Removal of Ni(II) from aqueous solution using Moringa oleifera seeds as a bioadsorbent

2012 ◽  
Vol 65 (8) ◽  
pp. 1435-1440 ◽  
Author(s):  
Thiago L. Marques ◽  
Vanessa N. Alves ◽  
Luciana M. Coelho ◽  
Nívia M. M. Coelho

Metal contaminants are generally removed from effluents by chemical and physical processes which are often associated with disadvantages such as the use of toxic reagents, generation of toxic waste and high costs. Hence, new techniques have been developed, among them the study of natural adsorbents, for instance, the use of Moringa oleifera seeds. The potential of M. oleifera seeds for nickel removal in aqueous systems was investigated. The seeds utilized were obtained from plants grown in Uberlândia/Brazil. After being dried and pulverized, the seeds were treated with 0.1 mol/L NaOH. Fourier transform infrared spectroscopy, scanning electron microscopy and thermogravimetric analyses were used for the characterization of the material. Using the optimized methodology (50 mL of 4.0 mg/L Ni(II), pH range of 4.0–6.0, agitation time of 5 min and adsorption mass of 2.0 g) more than 90% of Ni(II) could be removed from water samples. The sorption data were fitted satisfactorily by the Langmuir adsorption model. Evaluation applying the Langmuir equation gave the monolayer sorption capacity as 29.6 mg/g. The results indicate that this material could be employed in the extraction of nickel, considering its ease of use, low cost and environmental viability, which make it highly attractive for application in developing countries.

2020 ◽  
Author(s):  
Lyle Jones

The electrical Testing and Characterization of the devices built under research conditions on silicon wafers, diced wafers, or package parts have hampered research since the beginning of integrated circuits. The challenges of performing electrical characterization on devices are to acquire useful and accurate data, the ease of use of the test platform, the portability of the test equipment, the ability to automate quickly, to allow modifications to the platform, the ability to change the configuration of the Device Under Test (DUT) or the Memristor Based Design (MBD), and to do this within budget. The devices that this research is focused on are memristors with unique test challenges. Some of the tests performed on memristors are Voltage sweeps, pulsing of Voltages, and threshold Voltages. Standard methods of testing memristors usually require hands-on experience, multiple bulky work stations, and hours of training. This work reports a novel, low-cost, portable test and characterization platform for many types of memristors with a voltage range from -10V to +10V, which is portable, low-cost, built with off-the-shelf components, and with configurability through software and hardware. To demonstrate the performance of the platform, the platform was able to take a virgin memristor from “forming” to operation voltages, and then incrementally change resistances by Voltage Pulsing. The platform within this work allows the researcher flexibility in electrical characterization by being able to accept many memristor types and MBDs, and applying environmental conditions to the MBD, with this flexibility of the platform the productivity of the researcher will increase.


Author(s):  
Monica Carfagni ◽  
Rocco Furferi ◽  
Lapo Governi ◽  
Chiara Santarelli ◽  
Michaela Servi ◽  
...  

Low-cost RGB-D cameras are increasingly used in several research fields including human-machine interaction, safety, robotics, biomedical engineering and even Reverse Engineering applications. Among the plethora of commercial devices, the Intel RealSense cameras proved to be among the best suitable devices, providing a good compromise between cost, ease of use, compactness and precision. Released on the market in January 2018, the new Intel model RealSense D415 has a wide acquisition range (i.e. ~160-10000 mm) and a narrow field of view to capture objects in rapid motion. Given the unexplored potential of this new device, especially when used as a 3D scanner, the present work aims to characterize and to provide metrological considerations on the RealSense D415. In particular, tests are carried out to assess the device performances in the near range (i.e. 100-1000 mm). Characterization is performed by integrating the guidelines of the existing standard (i.e. the German VDI/VDE 2634 part 2 normative) with a number of literature-based strategies. Performance analysis is finally compared against latest close-range sensors, thus providing a useful guidance for researchers and practitioners aiming to use RGB-D cameras in Reverse Engineering applications.


Sensors ◽  
2019 ◽  
Vol 19 (3) ◽  
pp. 489 ◽  
Author(s):  
Monica Carfagni ◽  
Rocco Furferi ◽  
Lapo Governi ◽  
Chiara Santarelli ◽  
Michaela Servi ◽  
...  

Low-cost RGB-D cameras are increasingly being used in several research fields, including human–machine interaction, safety, robotics, biomedical engineering and even reverse engineering applications. Among the plethora of commercial devices, the Intel RealSense cameras have proven to be among the most suitable devices, providing a good compromise between cost, ease of use, compactness and precision. Released on the market in January 2018, the new Intel model RealSense D415 has a wide acquisition range (i.e., ~160–10,000 mm) and a narrow field of view to capture objects in rapid motion. Given the unexplored potential of this new device, especially when used as a 3D scanner, the present work aims to characterize and to provide metrological considerations for the RealSense D415. In particular, tests are carried out to assess the device performance in the near range (i.e., 100–1000 mm). Characterization is performed by integrating the guidelines of the existing standard (i.e., the German VDI/VDE 2634 Part 2) with a number of literature-based strategies. Performance analysis is finally compared against the latest close-range sensors, thus providing a useful guidance for researchers and practitioners aiming to use RGB-D cameras in reverse engineering applications.


2018 ◽  
Vol 9 (1) ◽  
pp. 83-93 ◽  
Author(s):  
Olushola S. Ayanda ◽  
Olusola S. Amodu ◽  
Habibat Adubiaro ◽  
Godwin O. Olutona ◽  
Oluwapese T. Ebenezer ◽  
...  

Abstract The adsorption of alizarin red (AR) dye onto termite hill sample (THs) was investigated. Prior to the adsorption studies, the elemental, morphological, surface and structural properties of THs were examined by modern analytical methods. Instrumental analysis showed that the homogenous micro-structured THs are comprised of iron oxide, silica oxide, and alumina as major components. Experiments showed that the adsorption capacity of AR decreases with increasing pH and initial AR concentrations, and increases with increasing contact time, stirring speed and temperature. The equilibrium study obeyed the Langmuir adsorption model and the kinetics followed the pseudo-second-order model. About 95.0% AR reduction (1.425 mg/g) was achieved when 0.8 g of THs was mixed with 30 mL of 40 mg/L AR solution for 120 min at 400 rpm and a pH of 2. Thermodynamic study suggested that AR adsorption onto THs is spontaneous at higher temperatures of 323 K and above (ΔGo values are negative). However, ΔGo are positive at lower temperatures of 293–313 K, which implies that the adsorption process is not spontaneous at these temperatures. This study showed that THs could be used as alternative, low-cost, natural adsorbents for the removal of dyes from wastewater.


2006 ◽  
Vol 5 (1) ◽  
Author(s):  
Enrique J Berjano

Abstract Radiofrequency ablation is an interventional technique that in recent years has come to be employed in very different medical fields, such as the elimination of cardiac arrhythmias or the destruction of tumors in different locations. In order to investigate and develop new techniques, and also to improve those currently employed, theoretical models and computer simulations are a powerful tool since they provide vital information on the electrical and thermal behavior of ablation rapidly and at low cost. In the future they could even help to plan individual treatment for each patient. This review analyzes the state-of-the-art in theoretical modeling as applied to the study of radiofrequency ablation techniques. Firstly, it describes the most important issues involved in this methodology, including the experimental validation. Secondly, it points out the present limitations, especially those related to the lack of an accurate characterization of the biological tissues. After analyzing the current and future benefits of this technique it finally suggests future lines and trends in the research of this area.


Author(s):  
M.A. Parker ◽  
K.E. Johnson ◽  
C. Hwang ◽  
A. Bermea

We have reported the dependence of the magnetic and recording properties of CoPtCr recording media on the thickness of the Cr underlayer. It was inferred from XRD data that grain-to-grain epitaxy of the Cr with the CoPtCr was responsible for the interaction observed between these layers. However, no cross-sectional TEM (XTEM) work was performed to confirm this inference. In this paper, we report the application of new techniques for preparing XTEM specimens from actual magnetic recording disks, and for layer-by-layer micro-diffraction with an electron probe elongated parallel to the surface of the deposited structure which elucidate the effect of the crystallographic structure of the Cr on that of the CoPtCr.XTEM specimens were prepared from magnetic recording disks by modifying a technique used to prepare semiconductor specimens. After 3mm disks were prepared per the standard XTEM procedure, these disks were then lapped using a tripod polishing device. A grid with a single 1mmx2mm hole was then glued with M-bond 610 to the polished side of the disk.


1974 ◽  
Vol 31 (01) ◽  
pp. 072-085 ◽  
Author(s):  
M Kopitar ◽  
M Stegnar ◽  
B Accetto ◽  
D Lebez

SummaryPlasminogen activator was isolated from disrupted pig leucocytes by the aid of DEAE chromatography, gel filtration on Sephadex G-100 and final purification on CM cellulose, or by preparative gel electrophoresis.Isolated plasminogen activator corresponds No. 3 band of the starting sample of leucocyte cells (that is composed from 10 gel electrophoretic bands).pH optimum was found to be in pH range 8.0–8.5 and the highest pH stability is between pH range 5.0–8.0.Inhibition studies of isolated plasminogen activator were performed with EACA, AMCHA, PAMBA and Trasylol, using Anson and Astrup method. By Astrup method 100% inhibition was found with EACA and Trasylol and 30% with AMCHA. PAMBA gave 60% inhibition already at concentration 10–3 M/ml. Molecular weight of plasminogen activator was determined by gel filtration on Sephadex G-100. The value obtained from 4 different samples was found to be 28000–30500.


Author(s):  
Dirk Doyle ◽  
Lawrence Benedict ◽  
Fritz Christian Awitan

Abstract Novel techniques to expose substrate-level defects are presented in this paper. New techniques such as inter-layer dielectric (ILD) thinning, high keV imaging, and XeF2 poly etch overflow are introduced. We describe these techniques as applied to two different defects types at FEOL. In the first case, by using ILD thinning and high keV imaging, coupled with focused ion beam (FIB) cross section and scanning transmission electron microscopy (STEM,) we were able to judge where to sample for TEM from a top down perspective while simultaneously providing the top down images giving both perspectives on the same sample. In the second case we show retention of the poly Si short after removal of CoSi2 formation on poly. Removal of the CoSi2 exposes the poly Si such that we can utilize XeF2 to remove poly without damaging gate oxide to reveal pinhole defects in the gate oxide. Overall, using these techniques have led to 1) increased chances of successfully finding the defects, 2) better characterization of the defects by having a planar view perspective and 3) reduced time in localizing defects compared to performing cross section alone.


Electronics ◽  
2021 ◽  
Vol 10 (2) ◽  
pp. 140
Author(s):  
Lichen Liu ◽  
Ziping Cao ◽  
Min Chen ◽  
Jun Jiang

This paper reports the fabrication and characterization of (Bi0.48Sb1.52)Te3 thick films using a tape casting process on glass substrates. A slurry of thermoelectric (Bi0.48Sb1.52)Te3 was developed and cured thick films were annealed in a vacuum chamber at 500–600 °C. The microstructure of these films was analyzed, and the Seebeck coefficient and electric conductivity were tested. It was found that the subsequent annealing process must be carefully designed to achieve good thermoelectric properties of these samples. Conductive films were obtained after annealing and led to acceptable thermoelectric performance. While the properties of these initial materials are not at the level of bulk materials, this work demonstrates that the low-cost tape casting technology is promising for fabricating thermoelectric modules for energy conversion.


Sign in / Sign up

Export Citation Format

Share Document