scholarly journals Performance of infiltration swales with regard to operation in winter times in an Alpine region

2011 ◽  
Vol 63 (11) ◽  
pp. 2658-2665 ◽  
Author(s):  
Stefan Fach ◽  
Carolina Engelhard ◽  
Nina Wittke ◽  
Wolfgang Rauch

In cold climate regions winter conditions significantly influence the performance of stormwater infiltration devices. Frozen soil and water storage by snow changes their operation. In this paper winter operation of a grassed infiltration swale was investigated using on-site and laboratory measurements. The field investigation of a grassed swale at a parking place in an Alpine region showed that the swale fulfilled its function properly. Although the top layer was frozen for some time, the storage capacity of the swale was sufficient to store the precipitation until the conditions improved. The soil attenuated the air temperature, at 20 cm below ground surface the soil was only frozen for one week. Winter maintenance proved to be a problem, together with the snow from the parking place a lot of gravel and fine particles were deposited at one end of the swale. This decreased the hydraulic conductivity at that point significantly. The laboratory tests with soil columns showed an increase of flow time through the soil column with decreasing soil moisture content. For soil temperatures below 0 °C the hydraulic conductivity was reduced for increasing initial soil moisture contents. All in all the hydraulic conductivity was best around 0 °C for all soil water contents. However, also at minus 5 °C the coefficient of hydraulic conductivity was always at least above 10−6 m/s, thus within the range of tolerated hydraulic conductivity specified in the national guidelines. Nevertheless, the handling of the soil was found to have high influence on the results. The results indicate that in the Alpine region infiltration swales operate sufficiently under winter conditions although with decreased performance.

2019 ◽  
Vol 25 (3) ◽  
pp. 189-202 ◽  
Author(s):  
Ding-Feng Cao ◽  
Bin Shi ◽  
Hong-Hu Zhu ◽  
Chao-Sheng Tang ◽  
Zhan-Pu Song ◽  
...  

ABSTRACT The infiltration and distribution of water through unsaturated soil determine its mechanical and hydrological properties. However, there are few methods that can accurately capture the spatial distribution of moisture inside soil. This study aims to demonstrate the use of actively heated fiber optic (AHFO) and Brillouin optical time domain analysis (BOTDA) technologies for monitoring soil moisture distribution as well as strain distribution. In addition to a laboratory model test, finite element analyses were conducted to interpret the measurements. During the experiment, the fine particle migration was also measured to understand its influence on soil hydraulic conductivity. The results of the experiment indicate that (i) for a soil that has never experienced a watering-dewatering cycle, water infiltration can be accurately calculated using the Richards’ equation; (ii) migration of fine soil particles caused by the watering-dewatering cycle significantly increases the hydraulic conductivity; and (iii) two critical zones (drainage and erosion) play significant roles in determining the overall hydraulic conductivity of the entire soil. This study provides a new method for monitoring the changes in soil moisture, soil strain, and hydraulic conductivity. The observations suggest that the effect of fine particles migration should be considered while evaluating soil moisture distribution and water movement.


2017 ◽  
Vol 34 (4) ◽  
pp. 393
Author(s):  
Zhixiang Chen ◽  
Shunqun Li ◽  
Jinhong Xia ◽  
Kai Wang ◽  
Chao Gui

2019 ◽  
Vol 23 (12) ◽  
pp. 5017-5031 ◽  
Author(s):  
Aaron A. Mohammed ◽  
Igor Pavlovskii ◽  
Edwin E. Cey ◽  
Masaki Hayashi

Abstract. Snowmelt is a major source of groundwater recharge in cold regions. Throughout many landscapes snowmelt occurs when the ground is still frozen; thus frozen soil processes play an important role in snowmelt routing, and, by extension, the timing and magnitude of recharge. This study investigated the vadose zone dynamics governing snowmelt infiltration and groundwater recharge at three grassland sites in the Canadian Prairies over the winter and spring of 2017. The region is characterized by numerous topographic depressions where the ponding of snowmelt runoff results in focused infiltration and recharge. Water balance estimates showed infiltration was the dominant sink (35 %–85 %) of snowmelt under uplands (i.e. areas outside of depressions), even when the ground was frozen, with soil moisture responses indicating flow through the frozen layer. The refreezing of infiltrated meltwater during winter melt events enhanced runoff generation in subsequent melt events. At one site, time lags of up to 3 d between snow cover depletion on uplands and ponding in depressions demonstrated the role of a shallow subsurface transmission pathway or interflow through frozen soil in routing snowmelt from uplands to depressions. At all sites, depression-focused infiltration and recharge began before complete ground thaw and a significant portion (45 %–100 %) occurred while the ground was partially frozen. Relatively rapid infiltration rates and non-sequential soil moisture and groundwater responses, observed prior to ground thaw, indicated preferential flow through frozen soils. The preferential flow dynamics are attributed to macropore networks within the grassland soils, which allow infiltrated meltwater to bypass portions of the frozen soil matrix and facilitate both the lateral transport of meltwater between topographic positions and groundwater recharge through frozen ground. Both of these flow paths may facilitate preferential mass transport to groundwater.


Author(s):  
Mario Pirastru ◽  
Massimo Iovino ◽  
Hassan Awada ◽  
Roberto Marrosu ◽  
Simone Di Prima ◽  
...  

Lateral saturated soil hydraulic conductivity, Ks,l, is the soil property governing subsurface water transfer in hillslopes, and the key parameter in many numerical models simulating hydrological processes both at the hillslope and catchment scales. Likewise, the hydrological connectivity of lateral flow paths plays a significant role in determining the intensity of the subsurface flow at various spatial scales. The objective of the study is to investigate the relationship between Ks,l and hydraulic connectivity at the hillslope spatial scale. Ks,l was determined by the subsurface flow rates intercepted by drains, and by water table depths observed in a well network. Hydraulic connectivity of the lateral flow paths was evaluated by the synchronicity among piezometric peaks, and between the latter and the peaks of drained flow. Soil moisture and precipitation data were used to investigate the influence of the transient hydrological soil condition on connectivity and Ks,l. It was found that the higher was the synchronicity of the water table response between wells, the lower was the time lag between the peaks of water levels and those of the drained subsurface flow. Moreover, the most synchronic water table rises determined the highest drainage rates. The relationships between Ks,l and water table depths were highly non-linear, with a sharp increase of the values for water table levels close to the soil surface. Estimated Ks,l values for the full saturated soil were in the order of thousands of mm h-1, suggesting the activation of macropores in the root zone. The Ks,l values determined at the peak of the drainage events were correlated with the indicators of synchronicity. The sum of the antecedent soil moisture and of the precipitation was correlated with the indicators of connectivity and with Ks,l. We suggest that, for simulating realistic processes at the hillslope scale, the hydraulic connectivity could be implicitly considered in hydrological modelling through an evaluation of Ks,l at the same spatial scale.


2016 ◽  
Author(s):  
Shanshui Yuan ◽  
Steven M. Quiring

Abstract. This study provides a comprehensive evaluation of soil moisture simulations in the Coupled Model Intercomparison Project Phase 5 (CMIP5) extended historical experiment (2003 to 2012). Soil moisture from in situ and satellite sources are used to evaluate CMIP5 simulations in the contiguous United States (CONUS). Both near-surface (0–10 cm) and soil column (0–100 cm) simulations from more than 14 CMIP5 models are evaluated during the warm season (April–September). Multi-model ensemble means and the performance of individual models are assessed at a monthly time scale. Our results indicate that CMIP5 models can reproduce the seasonal variability in soil moisture over CONUS. However, the models tend to overestimate the magnitude of both near-surface and soil-column soil moisture in the western U.S. and underestimate it in the eastern U.S. There are large variations in model performance, especially in the near-surface. There are significant regional and inter-model variations in performance. Results of a regional analysis show that in deeper soil layer, the CMIP5 soil moisture simulations tend to be most skillful in the southern U.S. Based on both the satellite-derived and in situ soil moisture, CESM1, CCSM4 and GFDL-ESM2M perform best in the 0–10 cm soil layer and CESM1, CCSM4, GFDL-ESM2M and HadGEM2-ES perform best in the 0–100 cm soil layer.


2009 ◽  
Vol 6 (6) ◽  
pp. 6895-6928
Author(s):  
L. Wang ◽  
T. Koike ◽  
K. Yang ◽  
R. Jin ◽  
H. Li

Abstract. In this study, a frozen soil parameterization has been modified and incorporated into a distributed biosphere hydrological model (WEB-DHM). The WEB-DHM with the frozen scheme was then rigorously evaluated in a small cold area, the Binngou watershed, against the in-situ observations from the WATER (Watershed Allied Telemetry Experimental Research). In the summer 2008, land surface parameters were optimized using the observed surface radiation fluxes and the soil temperature profile at the Dadongshu-Yakou (DY) station in July; and then soil hydraulic parameters were obtained by the calibration of the July soil moisture profile at the DY station and by the calibration of the discharges at the basin outlet in July and August that covers the annual largest flood peak of 2008. The calibrated WEB-DHM with the frozen scheme was then used for a yearlong simulation from 21 November 2007 to 20 November 2008, to check its performance in cold seasons. Results showed that the WEB-DHM with the frozen scheme has given much better performance than the WEB-DHM without the frozen scheme, in the simulations of soil moisture profile at the DY station and the discharges at the basin outlet in the yearlong simulation.


2011 ◽  
Vol 91 (6) ◽  
pp. 965-968
Author(s):  
B. Wilske ◽  
E. A. Johnson

Wilske, B. and Johnson, E. A. 2011. Measuring unsaturated hydraulic conductivity (K(ψm)) of the F and H soil organic layers at small matric potential (ψm). Can. J. Soil Sci. 91: 965–968. K(ψm) of the soil organic layers is a key parameter to assess water redistribution in cold-climate forests. This study tested the twin suction disc apparatus (TSD) as a new method to measure K(ψm) of the F and H layers directly. We compared the results to two studies. One represents a large data base, the other used similar sample locations; but both derived K(ψm) from combining two methods, i.e., pressure plate measurements combined with the instantaneous profile technique or the constant head approach. The TSD data are consistent with previous results considering the large variability in K(ψm) from the combined methods. This suggests that the TSD method represents an alternative to determine K(ψm) of the soil organic layer.


Water ◽  
2019 ◽  
Vol 11 (6) ◽  
pp. 1235
Author(s):  
Xiaoying Qiao ◽  
Shaoyang Ma ◽  
Guixing Pan ◽  
Guanglu Liu

The soil-water characteristic curve (SWCC) is the basis for obtaining the hydraulic conductivity parameters of a soil as well as for using soil water and heat transport models. At present, the curve can be obtained by two methods: by direct measurement and by empirical formula. Direct measurement is both difficult and time-consuming. By contrast, fitting the SWCC with a suitable empirical formula is stable and convenient. The van Genuchten (VG) model has the advantage of universal applicability due to its use of a statistical aperture distribution model for estimating hydraulic conductivity. This study selected the Mu Us Bottomland as a study area. Data on the water content and water potential of undisturbed soil from this site were obtained with a Ku-pF instrument and a self-designed soil column experiment with temperature settings of 13 °C, 18 °C, 23 °C, 27 °C, and 30 °C. The variation of four main parameters in the VG model with temperature was analyzed based on thermodynamic theory and considering the effect of temperature on soil capillary pressure via its effects on surface tension and contact angle. A prediction model for the soil-water characteristic curve of the Mu Us Bottomland was then constructed, and its applicability was further analyzed. The temperature dependence of the SWCC demonstrated here provides an important scientific basis for agricultural production, farmland water conservancy, and the design of soil and water conservation engineering projects.


Sign in / Sign up

Export Citation Format

Share Document