Cloud point extraction–flame atomic absorption spectrometry method for preconcentration and determination of trace cadmium in water samples

2014 ◽  
Vol 70 (4) ◽  
pp. 605-611 ◽  
Author(s):  
Jinyan Ning ◽  
Yang Jiao ◽  
Jiao Zhao ◽  
Lifen Meng ◽  
Yaling Yang

A method based on cloud point extraction (CPE) separation/preconcentration of trace cadmium (Cd) as a prior step to its determination by flame atomic absorption spectrometry has been developed. Cadmium reacted with 8-hydroxyquinoline to form hydrophobic chelates, which were extracted into the micelles of nonionic surfactant oligoethylene glycol monoalkyl ether (Genapol X-080) in an alkaline medium. Octanol was used to depress the cloud point of Genapol X-080 in the extraction process. The chemical variables that affect the CPE, such as pH of complexation reaction, amount of chelating agent, Genapol X-080 and octanol were evaluated and optimized. Under optimized conditions, linearity was obeyed in the range of 10–500 μg/L, with the correlation coefficient of 0.9993. For 5 mL of sample solution, the enhancement factor was about 20. The limit of detection and limit of quantification of the method were 0.21 and 0.63 μg/L, respectively. The relative standard deviations (n = 6) was 3.2% for a solution containing 100 μg/L of Cd. The accuracy of the preconcentration system was evaluated by recovery measurements on spiked water samples. Recoveries of spiked samples varied in the range of 94.1–103.8%.

2014 ◽  
Vol 70 (12) ◽  
pp. 1913-1918 ◽  
Author(s):  
Lifen Meng ◽  
Jinyan Ning ◽  
Yaling Yang

A sensitive and simple method for flame atomic absorption spectrometry determination of traces of cadmium and chromium(III) species in water samples after preconcentration by cloud point extraction has been developed. A novel complex agent of alizarin complexone with cadmium (Cd) and chromium (Cr(III)) was quantitatively extracted in surface primary alcohol ethoxylate-rich phase at 33 °C. The effects of experimental conditions including pH of sample solution, concentration of chelating agent and salt, equilibration temperature and time, and foreign ions were evaluated in order to enhance sensitivity of the method. Under optimal conditions, the low limit detections were 6.7 and 3.2 μg/L, and the enrichment factors were 24 and 20 for Cd and Cr(III), respectively. The relative standard deviations were 3.8 and 2.5% for Cd and Cr(II), respectively (n = 11). The high recoveries of the spiked Cd and Cr(III) ions were obtained in the range of 90–116%. The proposed method has been successfully applied for the determination of Cd and Cr(III) in water samples.


Sign in / Sign up

Export Citation Format

Share Document