scholarly journals High resolution positron Q-value measurements and nuclear structure studies far from the stability line. Progress report

1982 ◽  
Author(s):  
F.T. III Avignone
Author(s):  
Mihir Parikh

It is well known that the resolution of bio-molecules in a high resolution electron microscope depends not just on the physical resolving power of the instrument, but also on the stability of these molecules under the electron beam. Experimentally, the damage to the bio-molecules is commo ly monitored by the decrease in the intensity of the diffraction pattern, or more quantitatively by the decrease in the peaks of an energy loss spectrum. In the latter case the exposure, EC, to decrease the peak intensity from IO to I’O can be related to the molecular dissociation cross-section, σD, by EC = ℓn(IO /I’O) /ℓD. Qu ntitative data on damage cross-sections are just being reported, However, the microscopist needs to know the explicit dependence of damage on: (1) the molecular properties, (2) the density and characteristics of the molecular film and that of the support film, if any, (3) the temperature of the molecular film and (4) certain characteristics of the electron microscope used


2021 ◽  
Vol 104 (1) ◽  
Author(s):  
A. V. Voinov ◽  
K. Brandenburg ◽  
C. R. Brune ◽  
R. Giri ◽  
S. M. Grimes ◽  
...  

2021 ◽  
Author(s):  
Maximillian Van Wyk de Vries ◽  
Shashank Bhushan ◽  
David Shean ◽  
Etienne Berthier ◽  
César Deschamps-Berger ◽  
...  

<p>On the 7<sup>th</sup> of February 2021, a large rock-ice avalanche triggered a debris flow in Chamoli district, Uttarakhand, India, resulting in over 200 dead or missing and widespread infrastructure damage. The rock-ice avalanche originated from a steep, glacierized north-facing slope with a history of instability, most recently a 2016 ice avalanche. In this work, we assess whether the slope exhibited any precursory displacement prior to collapse. We evaluate monthly slope motion over the 2015 and 2021 period through feature tracking of high-resolution optical satellite imagery from Sentinel-2 (10 m Ground Sampling Distance) and PlanetScope (3-4 m Ground Sampling Distance). Assessing slope displacement of the underlying rock is complicated by the presence of glaciers over a portion of the collapse area, which display surface displacements due to internal ice deformation. We overcome this through tracking the motion over ice-free portions of the slide area, and evaluating the spatial pattern of velocity changes in glaciated areas. Preliminary results show that the rock-ice avalanche bloc slipped over 10 m in the 5 years prior to collapse, with particularly rapid slip occurring in the summer of 2017 and 2018. These results provide insight into the precursory conditions of the deadly rock-ice avalanche, and highlight the potential of high-resolution optical satellite image feature tracking for monitoring the stability of high-risk slopes.</p>


2020 ◽  
Author(s):  
Mathieu Tiquet ◽  
Raphaël La Rocca ◽  
Daan van Kruining ◽  
Pilar Martinez-Martinez ◽  
Gauthier Eppe ◽  
...  

<p><i>MALDI mass spectrometry imaging (MSI) is a powerful analytical method giving access to the 2D localizations of compounds in a thin section of a sample. To properly discern isobaric compounds in complex biological samples, dynamically harmonized ICR cell (ParaCell©) has been introduce to achieve extreme spectral resolution. However, high resolution MS images realized on a 9.4T FTICR High resolution instrument with recommended parameters suffered from an abnormal shifting of m/z ratios pixel to pixel. Resulting datasets show poor mass accuracy measurements and resolutions under estimations. By following the behavior of the Total Ion Current in function of the number of laser shots, the abnormal mass shifting phenomenon has been linked to the stability of the Total Ion Current (TIC) during images acquisitions. An optimization of laser parameters is proposed in order to limit the observed mass shift to retain machine specifications during MSI analyses. It is also shown that the method has been successfully employed to realize quality MS images with resolution above 1,000,000 in the lipid mass range across the whole image.</i></p>


Sign in / Sign up

Export Citation Format

Share Document