PLC Program for Pumping Instrumentation and Control Skid B (S-109)

2001 ◽  
Author(s):  
M R KOCH
Keyword(s):  
2014 ◽  
Vol 721 ◽  
pp. 265-268
Author(s):  
Mao Qi Huang ◽  
Jian Hong Ke ◽  
Xiao Long Wu

Greenhouse environment system is an often nonlinear, change and inertia complex system. It is very hard to build math model and control. Since moisture and temperature have a influence to crops grow, we select them to build the manner of control system, applying fuzzy control system to design moisture and temperature controller, and to write fuzzy control program based PLC, then we should observe the factual control effect. The result of system running show: when temperature is set to 25oC and moisture is 80%RH, the process of control is stable and the system is very stable, it can meet the greenhouse requirement.


2020 ◽  
Vol 4 (6) ◽  
pp. 1007-1016
Author(s):  
Arief Goeritno ◽  
Sandi Tirta

A PLC based simulator has been assembled for controlling road traffic at ship line crossings. The objectives of this study include (i) assembling a miniature bridge body, a lift-drop back mechanism for highway traffic at ship crossings, and an operating system based on a programmable logic controller (PLC) and (ii) measuring the performance of the operating system through its presence input-output signal. Assembly with the following stages: (i) implementation of miniature bridge construction; (ii) selection and placement of sensors; (iii) installation of pumps for hydraulic systems; (iv) installation of servo motor assisted latches; (v) installation of traffic control lights and indicators; and (vi) manufacture of operation panels, wiring, and installation of PLC systems. Mitsubishi PLC system programming is based on compiling algorithms and ladder diagrams with GX Works-2 32 bit. Performance measurement includes (i) when synchronization between the operating system and control on the PLC in the form of input from the operation panel and sensors on the input line are processed in the PLC program to produce an output in the form of appropriate and precise control, (ii) when the sensors installed in the system operation has functioned as programmed into the PLC, and (iii) during the process of lifting and lowering the miniature of the bridge body, there is a time difference of 26 seconds with the condition that the lifting time is longer than the time of lowering the miniature bridge body. The general conclusion is that the miniature of the bridge body and the operating system that has been built can be used as a simulator for the existence of a bridge that can be lifted and lowered again as a highway traffic lane at a ship crossing.


Author(s):  
Ye Liu ◽  
Tao Gao ◽  
Chong Yuan ◽  
Tianze Li

This design introduced the operation process of the lift. In accordance with the requirements of energy conservation design teaching building Mingde building automatic control of the lift. By setting the TDD slope integration time Siemens MM440 transducer to control the elevator has the speed, and by j1.1 jv tractors to carry and transfer power make the elevator running. The Siemens S7-200 series PLC as control host CPU226, and extends the S7-200 series of I/O extension module (EM223) to control the input and output, complete the elevator traction motor and frequency converter, direction, floor, according to the layer station call, capsules in operation, the safety protection command signal for management and control functions. From inside the elevator running status signals, hall, driving direction, traffic location floor integrated PLC program control internal rule.


Author(s):  
R. R. Dils ◽  
P. S. Follansbee

Electric fields have been applied across oxides growing on a high temperature alloy and control of the oxidation of the material has been demonstrated. At present, three-fold increases in the oxidation rate have been measured in accelerating fields and the oxidation process has been completely stopped in a retarding field.The experiments have been conducted with an iron-base alloy, Pe 25Cr 5A1 0.1Y, although, in principle, any alloy capable of forming an adherent aluminum oxide layer during oxidation can be used. A specimen is polished and oxidized to produce a thin, uniform insulating layer on one surface. Three platinum electrodes are sputtered on the oxide surface and the specimen is reoxidized.


Author(s):  
D. M. DePace

The majority of blood vessels in the superior cervical ganglion possess a continuous endothelium with tight junctions. These same features have been associated with the blood brain barrier of the central nervous system and peripheral nerves. These vessels may perform a barrier function between the capillary circulation and the superior cervical ganglion. The permeability of the blood vessels in the superior cervical ganglion of the rat was tested by intravenous injection of horseradish peroxidase (HRP). Three experimental groups of four animals each were given intravenous HRP (Sigma Type II) in a dosage of.08 to.15 mg/gm body weight in.5 ml of.85% saline. The animals were sacrificed at five, ten or 15 minutes following administration of the tracer. Superior cervical ganglia were quickly removed and fixed by immersion in 2.5% glutaraldehyde in Sorenson's.1M phosphate buffer, pH 7.4. Three control animals received,5ml of saline without HRP. These were sacrificed on the same time schedule. Tissues from experimental and control animals were reacted for peroxidase activity and then processed for routine transmission electron microscopy.


Author(s):  
G. Mazzocchi ◽  
P. Rebuffat ◽  
C. Robba ◽  
P. Vassanelli ◽  
G. G. Nussdorfer

It is well known that the rat adrenal zona glomerulosa steroidogenic activity is controlled by the renin-angiotensin system. The ultrastructural changes in the rat zona glomerulosa cells induced by renovascular hypertension were described previously, but as far as we are aware no correlated biochemical and morphometric investigations were performed.Twenty adult male albino rats were divided into 2 experimental groups. One group was subjected to restriction of blood flow to the left kidney by the application of a silver clip about the left renal artery. The other group was sham-operated and served as a control. Renovascular hypertension developed in about 10 days: sistolic blood pressure averaged 165 ± 6. 4 mmHg, whereas it was about 110 ± 3. 8 mmHg in the control animals. The hypertensive and control rats were sacrificed 20 days after the operation. The blood was collected and plasma renin activity was determined by radioimmunological methods. The aldosterone concentration was radioimmunologically assayed both in the plasma and in the homogenate of the left capsular adrenal gland.


Author(s):  
Henry I. Smith ◽  
D.C. Flanders

Scanning electron beam lithography has been used for a number of years to write submicrometer linewidth patterns in radiation sensitive films (resist films) on substrates. On semi-infinite substrates, electron backscattering severely limits the exposure latitude and control of cross-sectional profile for patterns having fundamental spatial frequencies below about 4000 Å(l),Recently, STEM'S have been used to write patterns with linewidths below 100 Å. To avoid the detrimental effects of electron backscattering however, the substrates had to be carbon foils about 100 Å thick (2,3). X-ray lithography using the very soft radiation in the range 10 - 50 Å avoids the problem of backscattering and thus permits one to replicate on semi-infinite substrates patterns with linewidths of the order of 1000 Å and less, and in addition provides means for controlling cross-sectional profiles. X-radiation in the range 4-10 Å on the other hand is appropriate for replicating patterns in the linewidth range above about 3000 Å, and thus is most appropriate for microelectronic applications (4 - 6).


Author(s):  
Amankwah K.S. ◽  
A.D. Weberg ◽  
R.C. Kaufmann

Previous research has revealed that passive (involuntary inhalation) tobacco smoking during gestation can have adverse effects upon the developing fetus. These prior investigations did not concentrate on changes in fetal morphology. This study was undertaken to delineate fetal neural abnormalities at the ultrastructural level in mice pups exposed in utero to passive maternal smoking.Pregnant study animals, housed in a special chamber, were subjected to cigarette smoke daily from conception until delivery. Blood tests for determination of carbon monoxide levels were run at 15-18 days gestation. Sciatic nerve tissue from experimental and control animals were obtained following spontaneous delivery and fixed in 2.5% gluteraldehyde in 0.1M cacodylate buffer pH 7.3. The samples were post-fixed in osmium ferrocyanide (1:1 mixture of 1.5% aqueous OSO4 and 2.5% K4 Fe(CN)6). Following dehydration, the tissues were infiltrated with and embedded in Spurr. Sections were stained with uranyl acetate and lead citrate.


Author(s):  
R. E. Worsham ◽  
J. E. Mann ◽  
E. G. Richardson

This superconducting microscope, Figure 1, was first operated in May, 1970. The column, which started life as a Siemens Elmiskop I, was modified by removing the objective and intermediate lenses, the specimen chamber, and the complete vacuum system. The large cryostat contains the objective lens and stage. They are attached to the bottom of the 7-liter helium vessel and are surrounded by two vapor-cooled radiation shields.In the initial operational period 5-mm and 2-mm focal length objective lens pole pieces were used giving magnification up to 45000X. Without a stigmator and precision ground pole pieces, a resolution of about 50-100Å was achieved. The boil-off rate of the liquid helium was reduced to 0.2-0.3ℓ/hour after elimination of thermal oscillations in the cryostat. The calculated boil-off was 0.2ℓ/hour. No effect caused by mechanical or electrical instability was found. Both 4.2°K and 1.7-1.9°K operation were routine. Flux pump excitation and control of the lens were quite smooth, simple, and, apparently highly stable. Alignment of the objective lens proved quite awkward, however, with the long-thin epoxy glass posts used for supporting the lens.


Author(s):  
R. F. Zeigel ◽  
W. Munyon

In continuing studies on the role of viruses in biochemical transformation, Dr. Munyon has succeeded in isolating a highly infectious human herpes virus. Fluids of buccal pustular lesions from Sasha Munyon (10 mo. old) uiere introduced into monolayer sheets of human embryonic lung (HEL) cell cultures propagated in Eagles’ medium containing 5% calf serum. After 18 hours the cells exhibited a dramatic C.P.E. (intranuclear vacuoles, peripheral patching of chromatin, intracytoplasmic inclusions). Control HEL cells failed to reflect similar changes. Infected and control HEL cells were scraped from plastic flasks at 18 hrs. of incubation and centrifuged at 1200 × g for 15 min. Resultant cell packs uiere fixed in Dalton's chrome osmium, and post-fixed in aqueous uranyl acetate. Figure 1 illustrates typical hexagonal herpes-type nucleocapsids within the intranuclear virogenic regions. The nucleocapsids are approximately 100 nm in diameter. Nuclear membrane “translocation” (budding) uias observed.


Sign in / Sign up

Export Citation Format

Share Document