scholarly journals Scaling of nanofiltration membranes used for chromium(III) ions recovery from salt solutions

2017 ◽  
Vol 76 (11) ◽  
pp. 3135-3141 ◽  
Author(s):  
A. Kowalik-Klimczak ◽  
P. Gierycz

Abstract The effect of membranes' structure on the efficiency of chromium(III) ions recovery from salt solution at low pH and the efficiency of chemical cleaning of these membranes were analyzed in this work. The nanofiltration membranes (DL and HL) used in this study were provided by GE Osmonics. The DL membrane had an irregular, dense support layer structure, while the HL membrane had a loose one. In the case of the DL membrane, it was found that, under tested solutions, the layer of mineral scale formed on the surface gradually decreases the membrane permeability coefficient. In the case of the DL membrane, the scaling was observed only on the surface. On the other hand, a small roughness (118Å) and low density charge (zeta potential at level −4) of the HL membrane causes an uneven growth in deposits and, consequently, irregular nature of the surface structure which hinders the removal of accumulated sediment from the tested membranes' surface. Additionally, the loose structure of the support layer of HL membrane contributes to its internal scaling. Consequently, the permanently loose structure of the HL membrane permeability coefficient was observed.

2015 ◽  
Vol 72 (10) ◽  
pp. 1803-1809 ◽  
Author(s):  
P. Religa ◽  
A. Kowalik-Klimczak

The effect of the anionic surfactant on the permeation properties of the nanofiltration (NF) membranes used for chromium(III) recovery from saline solution at low pH have been presented in this paper. The membrane surface layer performance periodically modified by sodium dodecyl sulphate (SDS) solution has been studied with measurements of zeta potential, atomic force microscopy (AFM) and permeability coefficient of tested membranes. It was found that the membrane surface layer modification by SDS caused a substantial reduction in the possibility of separation of loose NF membrane characterized by a high density of positively charged groups activating under the effect of the low pH of the saline solutions (HL membrane). On the other hand, in the case of dense NF membranes characterized by a strong negatively charged surface (DL membrane) constituting used the SDS improves the separation of chloride and chromium(III) ions. In this case, the surfactant solution also provides a high membrane permeability coefficient behavior over a long period of use. DL membrane modification by SDS allowed both to retain the stable membrane working for a long period and to limit the frequency of the chemical cleaning of this membrane.


2012 ◽  
pp. 381-384 ◽  
Author(s):  
M.A. Theoleyre ◽  
Anne Gonin ◽  
Dominique Paillat

Regeneration of resins used for decolorization of sugar solutions is done with concentrated salt solutions. Nanofiltration membranes have been proven effective, in terms of industrial efficiency in decreasing salt consumption. More than 90% of the salt that is necessary for regeneration can be recycled through a combination of direct recycling of intermediate eluates, the separation of colored compounds by use of very selective nanofiltration membranes and a multiple-effect evaporation of salty permeates. The desalted color compound solution is sent to the molasses, limiting considerably the effluent to be treated. Starting from a liquor of 800 IU, the water requirement is limited to less than 100 L/t of sugar and the amount of wastewater can be reduced to less than 40 L/t of sugar.


2016 ◽  
pp. 377-380
Author(s):  
Marc André Théoleyre ◽  
Anne Gonin ◽  
Dominique Paillat

Regeneration of resins used for decolorization of sugar solutions is done with concentrated salt solutions. Nanofiltration membranes have been proven effective, in terms of industrial efficiency in decreasing salt consumption. More than 90% of the salt that is necessary for regeneration can be recycled through a combination of direct recycling of intermediate eluates, the separation of colored compounds by use of very selective nanofiltration membranes and a system to concentrate salty permeates. According to specific local conditions on energy supply and cost, the concentration of salty permeates can be either a multiple effect evaporator or a combination of electrodialysis and reverse osmosis. The desalted color compound solution is sent to the molasses, limiting considerably the effluent to be treated. Starting from a liquor of 800 IU, the water requirement is limited to less than 100 L/t of sugar and the amount of wastewater can be reduced to less than 40 L/t of sugar.


1982 ◽  
Vol 47 (10) ◽  
pp. 2716-2723 ◽  
Author(s):  
Lubomíra Rexová-Benková ◽  
Jiřina Omelková ◽  
Vladimír Kubánek

Endo-D-galacturonanase of Aspergillus sp. was irreversibly adsorbed on polyethyleneterephthalate in an acetate 0.1 mol l-1 buffer solution of pH 4.2. Immobilization of the enzyme resulted in lowering of its activity, the measure of which depended on the amount of the enzyme fixed on the carrier. The highest relative activity (42.4%) had the preparation containing 5.25 mg of the enzyme per 1 g of the carrier. The velocity and intensity of the sorption of the enzyme depended on the ionic strength of the medium, whilst pH, on the other hand, was of no influence. Endo-D-galacturonanase immobilized in a 0.1 mol l-1 buffer was characteristic a) of its fixation strength in salt solutions of various ionic strength and pH, in a 3 mol l-1 guanidine solution, and also in sodium pectate and pectin solutions, b) of its high stability during a long-lasting storage at 4 °C, c) of its operational stability. The immobilization led to a partial change of the action pattern onto the high-molecular substrate, manifested in lowering the decrease of viscosity to degradation degree ratio.


Minerals ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 330
Author(s):  
Libo Pan ◽  
Xiao Guan ◽  
Bo Liu ◽  
Yanjun Chen ◽  
Ying Pei ◽  
...  

Acid mine drainage (AMD) from abandoned coal mines can lead to serious environmental problems due to its low pH and high concentrations of potentially toxic elements. In this study, soil pH, sulfur (S) content, and arsenic (As), cadmium (Cd), chromium (Cr), copper (Cu), lead (Pb), nickel (Ni), zinc (Zn), iron (Fe), manganese (Mn), and mercury (Hg) concentrations were measured in 27 surface soil samples from areas in which coal-mining activities ceased nine years previously in Youyu Catchment, Guizhou Province, China. The soil was acidic, with a mean pH of 5.28. Cadmium was the only element with a mean concentration higher than the national soil quality standard. As, Cd, Cu, Ni, Zn, Mn, Cr, and Fe concentrations were all higher than the background values in Guizhou Province. This was especially true for the Cd, Cu, and Fe concentrations, which were 1.69, 1.95, and 12.18 times their respective background values. The geoaccumulation index of Cd and Fe was present at unpolluted to moderately polluted and heavily polluted levels, respectively, indicating higher pollution levels than for the other elements in the study area. Spatially, significantly high Fe and S concentrations, as well as extremely low pH values, were found in the soils of the AMD sites; however, sites where tributaries merged with the Youyu River (TM) had the highest Cd pollution level. Iron originated mainly from non-point sources (e.g., AMD and coal gangues), while AMD and agricultural activity were the predominant sources of Cd. The results of an eco-risk assessment indicated that Cd levels presented a moderate potential ecological risk, while the other elements all posed a low risk. For the TM sites, the highest eco-risk was for Cd, with levels that could be harmful for aquatic organisms in the wet season, and may endanger human health via the food chain.


1986 ◽  
Vol 43 (2) ◽  
pp. 444-456 ◽  
Author(s):  
J. C. H. Carter ◽  
W. D. Taylor ◽  
R. Chengalath ◽  
D. A. Scruton

Crustacean and rotifer plankton assemblages of 93 lakes in Labrador, 107 in Newfoundland, and 142 in New Brunswick – Nova Scotia were investigated for evidence of correlations with lake morphometric, chemical, or biological factors. Labrador assemblages were almost completely lacking in identifiable structure. Newfoundland species clustered into two groups of different body size, suggesting the influence of fish predation. Only one species in Labrador and Newfoundland was significantly correlated with a derived factor related to lake water buffering capacity. New Brunswick – Nova Scotia species clustered into two groups, one featuring significant positive and the other significant negative correlations with the buffering factor. From this we conclude that acidification is having an impact on the limnetic zooplankton of these two provinces. Multiple discriminant analysis was used to demonstrate that New Brunswick – Nova Scotia lakes differing in their buffering capacity were also distinct in zooplankton composition. Lakes with low factor scores (low pH, alkalinity, and calcium) were mainly located in the Bay of Fundy region; this area has above average fog and precipitation, and lies within the summer air flow carrying pollutants from the south.


1965 ◽  
Vol 32 (1) ◽  
pp. 57-63 ◽  
Author(s):  
R. Beeby

SummaryWhen crude к-casein was precipitated at pH 3 in the presence of 0·4m-NaCl the supernatant contained up to 80% of the total sialic acid but no detectable cystine or cysteine. Two fractions were obtained from this supernatant by chromatography on DEAE cellulose; one containing 4–6% sialic acid and the other only onetenth of this amount.Most of the sialic acid of the sialic acid-rich fraction was soluble in 12% trichloracetic acid following treatment with rennin. It is suggested that the glycopeptide released by the action of the enzyme on casein originates from this fraction.


1986 ◽  
Vol 164 (1) ◽  
pp. 72-89 ◽  
Author(s):  
M Capron ◽  
T Jouault ◽  
L Prin ◽  
M Joseph ◽  
J C Ameisen ◽  
...  

An IgM mAb (BB10) was produced by immunization of mice with human eosinophils purified according to their abnormal low density ("hypodense" cells), and previously shown to exhibit increased IgE-dependent antiparasite cytotoxicity. This BB10 antibody, selected for positive fluorescence staining of hypodense blood or lung eosinophils and low or negative staining of normodense eosinophils or neutrophils, could strongly inhibit IgE-dependent cytotoxicity of human eosinophils and platelets. The specificity for the IgE Fc receptor was suggested by the high levels of inhibition of IgE rosettes formed by eosinophils after incubation with the purified IgM fraction of BB10, whereas other receptors (Fc gamma R, CR1) were not affected. On the other hand, BB10, able to inhibit rat eosinophil Fc epsilon R, did not react with the IgE Fc receptor on mast cells or basophils. A technique using radioiodinated BB10 allowed us to quantify the specific binding of BB10 to human eosinophils and platelets. Competition experiments revealed a crossinhibition between the binding of BB10 and IgE, suggesting the specificity of BB10 for the IgE binding site of eosinophil, platelet, and monocyte Fc epsilon R. Three proteins having extrapolated Mr of 32,000, 43,000-45,000, and 97,000 were found in the platelet extract eluted from a BB10 or from an IgE immunosorbent column. These findings confirm the similarities between IgE Fc receptors on human eosinophils, platelets, and macrophages, already observed with polyclonal antibodies directed against the B lymphocyte Fc epsilon receptor. They suggest, moreover, that the mAb BB10 can represent a good reagent for further investigations on the structure and the functions of this IgE Fc receptor (Fc epsilon R2).


1938 ◽  
Vol 21 (4) ◽  
pp. 411-430 ◽  
Author(s):  
Aurin M. Chase ◽  
Charles Haig

The absorption spectra of visual purple solutions extracted by various means were measured with a sensitive photoelectric spectrophotometer and compared with the classical visual purple absorption spectrum. Hardening the retinas in alum before extraction yielded visual purple solutions of much higher light transmission in the blue and violet, probably because of the removal of light-dispersing substances. Re-extraction indicated that visual purple is more soluble in the extractive than are the other colored retinal components. However, the concentration of the extractive did not affect the color purity of the extraction but did influence the keeping power. This suggests a chemical combination between the extractive and visual purple. The pH of the extractive affected the color purity of the resulting solution. Over the pH range from 5.5 to 10.0, the visual purple color purity was greatest at the low pH. Temperature during extraction was also effective, the color purity being greater the higher the temperature, up to 40°C. Drying and subsequent re-dissolving of visual purple solutions extracted with digitalin freed the solution of some protein impurities and increased its keeping power. Dialysis against distilled water seemed to precipitate visual purple from solution irreversibly. None of the treatments described improved the symmetry of the unbleached visual purple absorption spectrum sufficiently for it to resemble the classical absorption spectrum. Therefore it is very likely that the classical absorption spectrum is that of the light-sensitive group only and that the absorption spectra of our purest unbleached visual purple solutions represent the molecule as a whole.


Author(s):  
Юрий Николаевич Рыбаков ◽  
Александр Васильевич Дедов ◽  
Роман Игоревич Кюннап ◽  
Сергей Владимирович Ларионов

Исследована проницаемость фторированного полиэтилена высокого давления (ПВД), предназначенного для изготовления ремонтных и технологических вкладышей резервуаров складов временного хранения топлива. Использование таких вкладышей позволяет снизить технологические потери углеводородов и увеличить надежность хранилищ из полимерных материалов. В качестве объекта исследования использовали пленки ПВД 10204-003 толщиной 100 мкм. Проницаемость пленок определяли при контакте с бензином марок Нормаль-80, Премиум-95, авиационным керосином ТС-1 и дизельным топливом. Рассмотрен механизм формирования структуры поверхностного фторированного слоя. Исследована кинетика изменения коэффициента проницаемости исходного и модифицированного полиэтилена в течение возможного срока хранения топлив. По результатам исследования установлено: 1) в полиэтилене перенос топлива протекает в две стадии, что определяется раздельной диффузией низкомолекулярных и высокомолекулярных фракций углеводородов; 2) фторирование полиэтилена приводит к уменьшению коэффициента проницаемости (что имеет практическое значение для сохранения качества топлива), но не влияет на перенос фракции углеводородов минимальной молекулярной массы. The permeability of fluorinated high-pressure polyethylene (HDPE), intended for the manufacture of repair and technological liners of tanks for temporary fuel storage has been investigated. As the object of research, 10204-003 HDPE films with 100 μm thickness were used. The permeability of the films was determined by contact with gasoline of the Normal-80 and Premium-95 brands, aviation kerosene TS-1, and diesel fuel. The formation mechanism of the surface fluorinated layer structure was considered. The kinetics of changes in the permeability coefficient of the original and modified polyethylene during the possible fuel storage period has been studied. It has been established that the transfer of fuel in polyethylene proceeds in two stages, which is determined by the separate diffusion of low-molecular and high-molecular hydrocarbon fractions. Fluoridation of polyethylene decreases the permeability coefficient, but does not affect the transfer of hydrocarbon fraction with the minimum molecular weight.


Sign in / Sign up

Export Citation Format

Share Document