scholarly journals Combining Ionic Computer Models to Follow the Propagation of Electrical Activity of Atrial Fibrillation in the Left Atrium.

Author(s):  
Saaima Ahmad ◽  
Mahmoud Ehnesh ◽  
Peter Stafford ◽  
G. Andre Ng ◽  
Fernando Schlindwein
2021 ◽  
Vol 12 ◽  
Author(s):  
João Salinet ◽  
Rubén Molero ◽  
Fernando S. Schlindwein ◽  
Joël Karel ◽  
Miguel Rodrigo ◽  
...  

Electrocardiographic imaging (ECGI) is a technique to reconstruct non-invasively the electrical activity on the heart surface from body-surface potential recordings and geometric information of the torso and the heart. ECGI has shown scientific and clinical value when used to characterize and treat both atrial and ventricular arrhythmias. Regarding atrial fibrillation (AF), the characterization of the electrical propagation and the underlying substrate favoring AF is inherently more challenging than for ventricular arrhythmias, due to the progressive and heterogeneous nature of the disease and its manifestation, the small volume and wall thickness of the atria, and the relatively large role of microstructural abnormalities in AF. At the same time, ECGI has the advantage over other mapping technologies of allowing a global characterization of atrial electrical activity at every atrial beat and non-invasively. However, since ECGI is time-consuming and costly and the use of electrical mapping to guide AF ablation is still not fully established, the clinical value of ECGI for AF is still under assessment. Nonetheless, AF is known to be the manifestation of a complex interaction between electrical and structural abnormalities and therefore, true electro-anatomical-structural imaging may elucidate important key factors of AF development, progression, and treatment. Therefore, it is paramount to identify which clinical questions could be successfully addressed by ECGI when it comes to AF characterization and treatment, and which questions may be beyond its technical limitations. In this manuscript we review the questions that researchers have tried to address on the use of ECGI for AF characterization and treatment guidance (for example, localization of AF triggers and sustaining mechanisms), and we discuss the technological requirements and validation. We address experimental and clinical results, limitations, and future challenges for fruitful application of ECGI for AF understanding and management. We pay attention to existing techniques and clinical application, to computer models and (animal or human) experiments, to challenges of methodological and clinical validation. The overall objective of the study is to provide a consensus on valuable directions that ECGI research may take to provide future improvements in AF characterization and treatment guidance.


2019 ◽  
Vol 25 (4) ◽  
pp. 146
Author(s):  
S. A. Vachev ◽  
A. V. Bogachev-Prokof'ev ◽  
A. S. Zotov ◽  
D. A. Elesin ◽  
S. V. Voronin ◽  
...  

2021 ◽  
Vol 5 (2) ◽  
Author(s):  
Masatoshi Narikawa ◽  
Masayoshi Kiyokuni ◽  
Junya Hosoda ◽  
Toshiyuki Ishikawa

Abstract Background Transseptal puncture and pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF) are generally performed via the inferior vena cava (IVC). However, in cases where the IVC is inaccessible, a specific strategy may be needed. Case summary An 86-year-old woman with paroxysmal AF and an IVC filter in situ was referred to our hospital for ablation therapy. An IVC filter for pulmonary embolism and deep venous thrombosis had been implanted 15 years prior, therefore we selected a transoesophageal echocardiography (TOE)-guided transseptal puncture using a superior vena cava (SVC) approach. After the single transseptal puncture, we performed fast anatomical mapping, voltage mapping by multipolar mapping catheter, and then PVI by contact force-guided radiofrequency catheter using a steerable sheath. Following the ablation, bidirectional conduction block between the four pulmonary veins and the left atrium was confirmed by both radiofrequency and mapping catheter. No complications occurred and no recurrence of AF was documented in the 12 months after the procedure. Discussion When performing a transseptal puncture during AF ablation, an SVC approach, via access through the right internal jugular vein, enables the sheath to directly approach the left atrium without angulation and improves operability of the ablation catheter. Combining the use of general anaesthesia, TOE, a steerable sheath, and contact force-guided ablation may contribute to achieving minimally invasive PVI with a single transseptal puncture via an SVC approach.


Author(s):  
Adil K. Baimbetov ◽  
Kenzhebek A. Bizhanov ◽  
Kuat B. Abzaliyev ◽  
Binali A. Bairamov ◽  
Ilinara A. Yakupova

2021 ◽  
Author(s):  
Mariano Rillo ◽  
Zefferino Palamà ◽  
Raffaele Punzi ◽  
Salvatore Vitanza ◽  
Angelo Aloisio ◽  
...  

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Yan-Jing Wang ◽  
Huan Sun ◽  
Xiao-Fei Fan ◽  
Meng-Chao Zhang ◽  
Ping Yang ◽  
...  

Abstract Background The ablation targets of atrial fibrillation (AF) are adjacent to bronchi and pulmonary arteries (PAs). We used computed tomography (CT) to evaluate the anatomical correlation between left atrium (LA)-pulmonary vein (PV) and adjacent structures. Methods Data were collected from 126 consecutive patients using coronary artery CT angiography. The LA roof was divided into three layers and nine points. The minimal spatial distances from the nine points and four PV orifices to the adjacent bronchi and PAs were measured. The distances from the PV orifices to the nearest contact points of the PVs, bronchi, and PAs were measured. Results The anterior points of the LA roof were farther to the bronchi than the middle or posterior points. The distances from the nine points to the PAs were shorter than those to the bronchi (5.19 ± 3.33 mm vs 8.62 ± 3.07 mm; P < .001). The bilateral superior PV orifices, especially the right superior PV orifices were closer to the PAs than the inferior PV orifices (left superior PV: 7.59 ± 4.14 mm; right superior PV: 4.43 ± 2.51 mm; left inferior PV: 24.74 ± 5.26 mm; right inferior PV: 22.33 ± 4.75 mm) (P < .001). Conclusions The right superior PV orifices were closer to the bronchi and PAs than other PV orifices. The ablation at the mid-posterior LA roof had a higher possibility to damage bronchi. CT is a feasible method to assess the anatomical adjacency in vivo, which might provide guidance for AF ablation.


Sign in / Sign up

Export Citation Format

Share Document