scholarly journals Gender disparity of changes in heart rate during the six-minute walk test among patients with chronic obstructive airway disease

2017 ◽  
Vol 10 (7) ◽  
Author(s):  
Esmaeil Alibakhshi ◽  
Luis Lores Obradors ◽  
Raffaele Fiorillo ◽  
Mostafa Ghaneii ◽  
Ali Qazvini
Author(s):  
Ruchita B. Hajare ◽  
Raziya Nagarwala ◽  
Ashok Shyam ◽  
Parag Sancheti

Background: Six minute walk test (6MWT) is a sub-maximal exercise test, used as a clinical indicator of the functional capacity, in patients with cardiopulmonary diseases. It is simple, objective and reproducible test. The present study was designed to assess correlation of six minute walk test with spirometry parameters, in patients with chronic obstructive pulmonary disease.Methods: In this cross sectional study, fifty patients diagnosed with chronic obstructive pulmonary disease (GOLD criteria) coming to tertiary center were recruited according to inclusion and exclusion criteria. All patients underwent spirometric measurement. Spirometric indices including FEV1, FVC, FEV1/FVC and MVV were tested using computerized spirometer. 6MWT was performed following American Thoracic Society (ATS) guidelines. Percent (%) predicted 6MWD was calculated. Correlation between spirometry and 6MWT was assessed.Results: It was found that correlation between 6MWT and spirometry is statistically significant. There is significant strong positive correlation between percent predicted 6MWD and FEV1 (r=0.850 and p= <0.001), whereas there is significant moderate correlation between percent predicted 6MWD and FVC (r=0.554 and p= <0.001), FEV1/FVC (r=0.509 and p= <0.001) and MVV (r=0.615 and p= <0.001).Conclusions: In chronic obstructive pulmonary disease, percent predicted 6mwd significantly correlated with the spirometry parameters (FEV1, FVC, FEV1/FVC, and MVV). 6MWD decreases as there is decline in the pulmonary function. 6MWT can be a useful replacement of spirometry in assessment of severity of COPD.


Author(s):  
Yara Dinakar ◽  
Pradeep Panchadi Kiran ◽  
Akshaya K. Mohanty ◽  
Praveen Kishore Sahu ◽  
Anita Mohanty

Background: Six‑Minute Walk Test (6MWT) is a simple, objective, reproducible test which correlated well with different spirometric indices, and thus able to predict severity of Chronic Obstructive Pulmonary Disease (COPD) and can replace spirometry in resource poor set‑up. Here, author evaluated the correlation of 6 minute walk distance (6MWD) with spirometric indices in COPD patients and the potential of 6MWT as an alternative to the assessment of severity of COPD.Methods: This cross-sectional observational study included a total of 80 COPD patients, diagnosed by GOLD criteria (Post bronchodilator FEV1/ FVC ratio <0.7). Modified Medical Research Council (mMRC) grading was used (age, weight, height, body mass index- BMI and breathlessness) and all the patients underwent spirometric measurement of FEV1, FVC and FEV1/ FVC ratio and tests were repeated after bronchodilation using 200-400 μg of salbutamol. 6MWT was performed following American Thoracic Society (ATS) protocol of 6MWT and distance was measured in meters.Results: Author found significant negative correlation of 6MWT with age (r=-0.384, p=0.00) and mMRC grading of dyspnea (r=-0.559, p=0.00) and significant positive correlation with height (r=0.267, p=0.019) and weight (r=0.293, p=0.008). Significant positive correlation of 6MWD was noted with post bronchodilator FEV1(r=0.608, p=0.00), FEV1% (r=0.429, p=0.00), FVC (r=0.514 p=0.00), FVC% (r=0.313 p=0.005), FEV1/FVC % (r=0.336, p=0.001). Positive correlation was also observed between 6MWT and BMI but statistically insignificant (r=0.177, p=0.116). There was significant negative correlation between 6MWT and GOLD staging (r=-0.536, p=0.00).Conclusions: This finding concludes that 6MWT can be used for the assessment of severity of disease in COPD patients in places where spirometry is not available.


2021 ◽  
Vol 28 (3) ◽  
pp. 267-275
Author(s):  
Mariana Kalazich-Rosales ◽  
Camila Mautner-Molina ◽  
Cecilia König-Araya ◽  
Francisca Fuentes-Leal ◽  
Carlos Cárcamo-Ibaceta ◽  
...  

ABSTRACT The six-minute walk test (6MWT) is widely used to measure functional capacity in special populations. However, the factors associated with its performance in candidates for bariatric surgery are unclear. Therefore, this study aimed to investigate the influence of anthropometric and physiological factors in the 6MWT performance in bariatric surgery candidates. This cross-sectional study included 107 candidates for bariatric surgery. Anthropometric factors considered: gender, weight, height, body mass index (BMI), waist-to-hip, and waist-to-height ratios. Along with distance covered during 6MWT, physiological factors such as ratings of perceived exertion (RPE) and heart rate reserve percentage used (%HRR) were recorded. Among the 107 patients (mean age: 39.6 years), 83 volunteers were accepted to perform the 6MWT. No gender differences were observed in terms of distance covered, %HRR, and RPE during the 6MWT. Moreover, BMI and %HRR explained 21% of the 6MWT distance covered. Furthermore, participants with BMI ≤41.5 kg/m2 walked ~50 meters more than their peers above this level (p=0.05). Interestingly, heart rate increase during the 6MWT was lower than described for healthy populations. BMI and %HRR partially explain the variability of the 6MWT performance in bariatric surgery candidates.


CHEST Journal ◽  
2011 ◽  
Vol 140 (4) ◽  
pp. 585A
Author(s):  
Mohammad Shameem ◽  
Asrar Ahmad ◽  
Qayyum Hussain ◽  
Rakesh Bhargava ◽  
Zuber Ahmad ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document