scholarly journals Single tube hydride heat exchanger test facility

1979 ◽  
Author(s):  
H.P. Egbert ◽  
J.S. Horowitz ◽  
G.M. Warapius
1983 ◽  
Vol 105 (2) ◽  
pp. 348-353 ◽  
Author(s):  
D. E. Wright ◽  
L. L. Tignac

Rocketdyne is under contract to the Department of Energy for the development of heat exchanger technology that will allow coal to be burned for power generation and cogeneration applications. This effort involves both atmospheric fluidized bed and pulverized coal combustion systems. In addition, the heat exchanger designs cover both metallic and ceramic materials for high-temperature operations. This paper reports on the laboratory and small AFB test results completed to date. It also covers the design and installation of a 6×6 ft atmospheric fluidized bed test facility being used to correlate and expand the knowledge gained from the initial tests. The paper concludes by showing the direction this technology is taking and outlining the steps to follow in subsequent programs.


Energies ◽  
2019 ◽  
Vol 12 (17) ◽  
pp. 3276 ◽  
Author(s):  
Jan Wajs ◽  
Michał Bajor ◽  
Dariusz Mikielewicz

In this paper a patented design of a heat exchanger with minijets, with a cylindrical construction is presented. It is followed by the results of its systematic experimental investigations in the single-phase convection heat transfer mode. Based on these results, validation of selected correlations (coming from the literature) describing the Nusselt number was carried out. An assessment of the heat exchange intensification level in the described heat exchanger was done through the comparison with a shell-and-tube exchanger of a classical design. The thermal-hydraulic characteristics of both units were the subjects of comparison. They were constructed for the identical thermal conditions, i.e., volumetric flow rates of the working media and the media temperatures at the inlets to the heat exchanger. The experimental studies of both heat exchangers were conducted on the same test facility. An increase in the heat transfer coefficients values for the minijets heat exchanger was observed in comparison with the reference one, whereas the generated minijets caused greater hydraulic resistance. Experimentally confirmed intensification of heat transfer on the air side, makes the proposed minijets heat exchanger application more attractive, for the waste heat utilization systems from gas sources.


Author(s):  
Byoung-Uhn Bae ◽  
Seok Kim ◽  
Yu-Sun Park ◽  
Bok-Deuk Kim ◽  
Kyoung-Ho Kang ◽  
...  

The Passive Auxiliary Feedwater System (PAFS) is one of the advanced safety features adopted in the APR+ (Advanced Power Reactor Plus) which is intended to completely replace the conventional active auxiliary feedwater system. It removes the decay heat by cooling down the secondary system of the SG using condensation heat exchanger installed in the Passive Condensation Cooling Tank (PCCT). With an aim of validating the cooling and operational performance of the PAFS, PASCAL (PAFS Condensing Heat Removal Assessment Loop), was constructed to experimentally investigate the condensation heat transfer and natural convection phenomena in the PAFS. It simulates a single tube of the passive condensation heat exchangers, a steam-supply line, a return-water line, and a PCCT with a reduced area, which is equivalent to 1/240 of the prototype according to a volumetric scaling methodology with a full height. The objective of the experiment is to investigate the cooling performance and natural circulation characteristics of the PAFS by simulating a steady state condition of the thermal power. From the experiment, two-phase flow phenomena in the horizontal heat exchanger and PCCT were investigated and the cooling capability of the condensation heat exchanger was validated. Test results showed that the design of the condensation heat exchanger in PAFS could satisfy the requirement for heat removal rate of 540 kW per a single tube and the prevention of water hammer phenomenon inside the tube. It also proved that the operation of PAFS played an important role in cooling down the decay heat by natural convection without any active system. The present experimental results will contribute to improve the model of the condensation and boiling heat transfer, and also to provide the benchmark data for validating the calculation performance of a thermal hydraulic system analysis code with respect to the PAFS.


2011 ◽  
Vol 19 (02) ◽  
pp. 107-112 ◽  
Author(s):  
GEYDY GUTIÉRREZ URUETA ◽  
PEDRO RODRÍGUEZ AUMENTE ◽  
MARIA RODRÍGUEZ HIDALGO ◽  
ANTONIO LECUONA NEUMANN

This work analyzes the effect that particular operating conditions of a single effect H2O - LiBr adiabatic absorption system have on a plate-type solution heat exchanger efficiency. The corresponding influence of such efficiency on the performance of facility under study is evaluated. As a result of the design of experimental test facility, the functioning of the strong solution circuit leads to take into account some particular operating conditions which affect the correct performance of the solution heat exchanger. For some experimental conditions, the strong solution side is not completely filled by the solution fluid. As a consequence of this, the heat transfer process is affected, reducing the solution heat exchanger efficiency and changing greatly the resulting coefficient of performance (COP) of the absorption facility. In order to illustrate this phenomenon, this paper offers graphical results including: solution working temperatures, solution heat exchanger efficiency and COP in a time sequence of an experiment, as well as for fixed steady-state operating conditions. These results show the importance of a correct functioning of the solution heat exchanger on the performance of an absorption system. The results are useful for researchers interested in new absorption cycle designs.


Author(s):  
A. V. Morozov ◽  
O. V. Remizov ◽  
A. A. Tsyganok

The experimental investigations of non-condensable gases effect on the steam condensation inside multirow horizontal tube bundle of heat exchanger under heat transfer to boiling water were carried out at the large-scale test facility in the Institute for Physics and Power Engineering (IPPE). The experiments were carried out for natural circulation conditions in primary and secondary circuits of the facility at primary circuit steam pressure of Ps1 = 0.34 MPa. The experimental heat exchanger’s tube bundle consists of 248 horizontal coiled tubes arranged in 62 rows. Each row consists of 4 stainless steel tubes of 16 mm in outer diameter, 1.5 mm in wall thickness and of 10.2 m in length. The experimental heat exchanger was equipped with more than 100 thermocouples enabling the temperatures of primary and secondary facility circuits to be controlled in both tube bundle and in the inter-tubular space. The non-condensable gases with different density — nitrogen and helium were used in the experiments. The volumetric content of gases in tube bundle amounted to ε = 0.49. The empirical correlation for the prediction of the relative heat transfer coefficient k/k0 = f (ε) for steam condensation in steam-gas mixture was obtained.


Author(s):  
Wolfgang Flaig ◽  
Rainer Mertz ◽  
Joerg Starflinger

Supercritical fluids show great potential as future coolants for nuclear reactors, thermal power, and solar power plants. Compared to the subcritical condition, supercritical fluids show advantages in heat transfer due to thermodynamic properties near the critical point. A specific field of interest is an innovative decay heat removal system for nuclear power plants, which is based on a turbine-compressor system with supercritical CO2 as the working fluid. In case of a severe accident, this system converts the decay heat into excess electricity and low-temperature waste heat, which can be emitted to the ambient air. To guarantee the retrofitting of this decay heat removal system into existing nuclear power plants, the heat exchanger (HE) needs to be as compact and efficient as possible. Therefore, a diffusion-bonded plate heat exchanger (DBHE) with mini channels was developed and manufactured. This DBHE was tested to gain data of the transferable heat power and the pressure loss. A multipurpose facility has been built at Institut für Kernenergetik und Energiesysteme (IKE) for various experimental investigations on supercritical CO2, which is in operation now. It consists of a closed loop where the CO2 is compressed to supercritical state and delivered to a test section in which the experiments are run. The test facility is designed to carry out experimental investigations with CO2 mass flows up to 0.111 kg/s, pressures up to 12 MPa, and temperatures up to 150 °C. This paper describes the development and setup of the facility as well as the first experimental investigation.


2020 ◽  
Vol 178 ◽  
pp. 01026
Author(s):  
Natalia Rydalina ◽  
Oleg Stepanov ◽  
Elena Antonova

Heat exchangers are widely used in heat supply systems. To increase the efficiency of heat supply systems, heat exchangers with porous metals are proposed to design. There was a test facility set up to study new types of heat exchangers. The countercurrent flow of heat carriers was activated in those heat exchangers. Freon moved through the heat exchanger pores, and water moved through the inner tubes. It should be noted that the porous materials in the heat exchangers differed in the coefficient of porosity. To be compared, one of the heat exchangers did not contain any porous material. The first test cycle proved the feasibility of using porous metals in heat exchange equipment. Afterwards, a simplified mathematical model of the heat exchanger was compiled. Such an analytical form makes a solution convenient for engineering calculations. Numerical calculations based on this model were compared with the experimental data. Heat transfer intensity of materials with different porosity was compared.


Author(s):  
Seon-hwa Kim ◽  
Jae-jun Lee ◽  
Young-min Oh ◽  
Sang-hoon Lee ◽  
Jae-sik Kim

The MCFC system of BOP (Balance of Plant) is contained various mechanical equipments. One of the equipments of the heat exchangers is important component for efficiency and cost. In MCFC system, several heat exchangers are used according to the application. Most typical heat exchanger is the humidifier in BOP for MCFC, which is named for the humidifier because it is to preheat the fuel and water so that a reactor will convert some of the incoming fuel to hydrogen. Then, hot side fluid service is used the exhausted gas from the fuel cell and cold side fluid service is the fuel and water. The operation temperature range is about 25∼500 Celsius Degree.[1] This heat exchanger has the problems of multiphase fluid and phase change heat transfer. So it is necessary to analyze the heat transfer characteristics and to propose the reasonable design methodology for the humidifier. In this study, the thermal characteristic for the humidifier is estimated by using commercial tool of heat exchanger design, rating and simulation. Also this study presents the results for test facility of fabrication and for testing.


Sign in / Sign up

Export Citation Format

Share Document