scholarly journals THERMAL DETECTION METHOD FOR EXTREME ENVIRONMENTS. Quarterly Progress Report No. 1, April 1-June 30, 1964

1965 ◽  
Author(s):  
G. Kalon
2021 ◽  
Author(s):  
Juan Tang ◽  
Liping Liu ◽  
Shan Gao ◽  
Jiao Qin ◽  
Xiaoxuan Liu ◽  
...  

A simple thermal aptasensing platform was devised for sensitive detection of organophosphate pesticides (malathion as a model target) based on the efficient self-heating reaction of a warm pad with a...


Author(s):  
Shudan Wang ◽  
Mingzhi Guan ◽  
Jiaxiang Chen ◽  
Xingzhe Wang ◽  
You-He Zhou

Abstract A fast and effective quench detection method is especially challenging in the development of high-field high-temperature superconducting (HTS) magnets for their safe operations and reliably releasing the stored energy during a quench. The occurrence and propagation of a quench are often accompanied by strong thermal and magneto-mechanical responses within superconducting magnets. Aiming to detect a quench in the whole process and capture the thermoelastic behavior associated with it, a new detection technique with a visual and full-field perception based on the digital image correlation (DIC) method is proposed in the present study. The experiment of a quench triggered thermally by a local spot heater is conducted for a YBCO coated conductor tape in a cryogenic chamber. The evolution and characteristics of the full-field strain in the HTS tape during the processes of a non-quench, a quench occurrence and quench propagation are intuitively presented with experimental observations. For the comparison purpose, the conventional quench detection methods by monitoring temperature and voltage signals during a quench are also utilized experimentally. The results verify the visual and full-field quench detection method which uses a criterion of thermoelastic strain-rate for the quench occurrence and the evolution of strain contours for the normal zone propagating aspect. Additionally, a numerical quench model of coupled thermoelasticity to simulate the experiment is established and solved with the aid of Comsol multiphysics software. The quantitative results are in good agreement with the experimental measurements to prove the reliability and availability of the developed detection method. Since the DIC method is non-contact and insensitivity to intense electromagnetic interferences, it is expected to provide a new technique on quench issues and some basic measurements on strain/stress behaviors in extreme environments of high-field HTS magnets in the future.


Nanoscale ◽  
2018 ◽  
Vol 10 (4) ◽  
pp. 2081-2089 ◽  
Author(s):  
Francesco Canfarotta ◽  
J. Czulak ◽  
K. Betlem ◽  
A. Sachdeva ◽  
K. Eersels ◽  
...  

A novel thermal sensor based on nanoparticles as recognition elements with great potential for in vivo detection of a range of targets.


1966 ◽  
Vol 24 ◽  
pp. 118-119
Author(s):  
Th. Schmidt-Kaler

I should like to give you a very condensed progress report on some spectrophotometric measurements of objective-prism spectra made in collaboration with H. Leicher at Bonn. The procedure used is almost completely automatic. The measurements are made with the help of a semi-automatic fully digitized registering microphotometer constructed by Hög-Hamburg. The reductions are carried out with the aid of a number of interconnected programmes written for the computer IBM 7090, beginning with the output of the photometer in the form of punched cards and ending with the printing-out of the final two-dimensional classifications.


1967 ◽  
Vol 31 ◽  
pp. 177-179
Author(s):  
W. W. Shane

In the course of several 21-cm observing programmes being carried out by the Leiden Observatory with the 25-meter telescope at Dwingeloo, a fairly complete, though inhomogeneous, survey of the regionl11= 0° to 66° at low galactic latitudes is becoming available. The essential data on this survey are presented in Table 1. Oort (1967) has given a preliminary report on the first and third investigations. The third is discussed briefly by Kerr in his introductory lecture on the galactic centre region (Paper 42). Burton (1966) has published provisional results of the fifth investigation, and I have discussed the sixth in Paper 19. All of the observations listed in the table have been completed, but we plan to extend investigation 3 to a much finer grid of positions.


Author(s):  
K. Pegg-Feige ◽  
F. W. Doane

Immunoelectron microscopy (IEM) applied to rapid virus diagnosis offers a more sensitive detection method than direct electron microscopy (DEM), and can also be used to serotype viruses. One of several IEM techniques is that introduced by Derrick in 1972, in which antiviral antibody is attached to the support film of an EM specimen grid. Originally developed for plant viruses, it has recently been applied to several animal viruses, especially rotaviruses. We have investigated the use of this solid phase IEM technique (SPIEM) in detecting and identifying enteroviruses (in the form of crude cell culture isolates), and have compared it with a modified “SPIEM-SPA” method in which grids are coated with protein A from Staphylococcus aureus prior to exposure to antiserum.


1998 ◽  
Vol 23 (2) ◽  
pp. 187-187
Author(s):  
Verkerke ◽  
Schutte ◽  
Mahieu ◽  
Van Den Hoogen ◽  
De Vries ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document