scholarly journals Technical evaluation of a solar heating system having conventional hydronic solar collectors and a radiant panel slab. Final report

1984 ◽  
Author(s):  
R.J. Starr
1994 ◽  
Vol 116 (2) ◽  
pp. 88-93 ◽  
Author(s):  
E. Hahne ◽  
M. Hornberger

At Stuttgart University, a solar heating system for an office building with laboratories and lecture rooms was installed in 1985. It consists of 211 m2 of unglazed solar collectors, a 1050 m3 water-flooded pebble bed heat store, and a heat pump. Heat can be supplied to the store from the solar collectors or from a power station (as waste heat). The whole system has worked successfully for five years under varied strategies. In the first two heating periods, the heating strategy was aimed to collect as much solar energy as possible. Thus, about 60 percent of the heat demand could be covered by solar energy; but the yearly heat pump coefficient of performance (COP) was only around 2.76. With an improved heat pump, a monthly COP of 3.6 was obtained. Heat losses from the storage amounted to about 20 percent.


1988 ◽  
Vol 110 (3) ◽  
pp. 172-179 ◽  
Author(s):  
Z. Zhang ◽  
M. Pate ◽  
R. Nelson

An experimental study of a solar-radiant heating system was performed at Iowa State University’s Energy Research House (ERH). The ERH was constructed with copper tubes embedded in the plaster ceilings, thus providing a unqiue radiant heating system. In addition, 24 water-glycol, flat-plate solar collectors were mounted on the south side of the residence. The present study uses the solar collectors to heat a storage tank via a submerged copper tube coil. Hot water from the storage tank is then circulated through a heat exchanger, which heats the water flowing through the radiant ceiling. This paper contains a description of the solar-radiant system and an interpretation of the data that were measured during a series of transient experiments. In addition, the performance of the flat-plate solar collectors and the water storage tank were evaluated. The characteristics of a solar-to-radiant heat exchanger were also investigated. The thermal behavior of the radiant ceiling and the room enclosures were observed, and the heat transfer from the ceiling by radiation and convection was estimated. The overall heating system was also evaluated using the thermal performances of the individual components. The results of this study verify that it is feasible to use a solar system coupled to a low-temperature radiant-panel heating system for space heating. A sample performance evaluation is also presented.


1988 ◽  
Author(s):  
G. Loef ◽  
T. Brisbane ◽  
B. Coughlan ◽  
H. Walker ◽  
J. Davidson