scholarly journals Electron and Photon Performance and Electron pT Spectrum Measurement with ATLAS in pp Collisions at \sqrt s = 7 TeV

2011 ◽  
Author(s):  
Scott Snyder
Author(s):  
M. L. Knotek

Modern surface analysis is based largely upon the use of ionizing radiation to probe the electronic and atomic structure of the surfaces physical and chemical makeup. In many of these studies the ionizing radiation used as the primary probe is found to induce changes in the structure and makeup of the surface, especially when electrons are employed. A number of techniques employ the phenomenon of radiation induced desorption as a means of probing the nature of the surface bond. These include Electron- and Photon-Stimulated Desorption (ESD and PSD) which measure desorbed ionic and neutral species as they leave the surface after the surface has been excited by some incident ionizing particle. There has recently been a great deal of activity in determining the relationship between the nature of chemical bonding and its susceptibility to radiation damage.


2019 ◽  
Vol 55 (8) ◽  
Author(s):  
A. Gutiérrez-Rodríguez ◽  
M. Köksal ◽  
A. A. Billur ◽  
M. A. Hernández-Ruíz

2020 ◽  
Vol 102 (11) ◽  
Author(s):  
G. Aad ◽  
B. Abbott ◽  
D. C. Abbott ◽  
A. Abed Abud ◽  
K. Abeling ◽  
...  

2021 ◽  
Vol 103 (3) ◽  
Author(s):  
M. Andriamirado ◽  
A. B. Balantekin ◽  
H. R. Band ◽  
C. D. Bass ◽  
D. E. Bergeron ◽  
...  

Electronics ◽  
2020 ◽  
Vol 10 (1) ◽  
pp. 65
Author(s):  
Quan Zhao ◽  
Ling Tong ◽  
Bo Gao

The classical two-channel push-pull chirp transform spectrometer (CTS) has been widely applied in satellite-borne remote sensing systems for earth observation and deep space exploration. In this paper, we present two simplified structures with single M(l)-C(s) CTS arrangements for the spectral analysis of stationary signals. A simplified CTS system with a single M(l)-C(s) arrangement and a time delay line was firstly developed. Another simplified structure of CTS with a M(l)-C(s) arrangement and a frequency conversion channel was also developed for spectral analysis of stationary signals. Simulation and experiment results demonstrate that the two simplified arrangements can both realize spectrum measurement for the stationary signals and obtain the same frequency resolution, amplitude accuracy and system sensitivity as that of the classical two-channel push–pull CTS system. Compared to the classical CTS structure, the two simplified arrangements require fewer devices, save power consumption and have reduced mass. The matching problem between the two channels can be avoided in the two simplified arrangements. The simplified CTS arrangements may have potential application in the spectrum measurement of stationary signals in the field of aviation and spaceflight.


Sign in / Sign up

Export Citation Format

Share Document