Improved derivatization protocol for simultaneous determination of alkylphenol ethoxylates and brominated flame retardants followed by gas chromatography-mass spectrometry analyses

2014 ◽  
Vol 69 (12) ◽  
pp. 2389-2396 ◽  
Author(s):  
T. B. Chokwe ◽  
J. O. Okonkwo ◽  
L. L. Sibali ◽  
E. J. Ncube

An improved derivatization protocol for the simultaneous determination of alkylphenol ethoxylates and brominated flame retardants with heptafluorobutyric anhydride under triethylamine amine base was investigated. The derivatization reaction was completed in 30 min at 50 °C using hexane as solvent. Under these conditions, it was observed that alkylphenol ethoxylates and tetrabromobisphenol A were derivatized successfully in the presence of hexabromocyclododecane, lower congeners of polybrominated biphenyls and polybrominated diphenyl ethers. The improved protocol was applied to the recover of the analytes of interest from a simulated water sample after solid phase extraction. The recoveries achieved were above 60%. The limit of detection and limit of quantification ranged from 0.01–0.20 and 0.05–0.66 μg L−1, respectively. The improved derivatization procedure was also successfully applied to determine trace amounts of these compounds in environmental water samples. The concentrations of the targeted analytes from the environmental samples were determined from limit of quantification. The levels of the targeted compounds in the environmental samples ranged from nd-7.63 ±2.83 μg L−1.

1989 ◽  
Vol 72 (2) ◽  
pp. 349-354 ◽  
Author(s):  
Lee Q Huang

Abstract A multiresidue method was developed for the simultaneous determination of low parts per billion (ppb) concentrations of the herbicides alachlor, metolachlor, atrazine, and simazine in water and soil using isotope dilution gas chromatography/mass spectrometry (GC/MS). Known amounts of 15N,13C-alachlor and 2H5-atrazine were added to each sample as internal standards. The samples were then prepared by a solid phase extraction with no further cleanup. A high resolution GC/low resolution MS system with data acquisition in selected ion monitoring mode was used to quantitate herbicides in the extract. The limit of detection was 0.05 ppb for water and 0.5 ppb for soil. Accuracy greater than 80% and precision better than 4% was demonstrated with spiked samples.


Molecules ◽  
2021 ◽  
Vol 26 (7) ◽  
pp. 1837
Author(s):  
Harischandra Naik Rathod ◽  
Bheemanna Mallappa ◽  
Pallavi Malenahalli Sidramappa ◽  
Chandra Sekhara Reddy Vennapusa ◽  
Pavankumar Kamin ◽  
...  

A quick, sensitive, and reproducible analytical method for the determination of 77 multiclass pesticides and their metabolites in Capsicum and tomato by gas and liquid chromatography tandem mass spectrometry was standardized and validated. The limit of detection of 0.19 to 10.91 and limit of quantification of 0.63 to 36.34 µg·kg−1 for Capsicum and 0.10 to 9.55 µg·kg−1 (LOD) and 0.35 to 33.43 µg·kg−1 (LOQ) for tomato. The method involves extraction of sample with acetonitrile, purification by dispersive solid phase extraction using primary secondary amine and graphitized carbon black. The recoveries of all pesticides were in the range of 75 to 110% with a relative standard deviation of less than 20%. Similarly, the method precision was evaluated interms of repeatability (RSDr) and reproducibility (RSDwR) by spiking of mixed pesticides standards at 100 µg·kg−1 recorded anRSD of less than 20%. The matrix effect was acceptable and no significant variation was observed in both the matrices except for few pesticides. The estimated measurement uncertainty found acceptable for all the pesticides. This method found suitable for analysis of vegetable samples drawn from market and farm gates.


2013 ◽  
Vol 57 (1) ◽  
pp. 25-32 ◽  
Author(s):  
Anna Gajda ◽  
Andrzej Posyniak ◽  
Andrzej Bober ◽  
Tomasz Błądek ◽  
Jan Żmudzki

Summary A liquid chromatography method with UV detection for determination of oxytetracycline (OTC) in honey has been developed. The samples were extracted with the solution of oxalic acid. The clean-up procedure was performed by solid phase extraction (SPE) using polymeric Strata X and carboxylic acid cartridges. Chromatographic separation was carried out on the Luna C8 analytical column with mobile phase consisting of acetonitrile-0.02 M oxalic acid. The method has been successfully validated according to the requirements of the European Decision 2002/657/EC and this method is used in routine control of oxytetracycline in honey samples. The limit of detection (LOD) and limit of quantification (LOQ) of the presented method were 10 and 12.5 μg/kg, respectively. The developed method has also been verified in quantitative determination of oxytetracycline residues in honey after experimental treatment with this product in bee colonies.


Sign in / Sign up

Export Citation Format

Share Document