scholarly journals SUMMARY OF RESEARCH WORK ON THE EVALUATION ON LONG TERM STABILITY OF ARTIFICIAL SLOPE PROTECTION

2015 ◽  
Vol 1 (2) ◽  
Author(s):  
Ros Soty ◽  
Dwikorita Karnawati ◽  
Kenji Aoki

Application of GPR, RedExplorer1.4 and GeoStudio2004 have been used to evaluate the overall stability condition of a steep slope along Kalibawang irrigation channel km 8.5, Kulon Progo Regency, Yogyakarta Special Province, Indonesia, that this slope slid down in 1990 and was restabilized by cut to be gentler and covered by shotcrete. Topographic map and engineering geological map in scale 1:2000 have been established prior to the detail investigation. Three drilling logs with in-situ test, SPT and CPT, and samplings have been made and sent to soil mechanic laboratory for index properties tests, and a slope profile along the main axe will be also created for stability analysis through GeoStudio2004. Moreover, GPR has been used to run on a full slope surface to detect the distribution of fractures and/or cavities behind the shotcrete and the results have been interpreted by the aid of RedExplorer1.4.Three profiles showing the rate and depth of fractures and/or cavities are established whereas the slope stability analysis through GeoStudio2004 is the next target of the research. The author is expecting the result from the integration of GPR interpretation and GeoStudio2004 to figure out the overall stability with respect to its existing conditions and its own geometry. Keywords: GPR, GeoStudio2004, overall stability, fracture and/or cavities.

2021 ◽  
Vol 13 (1) ◽  
Author(s):  
La Li ◽  
Weijia Liu ◽  
Kai Jiang ◽  
Di Chen ◽  
Fengyu Qu ◽  
...  

AbstractZn-ion hybrid supercapacitors (SCs) are considered as promising energy storage owing to their high energy density compared to traditional SCs. How to realize the miniaturization, patterning, and flexibility of the Zn-ion SCs without affecting the electrochemical performances has special meanings for expanding their applications in wearable integrated electronics. Ti3C2Tx cathode with outstanding conductivity, unique lamellar structure and good mechanical flexibility has been demonstrated tremendous potential in the design of Zn-ion SCs, but achieving long cycling stability and high rate stability is still big challenges. Here, we proposed a facile laser writing approach to fabricate patterned Ti3C2Tx-based Zn-ion micro-supercapacitors (MSCs), followed by the in-situ anneal treatment of the assembled MSCs to improve the long-term stability, which exhibits 80% of the capacitance retention even after 50,000 charge/discharge cycles and superior rate stability. The influence of the cathode thickness on the electrochemical performance of the MSCs is also studied. When the thickness reaches 0.851 µm the maximum areal capacitance of 72.02 mF cm−2 at scan rate of 10 mV s−1, which is 1.77 times higher than that with a thickness of 0.329 µm (35.6 mF cm−2). Moreover, the fabricated Ti3C2Tx based Zn-ion MSCs have excellent flexibility, a digital timer can be driven by the single device even under bending state, a flexible LED displayer of “TiC” logo also can be easily lighted by the MSC arrays under twisting, crimping, and winding conditions, demonstrating the scalable fabrication and application of the fabricated MSCs in portable electronics.


2021 ◽  
Vol 336 ◽  
pp. 457-468
Author(s):  
Charlotte Molinier ◽  
Marina Picot-Groz ◽  
Océane Malval ◽  
Sophie Le Lamer-Déchamps ◽  
Joël Richard ◽  
...  

2021 ◽  
Vol 1193 (1) ◽  
pp. 012077
Author(s):  
A Mínguez ◽  
J Moreno ◽  
J De Vicente

Abstract Gauge blocks are one of the most widespread measurement standards (etalons) in dimensional metrology laboratories. Among all its properties, it is worth highlighting the importance of dimensional stability. This property allows to classify these measuring instruments in quality grades. Although the gauge blocks should be dimensionally stable, it can be observed that there is a drift that can be observed when the calibration history is revised. In this document, authors present a statistical method for the estimation of the dimensional stability of gauge blocks using the calibration history of samples from the main manufacturers. In addition, all the samples have been subjected to metallographic analysis to evaluate the structure.


2013 ◽  
Vol 23 (11) ◽  
pp. 2129-2154 ◽  
Author(s):  
HÉLÈNE BARUCQ ◽  
JULIEN DIAZ ◽  
VÉRONIQUE DUPRAT

This work deals with the stability analysis of a one-parameter family of Absorbing Boundary Conditions (ABC) that have been derived for the acoustic wave equation. We tackle the problem of long-term stability of the wave field both at the continuous and the numerical levels. We first define a function of energy and show that it is decreasing in time. Its discrete form is also decreasing under a Courant–Friedrichs–Lewy (CFL) condition that does not depend on the ABC. Moreover, the decay rate of the continuous energy can be determined: it is exponential if the computational domain is star-shaped and this property can be illustrated numerically.


2019 ◽  
Vol 2019 ◽  
pp. 1-6 ◽  
Author(s):  
Nils Kristian Prenzler ◽  
Eugen Kludt ◽  
Thomas Giere ◽  
Rolf Salcher ◽  
Thomas Lenarz ◽  
...  

Objectives/Hypothesis. Comparing long term stability of the Middle Ear Transducers (MET) of the 1st generation T1 (Otologics LLC) with the current generation T2 (Cochlear Ltd.) in all our clinical cases with standard incus coupling. Study Design. Retrospective chart review. Methods. 52 ears implanted with a MET device between 2008 and 2016 were analyzed retrospectively. All patients suffered from sensorineural hearing loss and the actuator was coupled to the body of the incus (standard coupling). 23 ears were implanted with the transducer T1 (Otologics LLC) between 2008 and 2011 and 29 ears were implanted with the current transducer T2 since 2011 (Otologics LLC/Cochlear Ltd.). Latest available in situ and bone conduction (BC) thresholds were exploited for a follow-up period of up to 7 years after first fitting. Long term stability of coupling and actuator performance was evaluated by tracking differences between in situ and BC thresholds. Results. In the T1 group, 9 out of 23 implants were still used by the patients at their last follow-up visit (average observation time 3.7 yrs.; min 1.0 yrs., max 7.4 yrs.). In 9 patients a technical failure identified by a decrease of in situ threshold of more than 15 dB compared to BC thresholds [Δ (in situ – BC)] lead to non-usage of the implant and 7 explantations. Five other explantations occurred due to medical reasons such as BC threshold decrease, infection, or insufficient speech intelligibility with the device. In the T2 group, 23 out of 29 implants were still used at the most current follow-up visit (average observation time 3.3 yrs.; min 1.0 yrs., max 4.8 yrs.). No technical failures were observed up to more than 4 years after implantation. Five T2 patients discontinued using the device due to insufficient benefit; two of these patients were explanted. One patient had to be explanted before the activation of the device due to disorders of wound healing. Nevertheless, a small but significant decrease of hearing loss corrected coupling efficiency [Δ (in situ – BC)] was seen in the T2 group. Conclusions. In contrast to the T1 transducers of the earlier generation of MET systems where technical failures occurred frequently, no technical failures were detected after 29 implantations with the current T2 transducers. However, a small but significant decline of transmission efficiency was observable even in the T2 implanted group.


2020 ◽  
Vol 745 ◽  
pp. 140989
Author(s):  
Jinhee Park ◽  
Jinsung An ◽  
Hyeonyong Chung ◽  
Sang Hyun Kim ◽  
Kyoungphile Nam

Sign in / Sign up

Export Citation Format

Share Document