Distillery wastes as external carbon sources for denitrification in municipal wastewater treatment plants

2012 ◽  
Vol 65 (9) ◽  
pp. 1583-1590 ◽  
Author(s):  
K. Czerwionka ◽  
J. Makinia ◽  
M. Kaszubowska ◽  
J. Majtacz ◽  
M. Angowski

In this study, by-products from alcohol production were examined in terms of their potential application as external carbon sources for enhancing denitrification in biological nutrient removal systems. Three types of batch tests were used to compare the effects of the distillery by-products, such as fusel oil, syrup and reject water, on the non-acclimated activated sludge. Much higher nitrate utilization rates (NURs) were observed for the latter two carbon sources. In the conventional NUR measurements (one-phase experiments), the observed NURs with syrup and reject water were 3.2–3.3 g N/(kg VSS h) compared with 1.0 g N/(kg VSS h) obtained for fusel oils from two different distilleries. When the carbon sources were added at the beginning of the anoxic phase preceded by an anaerobic phase (two-phase experiments), the NURs were 4.2 g N/(kg VSS h) (syrup and reject water) and 2.4–2.7 g N/(kg VSS h) (fusel oils). The heterotrophic yield coefficient, determined based on the conventional OUR measurements, varied in a relatively narrow range (0.72–0.79 g COD/g COD) for all the examined carbon sources. Due to advantageous composition (much higher COD concentrations and COD/N ratios), fusel is a preferred carbon source for practical handling in full-scale wastewater treatment plants.

1994 ◽  
Vol 30 (4) ◽  
pp. 211-214 ◽  
Author(s):  
E. Brands ◽  
M. Liebeskind ◽  
M. Dohmann

This study shows a comparison of important parameters for dynamic simulation concerning the highrate and low-rate activated sludge tanks of several municipal wastewater treatment plants. The parameters for the dynamic simulation of the single-stage process are quite well known, but parameters for the high-ratellow-rate activated sludge process are still missi ng, although a considerable number of wastewater treatment plants are designed and operated that way. At present any attempt to simulate their operation is restricted to the second stage due to missing data concerning growth rate, decay rate, yield coefficient and others.


2004 ◽  
Vol 49 (5-6) ◽  
pp. 39-46 ◽  
Author(s):  
K.-I. Gil ◽  
E. Choi

The recycle water from sludge processing in municipal wastewater treatment plants causes many serious problems in the efficiency and stability of the mainstream process. Thus, the design approach for recycle water is an important part of any biological nutrient removal system design when a retrofit technology is required for upgrading an existing plant. Moreover, the application of nitrogen removal from recycle water using the nitritation process has recently increased due to economic reasons associated with an effective carbon allocation as well as the minimization of aeration costs. However, for the actual application of recycle water nitritation, it has not been fully examined whether or not additional volume would be required in an existing plant. In this paper, the addition of recycle water nitritation to an existing plant was evaluated based on a volume analysis and estimation of final effluent quality. It was expected that using the reserve volume of the aeration tank in existing plants, recycle water nitritation could be applied to a plant without any enlargement. With the addition of recycle water nitritation, it was estimated that the final effluent quality would be improved and stabilized, especially in the winter season.


2019 ◽  
Vol 86 (4) ◽  
Author(s):  
Yang Song ◽  
Cheng-Ying Jiang ◽  
Zong-Lin Liang ◽  
Bao-Jun Wang ◽  
Yong Jiang ◽  
...  

ABSTRACT Microorganisms in wastewater treatment plants (WWTPs) play a key role in the removal of pollutants from municipal and industrial wastewaters. A recent study estimated that activated sludge from global municipal WWTPs harbors 1 × 109 to 2 × 109 microbial species, the majority of which have not yet been cultivated, and 28 core taxa were identified as “most-wanted” ones (L. Wu, D. Ning, B. Zhang, Y. Li, et al., Nat Microbiol 4:1183–1195, 2019, https://doi.org/10.1038/s41564-019-0426-5). Cultivation and characterization of the “most-wanted” core bacteria are critical to understand their genetic, physiological, phylogenetic, and ecological traits, as well as to improve the performance of WWTPs. In this study, we isolated a bacterial strain, designated SJ-1, that represents a novel cluster within Betaproteobacteria and corresponds to OTU_16 within the 28 core taxa in the “most-wanted” list. Strain SJ-1 was identified and nominated as Casimicrobium huifangae gen. nov., sp. nov., of a novel family, Casimicrobiaceae. C. huifangae is ubiquitously distributed and is metabolically versatile. In addition to mineralizing various carbon sources (including carbohydrates, aromatic compounds, and short-chain fatty acids), C. huifangae is capable of nitrate reduction and phosphorus accumulation. The population of C. huifangae accounted for more than 1% of the bacterial population of the activated sludge microbiome from the Qinghe WWTP, which showed seasonal dynamic changes. Cooccurrence analysis suggested that C. huifangae was an important module hub in the bacterial network of Qinghe WWTP. IMPORTANCE The activated sludge process is the most widely applied biotechnology and is one of the best ecosystems to address microbial ecological principles. Yet, the cultivation of core bacteria and the exploration of their physiology and ecology are limited. In this study, the core and novel bacterial taxon C. huifangae was cultivated and characterized. This study revealed that C. huifangae functioned as an important module hub in the activated sludge microbiome, and it potentially plays an important role in municipal wastewater treatment plants.


1996 ◽  
Vol 33 (12) ◽  
pp. 117-126 ◽  
Author(s):  
I. Purtschert ◽  
H. Siegrist ◽  
W. Gujer

In coordination with the EU-guidelines the large wastewater treatment plants in Switzerland have to be extended with enhanced nitrogen removal. Due to the existing plant configuration, the low COD/N ratio and dilute wastewater, denitrification supported by an external carbon source instead of extending the plant may be an interesting and cost effective solution for municipal wastewater treatment. At the wastewater treatment plant Zürich-Werdhölzli different experiments were performed with methanol addition to predenitrification from March to July 1994. The aim of this work was to evaluate the use of methanol as an alternative to plant extension to achieve a higher nitrogen removal efficiency. Therefore, two parallel denitrifying lanes were investigated, one served for methanol addition experiments and the other as a control. The effect of oxygen input into the anoxic zone due to influent, return sludge and mixing was investigated, too. The results show that nitrogen removal efficiency can be substantially increased as compared to the reference lane. The adaptation period for methanol degradation was only a few days and the process was relatively stable. Based on total nitrogen in the inflow, the average denitrification was 55% with methanol addition and 35% without methanol. The yield coefficient YCOD was 0.4 g CODX g−1 CODMe. Due to the small net growth rate of the methanol degraders the denitrification capacity is relatively low and nitrate peak loads cannot be fully denitrified. Hence, methanol as a carbon source requires more or less constant dosing. To prevent nitrate limitation, methanol addition should be controlled by the anoxic nitrate concentrations.


2011 ◽  
Vol 6 (1) ◽  
Author(s):  
A. Iborra-Clar ◽  
J.A. Mendoza-Roca ◽  
A. Bes-Pií ◽  
J.J. Morenilla-Martínez ◽  
I. Bernácer-Bonora ◽  
...  

Rainfall diminution in the last years has entailed water scarcity in plenty of European regions, especially in Mediterranean areas. As a consequence, regional water authorities have enhanced wastewater reclamation and reuse. Thus, the implementation of tertiary treatments has become of paramount importance in the municipal wastewater treatment plants (WWTP) of Valencian Region (Spain). Conventional tertiary treatments consist of a physico-chemical treatment of the secondary effluent followed by sand filtration and UV radiation. However, the addition of coagulants and flocculants sometimes does not contribute significantly in the final water quality. In this work, results of 20-months operation of three WWTP in Valencian Region with different tertiary treatments (two without chemicals addition and another with chemicals addition) are discussed. Besides, experiments with a 2 m3/h pilot plant located in the WWTP Quart-Benager in Valencia were performed in order to evaluate with the same secondary effluent the effect of the chemicals addition on the final water quality. Results showed that the addition of chemicals did not improve the final water quality significantly. These results were observed both comparing the three full scale plants and in the pilot plant operation.


Sign in / Sign up

Export Citation Format

Share Document