Electro-coagulation treatment of oily wastewater with sludge analysis

2012 ◽  
Vol 66 (12) ◽  
pp. 2533-2538 ◽  
Author(s):  
Dhorgham Skban Ibrahim ◽  
N. Sakthipriya ◽  
N. Balasubramanian

Experiments were carried out in a batch reactor to treat the oily effluent by electro-coagulation. The influence of operating parameters such as applied current, type of electrode and electrolysis time on electro-coagulation efficiency has been critically examined. The maximum percentage removal of chemical oxygen demand (COD) was 94% under optimum experimental conditions of pH 6.7, current density 6 mA/cm2, electrolysis time 40 min, and using mild steel as anode. The remaining sludge in the reactor was analyzed by energy disperse analysis of X-rays (EDAX) and scanning electron microscope (SEM) analysis. The analysis confirms that the oily pollutant was removed by electroflotation and adsorption of the oily particles of precipitate during the electro-coagulation process. Electro-coagulation can be used as an efficient treatment technique for oily wastewater.

2009 ◽  
Vol 60 (9) ◽  
pp. 2261-2270 ◽  
Author(s):  
M. Kobya ◽  
E. Demirbas ◽  
A. Akyol

Electrocoagulation (EC) method with iron electrode was used to treat the textile wastewater in a batch reactor. Iron electrode material was used as a sacrificial electrode in monopolar parallel mode in this study. The removal efficiencies of the wastewater by EC were affected by initial pH of the solution, current density, conductivity and time of electrolysis. Under the optimal experimental conditions (initial pH 6.9, current density of 10 mA/cm2, conductivity of 3,990 μS/cm, and electrolysis time of 10 min), the treatment of textile wastewater by the EC process led to a removal capacity of 78% of chemical oxygen demand (COD) and 92% of turbidity. The energy and electrode consumptions at the optimum conditions were calculated to be 0.7 kWh/kg COD (1.7 kWh/m3) and 0.2 kgFe/kg COD (0.5 kgFe/m3), respectively. Moreover, the operating cost was calculated as 0.2 €/kg removed COD or 0.5 €/m3 treated wastewater. Zeta potential measurement was used to determine the charge of particle formed during the EC which revealed that Fe(OH)3 might be responsible for the EC process.


2020 ◽  
Vol 30 (1) ◽  
Author(s):  
Hanane Afanga ◽  
Hicham Zazou ◽  
Fatima Ezzahra Titchou ◽  
Youness Rakhila ◽  
Rachid Ait Akbour ◽  
...  

AbstractTextile wastewater containing toxic dyes needs efficient treatment before being released into the environment. Certain dyes are known or presumed to have carcinogenic potential for humans. In this work, hybrid electrochemical processes including electrocoagulation (EC) alone and combined with electro Fenton (EF), anodic oxidation (AO) and peroxi-coagulation (PC) were tested to treat real textile wastewater using a batch reactor. A sequential EC and EF (EC-EF) process was found to be more effective. The experimental results indicated that the effectiveness of the treatment decreases in the following order: EC-EF > EC-AO > EC-PC > EC. EC-EF results showed a decrease in chemical oxygen demand (COD, 97%), total organic carbon (98%), total suspended solids (98%), and the concentration of metal species; showing that the treatment of such wastewater type can be achieved by combined EC-EF process in a one-pot bench-scale reactor. The electrical energy consumption, the iron dissolution, and the biological oxygen demand/COD ratios of EC and EC-EF processes were evaluated. Characterization of the sludge generated during EC treatment at current density of 20 mA cm− 2 was carried out. Precipitation, adsorption, and electrochemical oxidation/reduction of organic dyes and metallic ions occurred during the treatment. This investigation shows the efficiency of combined EC-EF to treat textile wastewater.


Author(s):  
V. Annamalai ◽  
L.E. Murr

Economical recovery of copper metal from leach liquors has been carried out by the simple process of cementing copper onto a suitable substrate metal, such as scrap-iron, since the 16th century. The process has, however, a major drawback of consuming more iron than stoichiometrically needed by the reaction.Therefore, many research groups started looking into the process more closely. Though it is accepted that the structural characteristics of the resultant copper deposit cause changes in reaction rates for various experimental conditions, not many systems have been systematically investigated. This paper examines the deposit structures and the kinetic data, and explains the correlations between them.A simple cementation cell along with rotating discs of pure iron (99.9%) were employed in this study to obtain the kinetic results The resultant copper deposits were studied in a Hitachi Perkin-Elmer HHS-2R scanning electron microscope operated at 25kV in the secondary electron emission mode.


2019 ◽  
Vol 1 (2) ◽  
pp. 1
Author(s):  
Lindawati Lindawati

Sebuah Sequencing Batch Reactor (SBR) digunakan untuk mengevaluasi peranan Biochemical Oxygen Demand (BOD) biosensor dalam proses optimasi proses pengolahan nutrien karbon, nitrogen dan fosfat. Hasil penelitian menunjukkan bahwa BOD biosensor dapat dipergunakan untuk penentuan karbon organik, sehingga reduksi siklus SBR dapat dilakukan dan efisiensi proses meningkat. Pola konsumsi karbon organik ditemukan dengan adanya ‘tanda diam’ pada fase anoksik/ anaerobik, di mana dari tanda ini, fase aerobik dapat segera dimulai. Reduksi durasi siklus SBR dari 8 jam menjadi 4 jam meningkatkan efiesiensi pengolahan C, N dan P yang meningkat pula (hampir dua kali lebih tinggi).


Minerals ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 359
Author(s):  
Liping Zhang ◽  
Shengnian Wu ◽  
Nan Zhang ◽  
Ruihan Yao ◽  
Eryong Wu

Salicylic hydroxamic acid is a novel flotation reagent used in mineral processing. However, it impacts the flotation wastewater leaving behind high chromaticity which limits its reuse and affects discharge for mining enterprises. This study researched ozonation catalyzed by the granular activated carbon (GAC) method to treat the chromaticity of the simulated mineral processing wastewater with salicylic hydroxamic acid. The effects of pH value, ozone (O3) concentration, GAC dosage, and reaction time on chromaticity and chemical oxygen demand (CODCr) removal were discussed. The results of individual ozonation experiments showed that the chromaticity removal ratio reached 79% and the effluent chromaticity exceeded the requirement of reuse and discharge when the optimal experimental conditions were pH value 3, ozone concentration 6 mg/L, and reaction time 40 min. The orthogonal experimental results of catalytic ozonation with GAC on chromaticity removal explained that the chromaticity removal ratio could reach 96.36% and the chromaticity of effluent was only 20 when the optimal level of experimental parameters was pH value 2.87, O3 concentration 6 mg/L, GAC dosage 0.06 g/L, reaction time 60 min respectively. The degradation pathway of salicylic hydroxamic acid by ozonation was also considered based on an analysis with ultraviolet absorption spectrum and high-performance liquid chromatography (HPLC).


Author(s):  
Dana A. Da’ana ◽  
Nabil Zouari ◽  
Mohammad Y. Ashfaq ◽  
Mohammed Abu-Dieyeh ◽  
Majeda Khraisheh ◽  
...  

Abstract Purpose of Review This paper reviews various low-cost treatment techniques such as adsorption, permeable reactive barrier, and biological techniques for the simultaneous removal of chemical and microbial contaminants from groundwater and discusses treatment mechanisms of different treatment techniques. This paper also discusses the challenges of groundwater treatment, how to choose the appropriate treatment technique, and cost analysis of groundwater treatment. Recent Findings Various treatment technologies have been used for the treatment of groundwater: physical, chemical, and biological technologies with different success rates. In the literature, various adsorbents have been successfully synthesized from low-cost and environmentally friendly materials. Adsorption is considered an efficient treatment technique for the removal of both toxic elements and pathogens by utilizing different adsorbents. For example, the nanostructures of MgO with a BET surface area of up to 171 m2/g obtained a very high adsorption capacity of 29,131 mg/g for fluoride ions in water, while the incorporation of iron in activated carbon has improved its adsorption capacity to 51.3 mg/g for arsenic. Moreover, certain adsorbents have shown the capability to remove 99% of the rotavirus and adenovirus from groundwater. Summary Groundwater resources are contaminated with toxic metals and pathogens. Therefore, water treatment technologies should be evaluated for their efficiency to remove such contaminants. Determination of the most cost-effective and efficient treatment technique is not an easy task and requires the understanding of various aspects such as the contaminants present in water, the reuse options considered, and cost analysis of the treatment technique.


2018 ◽  
Vol 2017 (3) ◽  
pp. 661-666
Author(s):  
Xu Zeng ◽  
Jun Liu ◽  
Jianfu Zhao

Abstract Catalytic wet oxidation of high concentration pharmaceutical wastewater with Fe3+ as catalyst was carried out in a batch reactor. Results showed that the degradation of pharmaceutical wastewater was enhanced significantly by Fe3+. The effects of reaction parameters, such as the catalyst dose, reaction temperature, time, and initial oxygen pressure, were discussed. The chemical oxygen demand (COD) removal increased with the increases of catalyst dose, temperature, time and oxygen supply. With the initial COD 34,000–35,000 mg/L, approximately 70% COD removal can be achieved under the conditions of catalyst 1.0 g and oxygen pressure 1.0 MPa at 250 °C after 60 min. The results of kinetic studies showed that two reaction steps existed in this oxidation process, which followed an apparent first-order rate law. This process provides an effective approach for the pretreatment of high concentration pharmaceutical wastewater.


2012 ◽  
Vol 441 ◽  
pp. 555-558
Author(s):  
Feng Tao Chen ◽  
San Chuan Yu ◽  
Xing Qiong Mu ◽  
Shi Shen Zhang

The Ti/SnO2-Sb2O3/PbO2 electrodes were prepared by thermal decomposition method and its application in the electrochemical degradation of a heteropolyaromatic dye, Methylene blue (MB), contained in simulated dye wastewater were investigated under mild conditions. The effects of pH, current density and electrolysis time on de-colorization efficiency were also studied. Chemical oxygen demand (COD) was selected as another parameter to evaluate the efficiency of this degradation method on treatment of MB wastewater. The results revealed that when initial pH was 6.0, current density was 50 mA·cm2, electrolysis time was 60 min, Na2SO4 as electrolyte and its concentration was 3.0 g·dm3, the de-colorization and COD removal efficiency can reach 89.9% and 71.7%, respectively.


2017 ◽  
Vol 77 (4) ◽  
pp. 988-998 ◽  
Author(s):  
Tadesse Alemu ◽  
Andualem Mekonnen ◽  
Seyoum Leta

Abstract In the present study, a pilot scale horizontal subsurface flow constructed wetland (CW) system planted with Phragmites karka; longitudinal profile was studied. The wetland was fed with tannery wastewater, pretreated in a two-stage anaerobic digester followed by a sequence batch reactor. Samples from each CW were taken and analyzed using standard methods. The removal efficiency of the CW system in terms of biological oxygen demand (BOD), chemical oxygen demand (COD), Cr and total coliforms were 91.3%, 90%, 97.3% and 99%, respectively. The removal efficiency for TN, NO3− and NH4+-N were 77.7%, 66.3% and 67.7%, respectively. Similarly, the removal efficiency of SO42−, S2− and total suspended solids (TSS) were 71.8%, 88.7% and 81.2%, respectively. The concentration of COD, BOD, TN, NO3−N, NH4+-N, SO42 and S2− in the final treated effluent were 113.2 ± 52, 56 ± 18, 49.3 ± 13, 22.75 ± 20, 17.1 ± 6.75, 88 ± 120 and 0.4 ± 0.44 mg/L, respectively. Pollutants removal was decreased in the first 12 m and increased along the CW cells. P. karka development in the first cell of CW was poor, small in size and experiencing chlorosis, but clogging was higher in this area due to high organic matter settling, causing a partial surface flow. The performance of the pilot CW as a tertiary treatment showed that the effluent meets the permissible discharge standards.


Author(s):  
Vijay A. Juwar ◽  
Ajit P. Rathod

Abstract The present study deals with the treatment of complex waste (WW) treated for removal of chemical oxygen demand (COD) of the food industry by a sono-Fenton process using a batch reactor. The response surface methodology (RSM) was employed to investigate the five independent variables, such as reaction time, the molar ratio of H2O2/Fe2+, volume ratio of H2O2/WW, pH of waste, and ultrasonic density on COD removal. The experimental data was optimized. The optimization yields the conditions: Reaction time of 24 min, HP:Fe molar ratio of 2.8, HP:WW volume ratio of 1.9 ml/L, pH of 3.6 and an ultrasonic density of 1.8 W/L. The predicted value of COD was 91% and the experimental result was 90%. The composite desirability value (D) of the predicted percent of COD removal at the optimized level of variables was close to one (D = 0.991).


Sign in / Sign up

Export Citation Format

Share Document