Control of odour emission in wastewater treatment plants by direct and undirected measurement of odour emission capacity

2012 ◽  
Vol 66 (8) ◽  
pp. 1627-1633 ◽  
Author(s):  
T. Zarra ◽  
S. Giuliani ◽  
V. Naddeo ◽  
V. Belgiorno

Odour emissions from wastewater treatment plants (WWTPs) are considered to be the main causes of disturbance noticed by the exposed population and have relevant impacts on both tourism economy and land costs. Odour impact from WWTPs is generated by primary and secondary odour emissions. Primary odour emissions are related especially to the wastewater type and variability discharged into the sewer and directed to the WWTP, and to the wastewater collection and sewage system. Secondary odours are related to the treatment units of the plant. Several studies describe the key role of primary odour emissions and how they are strongly related to odour impacts of WWTPs. In this way, a opportune characterization of the emission capacity of primary odour could be an effective way to control odour emission in the WWTPs. In this study the odour emission capacity (OEC) of different domestic sewers was described and investigated; a correlation between the OEC and the main physical–chemical parameters of wastewater quality was also carried out. Results of this study identify the optimum conditions for sampling and measuring OEC in wastewaters and define its dependence by wastewater quality. These results can contribute to setting the standards for the maximum odourant content of wastewater that are discharged into the publicly owned sewage system.

2009 ◽  
Vol 59 (8) ◽  
pp. 1603-1609 ◽  
Author(s):  
T. Zarra ◽  
V. Naddeo ◽  
V. Belgiorno ◽  
M. Reiser ◽  
M. Kranert

Odour emissions are a major environmental issue in wastewater treatment plants and are considered to be the main cause of disturbance noticed by the exposed population. Odour measurement is carried out using analytical or sensorial methods. Sensorial analysis, being assigned to the “human sensor”, is the cause of a considerable uncertainty. In this study a correlation between analytical and sensorial methods was investigated. A novel tool was used to both define odour indexes and characterise the odour sources and the volatile substances that cause annoyance in a wastewater treatment plant, with the aim to remove the subjective component in the measure of the odours and define the induced impact. The sources and the main chemical substances responsible for the olfactory annoyances were identified. Around 36 different substances were detected, with more than half being smell relevant components as well as responsible. Dimethyl disulphide was identified as key compound. Results highlight the applicability of highly correlation between analytical and sensorial methods in odour emission monitoring.


2004 ◽  
Vol 50 (4) ◽  
pp. 139-146 ◽  
Author(s):  
F.-B. Frechen

Wastewater Treatment plants can cause odour emissions that may lead to significant odour annoyance in their vicinity. Thus, over the past 20 years, several measurements were taken of the odour emissions that occur at WWTPs of different sizes, treatment technology, plant design and under different operating conditions. The specific aspects of odour sampling and measurement have to be considered. I presented some of the results of my odour emission measurements 11 years ago. However, it is now necessary to update the figures by evaluating newer measurement results obtained from measurements taken from 1994 to 2003. These are presented in this paper. Also, the paper highlights the odour emission capacity (OEC) measurement technique which characterises liquids and can be used to assess the results achieved by different types of treatment in the liquid phase, e.g. in a sewerage system. In addition, the OEC is a suitable parameter to set standards for the odorant content of industrial wastewaters that are discharged into the publicly owned sewerage system.


2008 ◽  
Vol 58 (1) ◽  
pp. 89-94 ◽  
Author(s):  
T. Zarra ◽  
V. Naddeo ◽  
V. Belgiorno ◽  
M. Reiser ◽  
M. Kranert

Small wastewater treatment plants are often localized nearby tourist areas. Odour emissions are a major environmental issue in these plants and are considered to be the main cause of disturbance noticed by the exposed population. Odour measurement is carried out using analytical or sensorial methods. Sensorial analysis, being assigned to the “human sensor”, is the cause of a considerable uncertainty. In this study, a novel procedure based on highly innovative analytical tool was used to identify and characterise the odour sources and the volatile substances that cause annoyance in a SWWTP located in a sensitive area, with the aim to remove the subjective component in the measure of the odours and define the induced impact. At the same time key odour compounds are detected, and the relationship between their concentration and the performances of the plant are investigated. The sources and the main chemical substances responsible for the olfactory annoyances were identified. Results highlight the applicability of the highly innovative tool in odour emission monitoring. Around 39 different substances were detected, with almost half being smell relevant components as well as responsible. Dimethyl disulphide was identified as key compound connected to the efficiency of the process.


1994 ◽  
Vol 29 (7) ◽  
pp. 229-237 ◽  
Author(s):  
J. Kruit ◽  
F. Boley ◽  
L. J. A. M. Jacobs ◽  
T. W. M. Wouda

Influent characterization and biosorption experiments were carried out with settled influent of seven wastewater treatment plants to study the influence of O2 in the selector in relation to the success of developing good settling properties of the sludge. In previous years working selectors were installed and/or pilot plant research was carried out at these wastewater treatment plants. Characterization of the influent was done with help of standard COD and BOD measurements with help of a coarse filter. The research has elucidated that the presence of O2 in the selector, at initial sludge loadings of 3.5-6.5 kg BOD/kg MLSS.d, is important for producing good settling properties of the sludge when the sum of readily biodegradable COD and rapidly hydrolysable COD is greater than 40%. When the sum of sludge COD and slow hydrolysable COD is greater than 50% an unaerated selector can be used.


2021 ◽  
Vol 97 (4) ◽  
Author(s):  
Rute Ferreira ◽  
Rui Amado ◽  
Jorge Padrão ◽  
Vânia Ferreira ◽  
Nicolina M Dias ◽  
...  

ABSTRACT Bacteriophages (phages) are ubiquitous entities present in every conceivable habitat as a result of their bacterial parasitism. Their prevalence and impact in the ecology of bacterial communities and their ability to control pathogens make their characterization essential, particularly of new phages, improving knowledge and potential application. The isolation and characterization of a new lytic phage against Sphaerotilus natans strain DSM 6575, named vB_SnaP-R1 (SnaR1), is here described. Besides being the first sequenced genome of a Sphaerotilus natans infecting phage, 99% of its 41507 bp genome lacks homology with any other sequenced phage, revealing its uniqueness and previous lack of knowledge. Moreover, SnaR1 is the first Podoviridae phage described infecting this bacterium. Sphaerotilus natans is an important filamentous bacterium due to its deleterious effect on wastewater treatment plants (WWTP) and thus, phages may play a role as novel biotechnological tools against filamentous overgrowth in WWTP. The lytic spectrum of SnaR1 was restricted to its host strain, infecting only one out of three S. natans strains and infection assays revealed its ability to reduce bacterial loads. Results suggest SnaR1 as the prototype of a new phage genus and demonstrates its potential as a non-chemical alternative to reduce S. natans DSM 6575 cells.


2021 ◽  
Vol 3 (7) ◽  
Author(s):  
T. S. C. Quintão ◽  
F. G. Silva ◽  
A. L. Pereira ◽  
W. N. Araújo ◽  
P. M. Oliveira ◽  
...  

AbstractHuman enteric viruses, such as enteric adenoviruses (HAdV), are known to be involved with gastrointestinal disorders, especially acute gastroenteritis. Several studies have used HAdV as an indicator of water quality, since they are considered highly stable and widely distributed viruses in water matrices. The aim of this study was to detect and genotype HAdVs in water matrices impacted by discharges of treated effluents from wastewater treatment plants (WWTPs). Wastewater treatment plants from the sanitary system of the Brazilian Federal District were assessed in 2018 and 2019. Samples were collected upstream and downstream from discharge points for each WWTP. Viral concentration based on adsorption-elution and conventional PCR was used for molecular detection, and positive samples were sequenced for phylogenetic analysis. Pluviosity data for the period in which the samples were collected were obtained. Our results demonstrated the presence of HAdVs in 27.2% (61/224) of the samples. The positivity was significantly higher in downstream samples compared to upstream. Moreover, the HAdV positivity was higher in downstream samples collected from receiving water bodies impacted by secondary-level WWTPs in comparison with those impacted by tertiary-level WWTPs. Phylogenetic analysis demonstrated the presence of genotypes 40 and 41, with prevalence of HAdV genotype 41. Despite the predominance of HAdV-41, an increasing frequency of the HAdV-40 was associated with higher pluviosity. In conclusion, this study is the first documentation in the Brazilian Federal District dealing with the prevalence and diversity of HAdVs in several WWTP, along with their correlation with rainfall index.


1992 ◽  
Vol 25 (6) ◽  
pp. 125-139 ◽  
Author(s):  
J. Kappeler ◽  
W. Gujer

To predict the behaviour of biological wastewater treatment plants, the Activated Sludge Model No. 1 is often used. For the application of this model kinetic parameters and wastewater composition must be known. A simple method to estimate kinetic parameters of heterotrophic biomass and COD wastewater fractions is presented. With three different types of batch-tests these parameters and fractions can be determined by measuring oxygen respiration. Our measurements showed that the maximum specific growth rate µmax of heterotrophic biomass depends on temperature, reactor configuration and SRT. In typical wastewater treatment plants of Switzerland the amount of readily biodegradable substrate was generally small (about 9 % of the COD in primary effluent). The same method can also be used to determine kinetic parameters of nitrifying biomass.


2012 ◽  
Vol 65 (9) ◽  
pp. 1676-1683 ◽  
Author(s):  
G. M. Tardy ◽  
V. Bakos ◽  
A. Jobbágy

A survey has been carried out involving 55 Hungarian wastewater treatment plants in order to evaluate the wastewater quality, the applied technologies and the resultant problems. Characteristically the treatment temperature is very wide-ranging from less than 10 °C to higher than 26 °C. Influent quality proved to be very variable regarding both the organic matter (typical COD concentration range 600–1,200 mg l−1) and the nitrogen content (typical NH4-N concentration range 40–80 mg l−1). As a consequence, significant differences have been found in the carbon availability for denitrification from site to site. Forty two percent of the influents proved to lack an appropriate carbon source. As a consequence of carbon deficiency as well as technologies designed and/or operated with non-efficient denitrification, rising sludge in the secondary clarifiers typically occurs especially in summer. In case studies, application of intermittent aeration, low DO reactors, biofilters and anammox processes have been evaluated, as different biological nitrogen removal technologies. With low carbon source availability, favoring denitrification over enhanced biological phosphorus removal has led to an improved nitrogen removal.


2003 ◽  
Vol 33 (3) ◽  
pp. 529-542
Author(s):  
Olfat El-Sebaie ◽  
Ahmed Hussein ◽  
Mohamed Ramadan ◽  
Magda Abd El-Atty ◽  
Helaly Helaly

1998 ◽  
Vol 38 (1) ◽  
pp. 303-310 ◽  
Author(s):  
V. Naidoo ◽  
V. Urbain ◽  
C. A. Buckley

Denitrification kinetics and wastewater characterization of eight different plants in Europe are discussed. Denitrification batch tests revealed three distinct rates except in the cases of Plaisir, Rostock and Orense where 4 rates were observed. The latter three plants revealed atypical rapid initial rates which were between 7 and 21 mgN/gVSS.h. All denitrification kinetics under non-limiting carbon conditions revealed fast first rates which ranged between 3.0 and 7.3 mgN/gVSS.h. Acetate was used to simulate denitrification kinetics with readily biodegradable COD present. Two subsequent rates were observed. Rates 2 and 3 ranged between 2 and 3 mgN/gVSS.h, and 1 and 2 mgN/gVSS.h, respectively. The RBCOD fraction varied between 10 and 19%, except for one of the plants where the value determined was 7%.


Sign in / Sign up

Export Citation Format

Share Document