scholarly journals Energy and phosphorus recovery from black water

2011 ◽  
Vol 63 (11) ◽  
pp. 2759-2765 ◽  
Author(s):  
M. S. de Graaff ◽  
H. Temmink ◽  
G. Zeeman ◽  
C. J. N. Buisman

Source-separated black water (BW) (toilet water) containing 38% of the organic material and 68% of the phosphorus in the total household waste (water) stream including kitchen waste, is a potential source for energy and phosphorus recovery. The energy recovered, in the form of electricity and heat, is more than sufficient for anaerobic treatment, nitrogen removal and phosphorus recovery. The phosphorus balance of an upflow anaerobic sludge blanket reactor treating concentrated BW showed a phosphorus conservation of 61% in the anaerobic effluent. Precipitation of phosphate as struvite from this stream resulted in a recovery of 0.22 kgP/p/y, representing 10% of the artificial phosphorus fertiliser production in the world. The remaining part of the phosphorus ended up in the anaerobic sludge, mainly due to precipitation (39%). Low dilution and a high pH favour the accumulation of phosphorus in the anaerobic sludge and this sludge could be used as a phosphorus-enriched organic fertiliser, provided that it is safe regarding heavy metals, pathogens and micro-pollutants.

1999 ◽  
Vol 40 (1) ◽  
pp. 77-84 ◽  
Author(s):  
H. H. P. Fang ◽  
D. Wai-Chung Chung

Experiments were conducted in two 2.8 liter UASB (upflow anaerobic sludge blanket) reactors treating proteinaceous wastewaters at 37° and 55°C with 9 hours of hydraulic retention. Results showed that the mesophilic reactor consistently removed 83.5-85.1% of COD (chemical oxygen demand) at loading rates ranging 8-22 g COD l−1 d−1 (corresponding to 3000-8250 mg l−1 of proteinaceous COD in wastewater), whereas the thermophilic reactor removed only 68.5-82.7%. At 32 g COD l−1 d−1 (i.e. 12000 mg COD l−1), the removal efficiencies were lowered to 75.7% in the mesophilic reactor and 65.1% in the thermophilic reactor. At 42 g COD l−1 d−1, severe sludge washout occurred in the mesophilic reactor; at the same loading rate, the thermophilic reactor removed only 53.8% of COD even though sludge washout was under control. The degradation rate in the both reactors was limited by the initial hydrolysis of proteins. However, batch tests showed that thermophilic sludge had slightly higher methanogenic activities than mesophilic sludge in treating proteins and intermediate acids, except propionate. The sludge yields in mesophilic and thermophilic reactors were 0.066 and 0.099 g VSS g COD−1, respectively. Observations by scanning electron microscopy indicated that both types of sludge granules were of irregular shape. There was little noticeable difference between the two granules; both had neither a layered microstructure nor a predominant bacterial species.


2006 ◽  
Vol 27 (9) ◽  
pp. 1031-1036 ◽  
Author(s):  
H. Makni ◽  
F. Bettaieb ◽  
H. Dhaouadi ◽  
F. M'Henni ◽  
A. Bakhrouf

2010 ◽  
Vol 37 (5) ◽  
pp. 805-813 ◽  
Author(s):  
Siriuma Jawjit ◽  
Winai Liengcharernsit

This study aims to investigate treatment performance of the two-stage upflow anaerobic sludge blanket (UASB) applied to concentrated latex processing wastewater in Thailand. First, optimal conditions including the hydraulic retention time (HRT) in the acid tank and the UASB tank, pH, and temperature (mesophilic and thermophilic) were determined. It was found that the HRT at 24 h and 48 h were the optimal HRT for the acid tank and the UASB tank, respectively. The pH of the system should be controlled at 7 to prevent rubber coagulation and to achieve high treatment performance, and the mesophilic condition (35°C) was found to be the optimal temperature. Second, the two-stage UASB was applied with the optimal conditions mentioned earlier with real wastewater at a latex mill. It was found that methane production was about 0.116 L CH4/g COD removed (16.3–22.8 m3CH4/d), and average chemical oxygen demand (COD) and suspended solids (SS) removal efficiency were about 82% and 92%, respectively. In case of SS removal, the results revealed that the two-stage UASB was capable of overcoming the limitations of the single-stage UASB in treating concentrated latex effluent. The results indicated that application of the two-stage UASB to concentrated latex processing wastewater is feasible. Nevertheless, combination with other treatment systems (e.g., oxidation pond, aerated lagoon) is necessary to meet Thailand's industrial effluent standards (in the case of COD).


1983 ◽  
Vol 15 (8-9) ◽  
pp. 177-195 ◽  
Author(s):  
G Lettinga ◽  
S W Hobma ◽  
L W Hulshoff Pol ◽  
W de Zeeuw ◽  
P de Jong ◽  
...  

This paper aims to contribute to the assesment of a (more) optimal design and operation of a high rate anaerobic waste water treatment process. The discussion will be made on basis of available information of modern anaerobic waste water treatment processes, such as the Anaerobic Filter Process and the Upflow Anaerobic Sludge Blanket process and of recently introduced Attached Film processes.


2011 ◽  
Vol 71-78 ◽  
pp. 2103-2106
Author(s):  
Ming Yue Zheng ◽  
Ming Xia Zheng ◽  
Kai Jun Wang ◽  
Hai Yan

The performance of upflow anaerobic sludge blanket (UASB) fed with three metabolic intermediate (acetate, ethanol, and propionate) respectively was studied. The degradation of metabolic intermediate were investigated to discuss the reason for propionate inhibition problem in anaerobic treatment. The hydraulic retention time (HRT) in the reactors started with 8.0h.The yield rate of biogas were 237ml/gCOD, 242ml/gCOD, 218ml/gCOD for acetate, ethanol and propionate, respectively when finishing start-up under OLR of 5.0 kgCOD/(m3·d) (HRT=9.6h).The HRT remained constant 9.6h,and the substrate concentration was gradually increased from 1,000 to 16,000mg/L as COD,and the organic loading rates(OLR) was from 3.0 to 40.0 kgCOD/(m3·d).The maximum propionate concentration was 41.6 gHPr-COD/L at the organic loading rate of 43.9 kgCOD/(m3·d) (HRT, 9.6h) as well as acetate and ethanol.


2019 ◽  
Vol 80 (8) ◽  
pp. 1505-1511 ◽  
Author(s):  
Nathalie Dyane Miranda Slompo ◽  
Larissa Quartaroli ◽  
Grietje Zeeman ◽  
Gustavo Henrique Ribeiro da Silva ◽  
Luiz Antonio Daniel

Abstract Decentralized sanitary wastewater treatment has become a viable and sustainable alternative, especially for developing countries and small communities. Besides, effluents may present variations in chemical oxygen demand (COD), biochemical oxygen demand (BOD) and total nitrogen values. This study describes the feasibility of using a pilot upflow anaerobic sludge blanket (UASB) reactor to treat wastewater with different organic loads (COD), using black water (BW) and sanitary wastewater, in addition to its potential for preserving nutrients for later recovery and/or reuse. The UASB reactor was operated continuously for 95 weeks, with a hydraulic retention time of 3 days. In Phase 1, the reactor treated simulated BW and achieved 77% CODtotal removal. In Phase 2, treating only sanitary wastewater, the CODtotal removal efficiency was 60%. Phase 3 treated simulated BW again, and CODtotal removal efficiency was somewhat higher than in Phase 1, reaching 81%. In Phase 3, the removal of pathogens was also evaluated: the efficiency was 1.96 log for Escherichia coli and 2.13 log for total coliforms. The UASB reactor was able to withstand large variations in the organic loading rate (0.09–1.49 kg COD m−3 d−1), in continuous operation mode, maintaining a stable organic matter removal.


1999 ◽  
Vol 40 (8) ◽  
pp. 57-62 ◽  
Author(s):  
A. Pun˜al ◽  
J. M. Lema

The start-up and optimisation of a 380 m3 UASB reactor (Up-flow Anaerobic Sludge Blanket) treating wastewater from a fish-canning factory was carried out. At the beginning of the operation the Organic Loading Rate (OLR) was 1 kg COD/m3·d. Then, the load was gradually increased in steps of 50% OLR until the final capacity of the system (4 kg COD/m3·d) was achieved. Wastewater characteristics were highly dependent on the canned product (mussel, tuna, sardines, etc.). In spite of that, a stable operation working at a hydraulic retention time (HRT) of 2 days was maintained. Total Alkalinity (TA) always presented values higher than 3 g CaCO3/l, while the IA/TA ratio (Intermediate Alalinity/Total Alkalinity) was always maintained lower than 0.3. In order to improve granulation conditions, upward velocities from 0.5 to 0.8 m/h were applied. The highest values caused the washout of non-granulated biomass from the reactor, optimum operation being achieved at an upward velocity of 0.7 m/h.


Sign in / Sign up

Export Citation Format

Share Document