◽  
pp. 90-98 ◽  
Author(s):  
S. G. Sandomirski

Magnetic testing of steels' mechanical properties is based on their correlation with steels' magnetic parameters. The purpose of this work was to establish dependence of the attainable correlation coefficient Rmax between measurement results and the parameter values a on the reduced error of its measurement. The article proposes a model of the correlation field between the parameter true values and the results of its measurement with a given reduced error δ. The merits and legitimacy of using the model for estimation of the achievable correlation coefficient Rmax are substantiated. Analysis of influence of δ parameter measurement in different ranges d of its change on Rmax is carried out. Results are compared with the previous analysis for the relative measurement error. It has been established in this work that the coefficient Rmax calculated for the reduced measurement error is always smaller than Rmax one calculated for the relative measurement error. However in the practically important range of variation of d with δ ≤ 0.05 the difference between the Rmax values calculated for the reduced and relative measurement errors is not large. This allows us to use the developed formula for the dependence Rmax = Rmax (δ, d) at Rmax ≥ 0.8 for both relative and reduced measurement errors δ. The obtained result allows us using the reduced measurement error of a metrologically certified measuring instrument to obtain the maximum attainable correlation coefficient between the true values and the results of measuring a parameter in a given range of its change without measurements. As an example, we define the conditions for the non-destructive testing of steels under which one can use measuring of magnetic parameters with the installation certified based on the reduced measurement error.


2021 ◽  
Vol 11 (11) ◽  
pp. 1507
Author(s):  
Katrin Trentzsch ◽  
Benjamin Melzer ◽  
Heidi Stölzer-Hutsch ◽  
Rocco Haase ◽  
Paul Bartscht ◽  
...  

One of the core problems for people with multiple sclerosis (pwMS) is the impairment of their ability to walk, which can be severely restrictive in everyday life. Therefore, monitoring of ambulatory function is of great importance to be able to effectively counteract disease progression. An extensive gait analysis, such as the Dresden protocol for multidimensional walking assessment, covers several facets of walking impairment including a 2-min walk test, in which the distance taken by the patient in two minutes is measured by an odometer. Using this approach, it is questionable how precise the measuring methods are at recording the distance traveled. In this project, we investigate whether the current measurement can be replaced by a digital measurement method based on accelerometers (six Opal sensors from the Mobility Lab system) that are attached to the patient’s body. We developed two algorithms using these data and compared the validity of these approaches using the results from 2-min walk tests from 562 pwMS that were collected with a gold-standard odometer. In 48.4% of pwMS, we detected an average relative measurement error of less than 5%, while results from 25.8% of the pwMS showed a relative measurement error of up to 10%. The algorithm had difficulties correctly calculating the walking distances in another 25.8% of pwMS; these results showed a measurement error of more than 20%. A main reason for this moderate performance was the variety of pathologically altered gait patterns in pwMS that may complicate the step detection. Overall, both algorithms achieved favorable levels of agreement (r = 0.884 and r = 0.980) with the odometer. Finally, we present suggestions for improvement of the measurement system to be implemented in the future.


Author(s):  
Mikhail Nikolaevich Pokusaev ◽  
Tat'iana Vladimirovna Khomenko ◽  
Konstantin Evgenievich Khmelnitsky ◽  
Alexei Alekseevich Kadin

The article discusses the results of experiments on measuring vibration of the hull of a small vessel using various methods of vibroinsulation of outboard motors SEA PRO (nominal capacity 5 h.p.) and SEA PRO (nominal capacity 2.5 h.p.). There have been recorded the harmful effects of prolonged exposure to vibration on the human body, as well as on the boat hull and outboard motor. The peak vibration level was measured and the effectiveness of different types of vibroinsulation was evaluated. The experiments were carried out using a vibrometer Ekofizika-110A made in Russia (relative measurement error ± 0.5 dB) and a vibrometer AR63A made in China (relative measurement error ± 5%). The illustrations of the vibrometers used are presented. It was determined that a multi-layer transom cover is a fairly effective way to reduce the vibration of the motor boat hull. The highest efficiency was achieved for the outboard motor SEA PRO 5.0 when it was running at full speed; a 17.3% reduction in vibration was recorded when using the relative value of vibration acceleration (dB). For the outboard motor SEA PRO 2.5 running at medium speed the decreased vibration (9.5%) was recorded when using the relative value of vibration acceleration (dB). The conclusion has been made about the prospects of reducing the vibration of outboard motors and the need for scientific and experimental research, as well as for the development of standards for permissible vibration of the motor boat hull, which can limit the harmful effect on the crew, the boat structure and the outboard motor. The formula of the logarithmic levels of vibration acceleration in relative units is given in accordance with generally accepted sanitary rules and regulations.


2014 ◽  
Vol 2014 ◽  
pp. 1-8
Author(s):  
Feng-Gong Lang ◽  
Xiao-Ping Xu

We mainly present the error analysis for two new cubic spline based methods; one is a lacunary interpolation method and the other is a very simple quasi interpolation method. The new methods are able to reconstruct a function and its first two derivatives from noisy function data. The explicit error bounds for the methods are given and proved. Numerical tests and comparisons are performed. Numerical results verify the efficiency of our methods.


2011 ◽  
Vol 38 (10) ◽  
pp. 1008009
Author(s):  
Xu Yang ◽  
Tang Feng ◽  
Wang Xiangzhao ◽  
Xu Jinghao ◽  
Fan LiliCheng Xin

2017 ◽  
Vol 46 (12) ◽  
pp. 1217007
Author(s):  
范慧敏 Fan Huimin ◽  
裘桢炜 Qiu Zhenwei ◽  
袁银麟 Yuan Yinlin ◽  
康 晴 Kang Qing ◽  
洪 津 Hong Jin

Sign in / Sign up

Export Citation Format

Share Document