Comparison of different conditions, substrates and operation modes by dynamic simulation of a full-scale anaerobic SBR plant

2012 ◽  
Vol 65 (3) ◽  
pp. 558-566 ◽  
Author(s):  
S. G. E. Rönner-Holm ◽  
A. Żak ◽  
N. C. Holm

Simulation studies for a full-scale anaerobic unit of a wastewater treatment plant (WWTP) were performed using the anaerobic digestion model no. 1 (ADM1). The anaerobic full-scale plant consists of one mesophilic and one thermophilic digester, operated in an anaerobic sequential batch reactor (ASBR) mode, and sludge enrichment reactors (SER) for each digester. The digesters are fed with a mixture of vegetable waste and process wastewater from the food factory. Characteristics such as CODtotal, Ntotal and NH4-N concentrations in the influent and effluent of the digester and SERs were measured and used for input fractionation. Parameters such as level, pH, biogas amount and composition in the digester were measured online and used for calibration. For simulation studies, different temperatures and operation modes with varying chemical oxygen demand (COD) input loads corresponding to feedstocks such as fruits, vegetables and grain were analysed and compared. Higher gas production and digestion efficiency in the thermophilic reactor and in shorter cycles were found and confirmed at full scale. Serial operation mode increased the gas production, but pH inhibition occurred earlier. Feeding only biosolids into digester I and the effluent of digester I together with process water into digester II further improved gas production in serial operation mode.

1996 ◽  
Vol 33 (1) ◽  
pp. 89-99 ◽  
Author(s):  
F. Göhle ◽  
A. Finnson ◽  
B. Hultman

Bromma sewage treatment plant in Stockholm is the second largest plant in Stockholm and will in the near future have requirements for nitrogen removal. This means that a higher sludge age must be used in the aeration basin. This may be accomplished by an increase of the sludge concentration up to values until the limiting solids flux is exceeded. Measurement of the sludge blanket level is a possibility for better control of the sedimentation basin. Different measurements were performed to evaluate the main factors influencing the level. Dynamic simulation studies were performed at Bromma sewage treatment plant in Stockholm of the sludge blanket level and the return sludge concentration in a full-scale sedimentation basin. The simulations were performed with the help of a Danish simulation package, EFOR (1992), in which both reactions in the aeration basin (mainly based on the IAWPRC model) and separation processes in the sedimentation basin (both clarification and thickening) can be studied. The thickening model is based on the solids flux theory and the Vesilind formula (1979). Different methods were compared for determination and use of characteristic parameters in the Vesilind formula.


2012 ◽  
Vol 7 (1) ◽  
Author(s):  
S. S. Fatima ◽  
S. Jamal Khan

In this study, the performance of wastewater treatment plant located at sector I-9 Islamabad, Pakistan, was evaluated. This full scale domestic wastewater treatment plant is based on conventional activated sludge process. The parameters which were monitored regularly included total suspended solids (TSS), mixed liquor suspended solids (MLSS), mixed liquor volatile suspended solids (MLVSS), biological oxygen demand (BOD), and chemical oxygen demand (COD). It was found that the biological degradation efficiency of the plant was below the desired levels in terms of COD and BOD. Also the plant operators were not maintaining consistent sludge retention time (SRT). Abrupt discharge of MLSS through the Surplus Activated sludge (SAS) pump was the main reason for the low MLSS in the aeration tank and consequently low treatment performance. In this study the SRT was optimized based on desired MLSS concentration between 3,000–3,500 mg/L and required performance in terms of BOD, COD and TSS. This study revealed that SRT is a very important operational parameter and its knowledge and correct implementation by the plant operators should be mandatory.


2017 ◽  
Vol 77 (1) ◽  
pp. 70-78 ◽  
Author(s):  
Yanjun Mao ◽  
Xie Quan ◽  
Huimin Zhao ◽  
Yaobin Zhang ◽  
Shuo Chen ◽  
...  

Abstract The activated sludge (AS) process is widely applied in dyestuff wastewater treatment plants (WWTPs); however, the nitrogen removal efficiency is relatively low and the effluent does not meet the indirect discharge standards before being discharged into the industrial park's WWTP. Hence it is necessary to upgrade the WWTP with more advanced technologies. Moving bed biofilm processes with suspended carriers in an aerobic tank are promising methods due to enhanced nitrification and denitrification. Herein, a pilot-scale integrated free-floating biofilm and activated sludge (IFFAS) process was employed to investigate the feasibility of enhancing nitrogen removal efficiency at different hydraulic retention times (HRTs). The results showed that the effluent chemical oxygen demand (COD), ammonium nitrate (NH4+-N) and total nitrogen (TN) concentrations of the IFFAS process were significantly lower than those of the AS process, and could meet the indirect discharge standards. PCR-DGGE and FISH results indicated that more nitrifiers and denitrifiers co-existed in the IFFAS system, promoting simultaneous nitrification and denitrification. Based on the pilot results, the IFFAS process was used to upgrade the full-scale AS process, and the effluent COD, NH4+-N and TN of the IFFAS process were 91–291 mg/L, 10.6–28.7 mg/L and 18.9–48.6 mg/L, stably meeting the indirect discharge standards and demonstrating the advantages of IFFAS in dyestuff wastewater treatment.


2003 ◽  
Vol 48 (8) ◽  
pp. 9-18 ◽  
Author(s):  
C. Fux ◽  
K. Lange ◽  
A. Faessler ◽  
P. Huber ◽  
B. Grueniger ◽  
...  

Separate biological elimination of nitrogen from the digester supernatant of a municipal wastewater treatment plant (WWTP) was investigated in pilot and full-scale plants. Denitrification mainly via nitrite was achieved in a sequencing batch reactor (SBR) and a continuous flow reactor (CSTR or SHARON). Suppression of nitrite oxidation in the SBR was feasible at short aerobic/anaerobic intervals allowing for immediate denitrification of the produced nitrite. Nitrate production could also be stopped by exposing the biomass to anaerobic conditions for 11 days. Temporarily high concentrations (up to 80 gNH3-Nm-3) of free ammonia could not be considered as the major reason for inhibiting nitrite oxidation. In a full-scale SBR plant 90% of the nitrogen load was denitrified in a total hydraulic retention time (HRT) of 1.6 days and with a sludge age between 15 and 20 days. Ethanol and methanol were used for denitrification. The specific average substrate consumption was 2.2 gCODdosedg-1Nremoved with an effective biomass yield of 0.2 gCODbiomassg-1CODdosed. No dosing with base was required. In the SHARON process full nitrogen elimination was achieved only with a total HRT greater than 4 days at 29°C. The overall costs were estimated at €1.4 kg-1Nremoved for the SBR and €1.63 kg-1Nremoved in SHARON mode, respectively. The SHARON process is simple in operation (CSTR) but the tank volume has to be significantly greater than in SBR.


1995 ◽  
Vol 32 (12) ◽  
pp. 35-42 ◽  
Author(s):  
G. Yilmaz ◽  
I. Öztürk

The objective of this study is to determine the inert soluble COD of wastewaters from the fermentation industry. In this context, a series of experiments were performed for various effluents from baker's yeast industry including raw process wastewater, anaerobic pre-treatment plant effluents, domestic and washing waters mixture. The inert COD ratio (SISO) for the raw effluents from baker's yeast industry was determined as 0.1. This ratio was in the range of 0.20 to 0.30 for the anaerobically pre-treated effluents. TheSISO ratios for the wastewater simulating the effluent of the existing full-scale aerobic treatment plant have varied from 0.18 to 0.48. Such a large variation has been originated from the operating conditions of the existing full-scale anaerobic treatment plants. The higher volumetric loading rates and shorter sludge retention times correspond the lower SISO ratios for the full-scale anaerobic treatment systems in general.


2019 ◽  
Vol 80 (9) ◽  
pp. 1654-1661
Author(s):  
J. Tauber ◽  
V. Parravicini ◽  
K. Svardal ◽  
J. Krampe

Abstract In this research, sources of methane emissions of an anaerobic digester (AD) system at a municipal wastewater treatment plant (WWTP) with 260,000 population equivalent (PE) capacity were detected by a non-dispersive infrared (NDIR) camera. The located emissions were evaluated qualitatively and were documented with photographs and video films. Subsequently, the emission sources were quantified individually using different methods like the Flux-Chamber method and sampling from the digester's circulation pipe. The dissolved methane in the sludge digester was measured via gas chromatography-mass spectrometry (GC-MS) and 6.8% oversaturation compared to the equilibrium after Henry's law was found. Additionally, the residual gas potential of the digestate was measured using batch tests with 10 days' additional stabilisation time. The PE-specific residual gas production of the full-scale AD was calculated to 12.4 g CH4/(PE · y). An extended chemical oxygen demand (COD) balance including methane emissions for the whole digester system was calculated. Also the measured methane loads were calculated and summed up. The total methane loss of the AD was calculated at 24.6 g CH4/(PE · y), which corresponds to 0.4% of the produced biogas (4,913 g CH4/(PE · y)). PE-specific methane emission factors are presented for each investigated (point) source like the sludge outlet at the digester's head, a leaking manhole sealing and cracks in the concrete structure.


2014 ◽  
Vol 2014 ◽  
pp. 1-12 ◽  
Author(s):  
Jun Li ◽  
Li-Bin Ding ◽  
Ang Cai ◽  
Guo-Xian Huang ◽  
Harald Horn

Aerobic granulation of activated sludge was successfully achieved in a full-scale sequencing batch reactor (SBR) with 50,000 m3 d−1for treating a town’s wastewater. After operation for 337 days, in this full-scale SBR, aerobic granules with an average SVI30of 47.1 mL g−1, diameter of 0.5 mm, and settling velocity of 42 m h−1were obtained. Compared to an anaerobic/oxic plug flow (A/O) reactor and an oxidation ditch (OD) being operated in this wastewater treatment plant, the sludge from full-scale SBR has more compact structure and excellent settling ability. Denaturing gradient gel electrophoresis (DGGE) analysis indicated thatFlavobacteriumsp., uncultured beta proteobacterium, unculturedAquabacteriumsp., and unculturedLeptothrixsp. were just dominant in SBR, whereas uncultured bacteroidetes were only found in A/O and OD. Three kinds of sludge had a high content of protein in extracellular polymeric substances (EPS). X-ray fluorescence (XRF) analysis revealed that metal ions and some inorganics from raw wastewater precipitated in sludge acted as core to enhance granulation. Raw wastewater characteristics had a positive effect on the granule formation, but the SBR mode operating with periodic feast-famine, shorter settling time, and no return sludge pump played a crucial role in aerobic sludge granulation.


2016 ◽  
Vol 74 (7) ◽  
pp. 1736-1743 ◽  
Author(s):  
F. Stenström ◽  
J. la Cour Jansen

Bioaugmentation of nitrifiers from a side-stream treatment is an efficient method for boosting the mainstream process at a wastewater treatment plant (WWTP). Although this technology has been known for several years, the number of full-scale applications for it is limited. For a WWTP approaching its critical nitrogen load capacity, the benefits are doubled if the introduced side-stream treatment for digester supernatant is combined with bioaugmentation. Not only is the nitrogen load to the mainstream process decreased by 10–25%, but the mainstream process is also boosted with nitrifiers, increasing the nitrifying capacity. In this full-scale study, the increment of the nitrification rate is examined in the mainstream process at different temperatures and at different flow rates of returned activated sludge to the side-stream treatment. Our results show that the nitrification rate in the mainstream process was increased by 41% during the coldest period of the study, implying that the examined WWTP could treat considerably higher nitrogen loads if bioaugmentation were permanently installed.


2014 ◽  
Vol 1030-1032 ◽  
pp. 387-390
Author(s):  
Chun Di Gao ◽  
Shi Xin Fan ◽  
Er Long Jiao ◽  
Hao Li ◽  
Wei Xiao Wang

A novel alternating oxic-anoxic operation mode of shortcut nitrification-denitrification was developed in a sequencing batch reactor at ambient temperature. Operational parameters favorable for maintaining the shortcut nitrification-denitrification were investigated and optimized. The experiments showed that alternating oxic-anoxic shortcut nitrification-denitrification system was able to be an independent treatment process in domestic wastewater treatment. And the optimization approach was so efficient that the main pollutant discharge targets achieved Standard A of the first class in "Discharge standard of pollutants for municipal wastewater treatment plant". Moreover, the reliability of the operation strategy in this experimentation was proved, which indicated the excellent nitrogen removal performances.


2014 ◽  
Vol 70 (10) ◽  
pp. 1594-1601 ◽  
Author(s):  
Shijian Ge ◽  
Yunpeng Zhu ◽  
Shuang Qiu ◽  
Xiong Yang ◽  
Bin Ma ◽  
...  

This study evaluated the performance of a full-scale upgrade of an existing wastewater treatment plant (WWTP) with the intermittent cyclic extended aeration system (ICEAS), located in Qingdao, China. The ICEAS system was not able to meet effluent standards; therefore, a series of modifications and control strategies were applied as follows: (1) floating plastic carriers were added to the tank to aid biofilm formation; (2) operation parameters such as mixing and aeration time, feeding rate, and settling time were adjusted and controlled with a real-time control system; (3) a sludge return system and submersible water impellers were added; (4) the aeration system was also improved to circulate carriers and prevent clogging. The modified ICEAS system exhibited efficient organic and nutrient removal, with high removal efficiencies of chemical oxygen demand (89.57 ± 4.10%), NH4+-N (95.46 ± 3.80%), and total phosphorus (91.90 ± 4.36%). Moreover, an annual power reduction of 1.04 × 107 kW·h was realized as a result of these modifications.


Sign in / Sign up

Export Citation Format

Share Document