scholarly journals Removal of antibiotic resistant E. coli in two Norwegian wastewater treatment plants and by nano- and ultra-filtration processes

2017 ◽  
Vol 77 (4) ◽  
pp. 1115-1126 ◽  
Author(s):  
Carsten Ulrich Schwermer ◽  
Pawel Krzeminski ◽  
Aina Charlotte Wennberg ◽  
Christian Vogelsang ◽  
Wolfgang Uhl

Abstract The effectivity of different treatment stages at two large wastewater treatment plants (WWTPs) located in Oslo, Norway, to remove antibiotic resistant Escherichia coli from municipal wastewater was investigated. The WWTPs were effective in reducing the total cultivable E. coli. The E. coli in WWTP samples were mainly resistant to ampicillin (6–27%) and trimethoprim-sulfamethoxazole (5–24%), and, to a lesser extent, tetracycline (3–14%) and ciprofloxacin (0–7%). In the first WWTP, a clear decrease in the percentage of E. coli resistant to these antibiotics was found, with the main removal occurring during physical/chemical treatment. In the second WWTP, the percentage of cultivable resistant E. coli did not display a considerable change. During laboratory-scale membrane filtration of WWTP effluents using ultrafiltration (UF) and nanofiltration (NF) membranes, all E. coli, including those resistant to antibiotics, were removed completely. The results imply that UF and NF processes are potent measures to remove antibiotic resistant bacteria (ARB) during post-treatment of WWTP effluents, thus reducing the potential spread of antibiotic resistance in the receiving aquatic environment.

2019 ◽  
Vol 100 ◽  
pp. 00061 ◽  
Author(s):  
Adriana Osińska ◽  
Ewa Korzeniewska ◽  
Monika Harnisz ◽  
Sebastian Niestępski ◽  
Piotr Jachimowicz

Wastewater treatment plants (WWTPs) are major reservoirs of antibiotic-resistant bacteria (ARB) which are transported to the natural environment with discharged effluents. Samples of untreated wastewater (UWW) and treated wastewater (TWW) from four municipal WWTPs and samples of river water collected upstream (URW) and downstream (DRW) from the effluent discharge point were analyzed in the study. The total counts of bacteria resistant to β-lactams and tetracyclines and the counts of antibiotic-resistant Escherichia coli were determined. Antibiotic-resistant bacteria, including antibiotic-resistant E. coli, were removed with up to 99.9% efficiency in the evaluated WWTPs. Despite the above, ARB counts in TWW samples were high at up to 1.25x105 CFU/mL in winter and 1.25x103 CFU/mL in summer. Antibiotic-resistant bacteria were also abundant (up to 103 CFU/ml) in URW and DRW samples collected in winter and summer. In both UWW and TWW samples, the counts of ARB and antibiotic-resistant E. coli were at least one order of magnitude lower in summer than in winter. The study revealed that despite the high efficiency of bacterial removal in the wastewater treatment processes, considerable amounts of ARB are released into the environment with TWW and that the percentage of ARB in total bacterial counts increases after wastewater treatment.


Antibiotics ◽  
2021 ◽  
Vol 10 (9) ◽  
pp. 1070
Author(s):  
Tomáš Mackuľak ◽  
Klára Cverenkárová ◽  
Andrea Vojs Staňová ◽  
Miroslav Fehér ◽  
Michal Tamáš ◽  
...  

Municipal wastewaters can generally provide real-time information on drug consumption, the incidence of specific diseases, or establish exposure to certain agents and determine some lifestyle consequences. From this point of view, wastewater-based epidemiology represents a modern diagnostic tool for describing the health status of a certain part of the population in a specific region. Hospital wastewater is a complex mixture of pharmaceuticals, illegal drugs, and their metabolites as well as different susceptible and antibiotic-resistant microorganisms, including viruses. Many studies pointed out that wastewater from healthcare facilities (including hospital wastewater), significantly contributes to higher loads of micropollutants, including bacteria and viruses, in municipal wastewater. In addition, such a mixture can increase the selective pressure on bacteria, thus contributing to the development and dissemination of antimicrobial resistance. Because many pharmaceuticals, drugs, and microorganisms can pass through wastewater treatment plants without any significant change in their structure and toxicity and enter surface waters, treatment technologies need to be improved. This short review summarizes the recent knowledge from studies on micropollutants, pathogens, antibiotic-resistant bacteria, and viruses (including SARS-CoV-2) in wastewater from healthcare facilities. It also proposes several possibilities for improving the wastewater treatment process in terms of efficiency as well as economy.


Author(s):  
Maria Clara V. M. Starling ◽  
Elizângela P. Costa ◽  
Felipe A. Souza ◽  
Elayne C. Machado ◽  
Juliana Calábria de Araujo ◽  
...  

AbstractThis work investigated an innovative alternative to improve municipal wastewater treatment plant effluent (MWWTP effluent) quality aiming at the removal of contaminants of emerging concern (caffeine, carbendazim, and losartan potassium), and antibiotic-resistant bacteria (ARB), as well as disinfection (E. coli). Persulfate was used as an alternative oxidant in the solar photo-Fenton process (solar/Fe/S2O82−) due to its greater stability in the presence of matrix components. The efficiency of solar/Fe/S2O82− at neutral pH using intermittent iron additions is unprecedented in the literature. At first, solar/Fe/S2O82− was performed in a solar simulator (30 W m−2) leading to more than 60% removal of CECs, and the intermittent iron addition strategy was proved effective. Then, solar/Fe/S2O82− and solar/Fe/H2O2 were compared in semi-pilot scale in a raceway pond reactor (RPR) and a cost analysis was performed. Solar/Fe/S2O82− showed higher efficiencies of removal of target CECs (55%), E. coli (3 log units), and ARB (3 to 4 log units) within 1.9 kJ L−1 of accumulated irradiation compared to solar/Fe/H2O2 (CECs, 49%; E. coli, 2 log units; ARB, 1 to 3 log units in 2.5 kJ L−1). None of the treatments generated acute toxicity upon Allivibrio fischeri. Lower total cost was obtained using S2O82− (0.6 € m−3) compared to H2O2 (1.2 € m−3). Therefore, the iron intermittent addition aligned to the use of persulfate is suitable for MWWTP effluent quality improvement at neutral pH.


Antibiotics ◽  
2021 ◽  
Vol 10 (6) ◽  
pp. 684
Author(s):  
Sofia Svebrant ◽  
Robert Spörndly ◽  
Richard H. Lindberg ◽  
Therese Olsen Sköldstam ◽  
Jim Larsson ◽  
...  

Hospital sewage constitutes an important point source for antibiotics and antibiotic-resistant bacteria due to the high antibiotic use. Antibiotic resistance can develop and cause problems in sewage systems within hospitals and municipal wastewater treatment plants, thus, interventions to treat hospital sewage on-site are important. Ozonation has proven effective in treating relatively clean wastewater, but the effect on untreated wastewater is unclear. Therefore, we piloted implementation of ozonation to treat wastewater in a tertiary hospital in Uppsala, Sweden. We measured active pharmaceutical ingredients (APIs) using liquid chromatography-mass spectrometry and antibiotic-resistant Enterobacteriaceae using selective culturing pre- and post-ozonation. Comparing low (1 m3/h) and high (2 m3/h) flow, we obtained a ‘dose-dependent’ effect of API reduction (significant reduction of 12/29 APIs using low and 2/29 APIs using high flow, and a mean reduction of antibiotics of 41% using low vs. 6% using high flow, 25% vs. 6% for all APIs). There was no significant difference in the amount of antibiotic-resistant Enterobacteiaceae pre- and post-ozonation. Our results demonstrate that ozonation of untreated wastewater can reduce API content. However, due to the moderate API decrease and numerous practical challenges in the on-site setting, this specific ozonation system is not suitable to implement at full scale in our hospital.


2018 ◽  
Vol 45 ◽  
pp. 00054 ◽  
Author(s):  
Bozena Mrowiec

The aim of this paper was to review the literature data regarding the physico-chemical characteristic of plastic pollutants discharged with municipal sewage, the practical possibility of removing microplastic particles from wastewater during different treatment steps in WWTPs and the problem of surface water contamination within them. Microplastics (the size range of 1 nm to < 5 mm), have been recognized as an emerging threat, as well as an ecotoxicological and ecological risk for water ecosystems. Municipal wastewater treatment plants (WWTPs) are mentioned as the main point sources of microplastics in an aquatic environment. Microplastic particles can be effectively removed in the primary treatment zones via solids skimming and sludge settling processes. Different tertiary treatment processes such as: gravity sand filtration, discfilter, air flotation and membrane filtration provide substantial additional removal of microplastics, and the efficiency of wastewater treatment process can be at a removal level of 99.9%. Nevertheless, given the large volumes of effluent constantly discharged to receivers, even tertiary level WWTPs may constitute a considerable source of microplastics in the surface water.


2020 ◽  
Vol 86 (8) ◽  
Author(s):  
Mykhailo Savin ◽  
Gabriele Bierbaum ◽  
Jens Andre Hammerl ◽  
Céline Heinemann ◽  
Marijo Parcina ◽  
...  

ABSTRACT The wastewater of livestock slaughterhouses is considered a source of antimicrobial-resistant bacteria with clinical relevance and may thus be important for their dissemination into the environment. To get an overview of their occurrence and characteristics, we investigated process water (n = 50) from delivery and unclean areas as well as wastewater (n = 32) from the in-house wastewater treatment plants (WWTPs) of two German poultry slaughterhouses (slaughterhouses S1 and S2). The samples were screened for ESKAPE bacteria (Enterococcus spp., Staphylococcus aureus, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, Enterobacter spp.) and Escherichia coli. Their antimicrobial resistance phenotypes and the presence of extended-spectrum-β-lactamase (ESBL), carbapenemase, and mobilizable colistin resistance genes were determined. Selected ESKAPE bacteria were epidemiologically classified using different molecular typing techniques. At least one of the target species was detected in 87.5% (n = 28/32) of the wastewater samples and 86.0% (n = 43/50) of the process water samples. The vast majority of the recovered isolates (94.9%, n = 448/472) was represented by E. coli (39.4%), the A. calcoaceticus-A. baumannii (ACB) complex (32.4%), S. aureus (12.3%), and K. pneumoniae (10.8%), which were widely distributed in the delivery and unclean areas of the individual slaughterhouses, including their wastewater effluents. Enterobacter spp., Enterococcus spp., and P. aeruginosa were less abundant and made up 5.1% of the isolates. Phenotypic and genotypic analyses revealed that the recovered isolates exhibited diverse resistance phenotypes and β-lactamase genes. In conclusion, wastewater effluents from the investigated poultry slaughterhouses exhibited clinically relevant bacteria (E. coli, methicillin-resistant S. aureus, K. pneumoniae, and species of the ACB and Enterobacter cloacae complexes) that contribute to the dissemination of clinically relevant resistances (i.e., blaCTX-M or blaSHV and mcr-1) in the environment. IMPORTANCE Bacteria from livestock may be opportunistic pathogens and carriers of clinically relevant resistance genes, as many antimicrobials are used in both veterinary and human medicine. They may be released into the environment from wastewater treatment plants (WWTPs), which are influenced by wastewater from slaughterhouses, thereby endangering public health. Moreover, process water that accumulates during the slaughtering of poultry is an important reservoir for livestock-associated multidrug-resistant bacteria and may serve as a vector of transmission to occupationally exposed slaughterhouse employees. Mitigation solutions aimed at the reduction of the bacterial discharge into the production water circuit as well as interventions against their further transmission and dissemination need to be elaborated. Furthermore, the efficacy of in-house WWTPs needs to be questioned. Reliable data on the occurrence and diversity of clinically relevant bacteria within the slaughtering production chain and in the WWTP effluents in Germany will help to assess their impact on public and environmental health.


2021 ◽  
Vol 26 ◽  
Author(s):  
Maria Camila Zapata Zúñiga ◽  
Miguel Angel Parra-Pérez ◽  
Johan Alexander Álvarez-Berrio ◽  
Nidia Isabel Molina-Gómez

This study aimed to evaluate the efficiency of technologies for removing antibiotics, antibiotic-resistant bacteria and their antibiotic resistance genes, and the countries where they have been developed. For this purpose, was conducted a systematic review to identify the tertiary treatments to remove the above-mentioned pollutants. The ScienceDirect and Scopus databases were used as sources of information, taking into account only experimental research from 2006 to 2019 and technologies with removal rates higher than 70% to the information analyses. From the analysis of 9 technologies evaluated, in a set of 47 investigations, photo-Fenton, and electrochemical treatments were found to be the most efficient in the removal of antibiotics; gamma radiation and photocatalysis with TiO2 and UV revealed better results in the removal of resistant microbial agents and their resistance genes, with efficiencies of 99.9%. As one of the largest producers and consumers of antibiotics, China appears to be the country with the most scientific research on the area. The importance of innovation in wastewater treatment processes to achieve better results in the remotion of antibiotics, antibiotic-resistant bacteria, and their resistance genes is highlighted, given the effects on the aquatic ecosystems and public health.


Sign in / Sign up

Export Citation Format

Share Document