Determination of freeze-protection heat loss from a parabolic trough solar system

1983 ◽  
Author(s):  
E. May
1984 ◽  
Vol 106 (2) ◽  
pp. 233-234
Author(s):  
E. K. May

The thermal energy required to prevent the freezing of water in an industrial parabolic trough solar system is quantified. Even in a cold climate, such as that of Denver, Colorado, thermal losses can be much less than 1 percent of the solar energy delivery.


Author(s):  
O. Mousis ◽  
D. H. Atkinson ◽  
R. Ambrosi ◽  
S. Atreya ◽  
D. Banfield ◽  
...  

AbstractRemote sensing observations suffer significant limitations when used to study the bulk atmospheric composition of the giant planets of our Solar System. This impacts our knowledge of the formation of these planets and the physics of their atmospheres. A remarkable example of the superiority of in situ probe measurements was illustrated by the exploration of Jupiter, where key measurements such as the determination of the noble gases’ abundances and the precise measurement of the helium mixing ratio were only made available through in situ measurements by the Galileo probe. Here we describe the main scientific goals to be addressed by the future in situ exploration of Saturn, Uranus, and Neptune, placing the Galileo probe exploration of Jupiter in a broader context. An atmospheric entry probe targeting the 10-bar level would yield insight into two broad themes: i) the formation history of the giant planets and that of the Solar System, and ii) the processes at play in planetary atmospheres. The probe would descend under parachute to measure composition, structure, and dynamics, with data returned to Earth using a Carrier Relay Spacecraft as a relay station. An atmospheric probe could represent a significant ESA contribution to a future NASA New Frontiers or flagship mission to be launched toward Saturn, Uranus, and/or Neptune.


2020 ◽  
Vol 15 (4) ◽  
pp. 613-619
Author(s):  
Li Kong ◽  
Yunpeng Zhang ◽  
Zhijian Lin ◽  
Zhongzhu Qiu ◽  
Chunying Li ◽  
...  

Abstract The present work aimed to select the optimum solar tracking mode for parabolic trough concentrating collectors using numerical simulation. The current work involved: (1) the calculation of daily solar radiation on the Earth’s surface, (2) the comparison of annual direct solar radiation received under different tracking modes and (3) the determination of optimum tilt angle for the north-south tilt tracking mode. It was found that the order of solar radiation received in Shanghai under the available tracking modes was: dual-axis tracking > north-south Earth’s axis tracking > north-south tilt tracking (β = 15°) > north-south tilt tracking (β = 45) > north-south horizontal tracking > east-west horizontal tracking. Single-axis solar tracking modes feature simple structures and low cost. This study also found that the solar radiation received under the north-south tilt tracking mode was higher than that of the north-south Earth’s axis tracking mode in 7 out of 12 months. Therefore, the north-south tilt tracking mode was studied separately to determine the corresponding optimum tilt angles in Haikou, Lhasa, Shanghai, Beijing and Hohhot, respectively, which were shown as follows: 18.81°, 27.29°, 28.67°, 36.21° and 37.97°.


2021 ◽  
Vol 4 (164) ◽  
pp. 77-81
Author(s):  
Yu. Ivashina ◽  
V. Zavodyannyi

To calculate the share of thermal energy consumed by this apartment in an apartment building, it is necessary to determine the heat transfer of all heating radiators in the house. But the heat transfer given in the passport of the heating device corresponds to the temperature pressure equal to 70K. Often the owners install non-standard devices, so the problem of determining the heat transfer of heating radiators in real conditions is relevant. Thermometric method, which is called electric, is widely used for laboratory determination of heat transfer of heating devices. Water by means of the pump circulates through an electric copper and the investigated radiator. The heat output of the latter is defined as the difference between the supplied electrical power (boiler power plus pump) and heat loss. The purpose of the work is to develop and study the operation of the installation for determining the heat transfer of heating radiators, which had a simpler design and could ensure proper measurement accuracy. We have proposed a scheme and design of the installation for determining the heat transfer of electric heating radiators, which differs in that it does not include a circulating pump. Water in the system circulates under the action of gravity due to changes in the density of the coolant during heating and cooling. This greatly simplifies the circuit by eliminating not only the pump but also the valve and the air outlet valve. The heater chamber is made of a steel pipe with a diameter of 88 mm. A steel cover is attached to the lower flange, through which a 1-1.5 kW heater is introduced into the chamber. Two 1/2 ″ sections of pipe are welded to the body of the heater chamber, through which the radiator is connected by means of rubber couplings. The cylindrical surface of the chamber on top of the layer of internal insulation is covered with a shielding heater, the temperature of which is maintained equal to the surface temperature of the heater chamber in the middle part. A layer of external thermal insulation is installed on top of the shielding heater. To determine heat loss, the radiator is disconnected from the heater chamber, plugs are installed and insulated. In stationary mode, the dependence of the heater power on the temperature of the heater chamber is measured, which determines the power of heat losses. The simplification of the installation has led not only to its reduction in price, but also to an increase in accuracy due to the reduction of heat losses and the simplicity of their definition.


1982 ◽  
Vol 22 (04) ◽  
pp. 558-562 ◽  
Author(s):  
P.C. Rawat ◽  
S.L. Agarwal

Abstract An important parameter required for computing heat loss through buried submarine pipelines transporting crude oil is the thermal conductivity of soils. This paper describes an apparatus designed for determination of the thermal conductivity of soils at the desired moisture/ density condition in the laboratory under steady-state conditions. Experimental results on the three soils studied show that thermal conductivity increases as dry density increases at a constant moisture content and that it increases as water content increases at constant dry density. These results confirm the trends isolated earlier by Kersten. The experimental results are compared with the available empirical relationships. Kersten's relation is observed to predict the thermal conductivity of these soils reasonably. The predictions from Makowski and Mochlinski's relation (quoted by Szilas) are not good but improve if the sum of silt and clay fractions is treated as a clay fraction in the computation. Introduction Submarine pipelines are used extensively for transporting crude oil from offshore to other pipelines offshore or onshore. These pipelines usually are steel pipes covered with a coating of concrete. They often are buried some depth below the mudline. The rheological properties of different crude oils vary, and their viscosities increase with a decrease in temperature. Below some temperature, the liquid oil tends to gel. Therefore, for efficient transportation, the crude must be at a relatively high temperature so that it has a low viscosity. The temperature of the soil/water system surrounding a submarine pipeline is usually lower than that of oil. This temperature difference induces heat to flow from the oil to the environment, and the temperature of the oil decreases as it travels along the length of the pipeline. One must ensure that this temperature reduction does not exceed desirable limits dictated by the rheological properties of oil and by the imperatives of efficient economic properties of oil and by the imperatives of efficient economic transportation. Thus the analytical problem is to predict the temperature of crude in the pipeline some distance away from the input station. To do so, knowledge of the overall heat transfer coefficient for the pipeline is required, for which, in turn, it is necessary to know the thermal conductivities of the oil, the pipeline materials and its coating, and the soil. This paper presents thermal conductivities of soils determined in the laboratory under steady-state conditions and also presents a comparison of the test results of three soils with values determined from existing empirical relationships. Literature Review Heat moves spontaneously from higher to lower temperatures. In a completely dry porous body, transmission of heat can take place not only by conduction through the solid framework of the body and the air in the pores but also by convection and radiation between the walls of a pore and by macro- and microdistillation. In soils, however, it can be ascribed essentially to conduction, a molecular phenomenon that can be expressed in terms of experimentally determined coefficients of conductivity or resistivity, although these actually may include microdistillation and other mechanisms. SPEJ p. 558


1968 ◽  
Vol 1 (4) ◽  
pp. 154-157
Author(s):  
D. J. Cooke ◽  
A. G. Fenton

Primary cosmic rays passing through the solar system carry with them valuable information about solar and astrophysical phenomena in the form of intensity and spectral variations. In order that this information be efficiently extracted from observations of the directional cosmic-ray flux at the surface of the Earth, it is essential to have accurate information available to enable the relating of the observed secondary cosmic-ray directions of motion and intensity to those outside the range of the disturbing terrestrial influences.


Sign in / Sign up

Export Citation Format

Share Document