Commercial sector energy consumption: analysis and recommendations for data collection. Final report

1977 ◽  
Author(s):  
Not Given Author
2020 ◽  
Vol 10 (1) ◽  
pp. 327
Author(s):  
Francisco Vázquez-Gallego ◽  
Pere Tuset-Peiró ◽  
Luis Alonso ◽  
Jesus Alonso-Zarate

This paper models and evaluates three FSA-based (Frame Slotted ALOHA) MAC (Medium Access Control) protocols, namely, FSA-ACK (FSA with ACKnowledgements), FSA-FBP (FSA with FeedBack Packets) and DFSA (Dynamic FSA). The protocols are modeled using an AMC (Absorbing Markov Chain), which allows to derive analytic expressions for the average packet delay, as well as the energy consumption of both the network coordinator and the end-devices. The results, based on computer simulations, show that the analytic model is accurate and outline the benefits of DFSA. In terms of delay, DFSA provides a reduction of 17% (FSA-FBP) and 32% (FSA-ACK), whereas in terms of energy consumption DFSA provides savings of 23% (FSA-FBP) and 28% (FSA-ACK) for the coordinator and savings of 50% (FSA-FBP) and 24% (FSA-ACK) for end-devices. Finally, the paper provides insights on how to configure each FSA variant depending on the network parameters, i.e., depending on the number of end-devices, to minimize delay and energy expenditure. This is specially interesting for massive data collection in IoT (Internet-of-Things) scenarios, which typically rely on FSA-based protocols and where the operation has to be optimized to support a large number of devices with stringent energy consumption requirements.


Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1800
Author(s):  
Linfei Hou ◽  
Fengyu Zhou ◽  
Kiwan Kim ◽  
Liang Zhang

The four-wheeled Mecanum robot is widely used in various industries due to its maneuverability and strong load capacity, which is suitable for performing precise transportation tasks in a narrow environment. While the Mecanum wheel robot has mobility, it also consumes more energy than ordinary robots. The power consumed by the Mecanum wheel mobile robot varies enormously depending on their operating regimes and environments. Therefore, only knowing the working environment of the robot and the accurate power consumption model can we accurately predict the power consumption of the robot. In order to increase the applicable scenarios of energy consumption modeling for Mecanum wheel robots and improve the accuracy of energy consumption modeling, this paper focuses on various factors that affect the energy consumption of the Mecanum wheel robot, such as motor temperature, terrain, the center of gravity position, etc. The model is derived from the kinematic and kinetic model combined with electrical engineering and energy flow principles. The model has been simulated in MATLAB and experimentally validated with the four-wheeled Mecanum robot platform in our lab. Experimental results show that the accuracy of the model reached 95%. The results of energy consumption modeling can help robots save energy by helping them to perform rational path planning and task planning.


Energies ◽  
2019 ◽  
Vol 12 (19) ◽  
pp. 3775 ◽  
Author(s):  
Khaled Bawaneh ◽  
Farnaz Ghazi Nezami ◽  
Md. Rasheduzzaman ◽  
Brad Deken

Healthcare facilities in the United States account for 4.8% of the total area in the commercial sector and are responsible for 10.3% of total energy consumption in this sector. The number of healthcare facilities increased by 22% since 2003, leading to a 21% rise in energy consumption and an 8% reduction in energy intensity per unit of area (544.8 kWh/m2). This study provides an analytical overview of the end-use energy consumption data in healthcare systems for hospitals in the United States. The energy intensity of the U.S. hospitals ranges from 640.7 kWh/m2 in Zone 5 (very hot) to 781.1 kWh/m2 in Zone 1 (very cold), with an average of 738.5 kWh/m2. This is approximately 2.6 times higher than that of other commercial buildings. High energy intensity in the healthcare facilities, particularly in hospitals, along with energy costs and associated environmental concerns make energy analysis crucial for this type of facility. The proposed analysis shows that U.S. healthcare facilities have higher energy intensity than those of most other countries, especially the European ones. This necessitates the adoption of more energy-efficient approaches to the infrastructure and the management of healthcare facilities in the United States.


2017 ◽  
Vol 90 (8-9) ◽  
pp. 1191-1204 ◽  
Author(s):  
Ping Wang ◽  
Jing Liu ◽  
Jinlong Lin ◽  
Chao-Hsien Chu

Sign in / Sign up

Export Citation Format

Share Document