scholarly journals APPLICATION OF NEUTRON ACTIVATION ANALYSIS IN CHARACTERIZATION OF ENVIRONMENTAL SRM SAMPLES

2010 ◽  
Vol 9 (2) ◽  
pp. 231-235 ◽  
Author(s):  
Diah Dwiana Lestiani ◽  
Muhayatun Muhayatun ◽  
Natalia Adventini

Neutron activation analysis (NAA) is a nuclear technique that is excellent, multi-elemental, sensitive and has limit detection up to nanogram level. The application of NAA in analysis of Standard Reference Material (SRM) National Institute of Standard Technology (NIST) 1633b Coal Fly Ash and SRM NIST 1646a Estuarine Sediment was carried out for NAA laboratory inter-comparison program. The samples were distributed by Technology Centre for Nuclear Industry Material, National Nuclear Energy Agency as a coordinator of the inter-comparison program. The samples were irradiated in rabbit facility of G.A. Siwabessy reactor with neutron flux ~ 1013 n.cm-2.s-1, and counted with HPGe spectrometry gamma detector. Several trace elements in these samples were detected. The concentration of Al, Mg, K, Na and Ti in SRM NIST 1633b were 15.11, 7.35, 2.09, 0.192 and 0.756% respectively and the concentration of As, Cr, Mn, Se, V, Sb, Co, Cs, La, Sc and Sm were 137.0, 195.6, 129.4, 9.61, 305.8, 5.45, 56.2, 11.18, 83.73, 41.1 and 19.13 mg/kg respectively. The analysis result in SRM NIST 1646a of the concentration of Al and Na were 2.15 and 0.70% and the concentration of As, Cr, Co, La and Sc were 5.75, 36.3, 4.58, 15.67 and 4.00 mg/kg respectively. These results analysis had relative bias and u-test ranged from 0.4-11.3% and 0.15-2.25. The accuracy and precision evaluation based on International Atomic Energy Agency (IAEA) criteria was also applied. The result showed that NAA technique is applicable for the environmental samples analysis, and it also showed that the NAA laboratory in BATAN Bandung has a good performance.   Keywords: NAA, inter-comparison, estuarine sediment, coal fly ash, environmental samples

2012 ◽  
Vol 15 (1) ◽  
Author(s):  
Diah Dwiana Lestiani ◽  
Syukria Kurniawati ◽  
Natalia Adventini

Inter-comparison program is a good tool for improving quality and to enhance the accuracy and precision of theanalytical techniques. By participating in this program, laboratories could demonstrate their capability andensuring the quality of analysis results generated by analytical laboratories. The Neutron Activation Analysis(NAA) laboratory at National Nuclear Energy Agency of Indonesia (BATAN), Nuclear Technology Center forMaterials and Radiometry-PTNBR laboratory participated in inter-comparison tests organized by NAA workinggroup. Inter-comparison BATAN 2009 was the third inter-laboratory analysis test within that project. Theparticipating laboratories were asked to analyze for trace elements using neutron activation analysis as theprimary technique. Three materials were distributed to the participants representing foodstuff, and environmentalmaterial samples. Samples were irradiated in rabbit facility of G.A. Siwabessy reactor with neutron flux ~ 1013n.cm-2.s-1, and counted with HPGe detector of gamma spectrometry. Several trace elements in these sampleswere detected. The accuracy and precision evaluation based on International Atomic Energy Agency (IAEA)criteria was applied. In this paper the PTNBR NAA laboratory results is evaluated.Keywords: inter-comparison, neutron activation analysis, trace elements, foodstuff, environmental samples,NAA laboratory


Sign in / Sign up

Export Citation Format

Share Document