One of the options to prevent membrane fouling is to implement air lifting that can improve the cake removal from the membrane surface. This study presents the results of tests that were carried out at the Institutes for Desert Research, Kiryat Sde-Boker, Israel, and focused on the influence of hydrodynamic conditions on fouling in a pilot-scale immersed membrane bioreactor (IMBR) using a hollow fiber membrane module of ZW-10 (Zenon Environmental, Canada) under ambient conditions. In this system, the cross-flow velocities across the membrane surface were induced by one conical and four cylindrical draft-tubes. The relationship between the crossflow velocity and the aeration intensity, the influence of the crossflow on fouling rate under various hydrodynamic conditions were investigated and optimal operating conditions were obtained. Optimal operating conditions were reached during the long-term experiment period (70 days) for the treatment of domestic wastewater. The system was stable without external chemical cleaning. The results showed that the permeate was of high quality, and the removal of COD and BOD was 94.0% and 98.8%, respectively.The crossflow near the membrane surface reveals a major contribution for minimizing membrane fouling, and could offer guidelines for future design of similar systems.

Author(s):  
Nina Zhou ◽  
A. G. Agwu Nnanna

Low pressure driven ultrafiltraion (UF) processes has been applied in various industries due to its economical and easy operated benefits. Hollow fiber membrane is one of the most used membrane configuration in industry, membrane fouling is the major challenge for widely usage. Most of the investigation of UF was carried out by experiments to determine the effect of different operating conditions on permeate flux. However, experiments provide limited insight information on the membrane performance. In addition, the prediction of permeate flux under different operating conditions is necessary for experimental design and optimization. The purpose of the present study is to develop a numerical model to simulate the UF process and investigate the UF mechanism. A numerical model was developed using commercial CFD package (FLUENT). The effects of various operating conditions on permeate flux were determined by experiments and simulations, the comparison of the experimental and CFD results shows good agreements. Controlling membrane fouling will maintain a high productivity. The simulations were carried out to investigate the efficiency of removing accumulated particles on membrane surface by installing spacer filaments in membrane channels. The results suggested that the zigzag type spacer has d/h = 0.5 and l/h = 5 is more economical and efficient in reducing fouling.


2011 ◽  
Vol 374-377 ◽  
pp. 951-955
Author(s):  
Xiu Bo Chen ◽  
Zhi Qiang Liu ◽  
Xu Hua Liu ◽  
Gai Jing Yu ◽  
Zhi Hua Zhang

Vertical Anoxic/Oxic Membrane Bioreactor (A/O-MBR) was used to treat domestic sewage. PVDF hollow fiber membrane has been used in MBR. According to the comparison of intercommunity between three non-Newtonian fluid models (Bingham model, Ostwald model and Herschel-Bulkley model) and the test data, the Ostwald model was chose to describe the function relationship between shear intensity and aeration amount. In order to initiating a circulation velocity and to enhancing the scour to the MBR, the traditional aeration method was changed in this experiment. Two baffles were placed on both sides of the membrane modules, and aeration heads were scattered between two baffles. The influence of shear intensity and new aeration method to membrane fouling was investigated in this paper at shear intensity of 20s-1, 40s-1, 60s-1 and 80s-1. The result shows that the stronger shear intensity is, the heavier is the MBR been scoured and the smaller is the change of TMP. The best shear intensity was G=60s-1 after considering all factors comprehensively. Finally, the membrane modules were analyzed by scanning electron microscope (SEM). By the SEM pictures we can see that there are some spots on the membrane surface which deposited by fine grains, EPS and SMP. The spots have different size and location, large scale or compact contamination layer can not been found in the pictures. So it indicates that the changing of aeration method and the controlling of shear intensity has a positive impact on slowing down the membrane fouling.


Water ◽  
2018 ◽  
Vol 10 (8) ◽  
pp. 982 ◽  
Author(s):  
Olga Kulesha ◽  
Zakhar Maletskyi ◽  
Harsha Ratnaweera

Membrane fouling highly limits the development of Membrane bioreactor technology (MBR), which is among the key solutions to water scarcity. The current study deals with the determination of the fouling propensity of filtered biomass in a pilot-scale biofilm membrane bioreactor to enable the prediction of fouling intensity. The system was designed to treat domestic wastewater with the application of ceramic microfiltration membranes. Partial least squares regression analysis of the data obtained during the long-term operation of the biofilm-MBR (BF-MBR) system demonstrated that Mixed liquor suspended solids (MLSS), diluted sludge volume index (DSVI), chemical oxygen demand (COD), and their slopes are the most significant for the estimation and prediction of fouling intensity, while normalized permeability and its slope were found to be the most reliable fouling indicators. Three models were derived depending on the applied operating conditions, which enabled an accurate prediction of the fouling intensities in the system. The results will help to prevent severe membrane fouling via the change of operating conditions to prolong the effective lifetime of the membrane modules and to save energy and resources for the maintenance of the system.


Processes ◽  
2018 ◽  
Vol 6 (5) ◽  
pp. 50 ◽  
Author(s):  
Nsanzumukiza Martin Vincent ◽  
Juan Tong ◽  
Dawei Yu ◽  
Junya Zhang ◽  
Yuansong Wei

2011 ◽  
Vol 63 (9) ◽  
pp. 1906-1912 ◽  
Author(s):  
Simos Malamis ◽  
Andreas Andreadakis ◽  
Daniel Mamais ◽  
Constantinos Noutsopoulos

The aim of this work was to evaluate the long-term performance of a Membrane Bioreactor (MBR) that operated continuously for 2.5 years and to assess membrane fouling and biomass activity under various operating conditions. Furthermore, a method for the characterisation of influent wastewater was developed based on its separation into various fractions. The MBR system operated at the solids retention times (SRT) of 10, 15, 20 and 33 days. The increase of SRT resulted in a decrease of the fouling rate associated with the reduction of extracellular polymeric substances. Moreover, the SRT increase resulted in a significant reduction of the Oxygen Uptake Rate (OUR) due to the lower availability of substrate and in a notable decrease of the maximum OUR since high SRT allowed the development of slower growing microorganisms. Biomass consisted of small flocs due to extensive deflocculation caused by intense aeration. Finally, the method developed for wastewater characterisation is straightforward and less time consuming than the usual method that is employed.


2021 ◽  
Author(s):  
Amira Abdelrasoul

The low-pressure membrane applications are considered to be the most effective and sustainable methods of addressing environmental problems in treating water and wastewater that meets or exceed stringent environmental standards. Nevertheless, membrane fouling is one of the primary operational concerns that is currently hindering a more widespread application of ultrafiltration (UF) with a variety of contaminants. Membrane fouling leads to higher operating costs, higher energy demand, reduced membrane life time, and increased cleaning frequency. As a consequence, an efficient and well-planned UF process is becoming a necessity for consistent and long-term monetary returns. Examining the source and mechanisms of foulant attachment to the membrane’s surface is critical when it comes to the research of membrane fouling and its potential practical implementation. A mathematical model was developed in this study in order to predict the amount of fouling based on an analysis of particle attachments. This model was developed using both homogeneous and heterogeneous membranes, with a uniform and non-uniform pore sizes for the UF of simulated latex effluent with a wide range of particle size distribution. The objective of this mathematical model was to effectively identify and address the common shortcomings of previous fouling models, and to account for the existing chemical attachments in membrane fouling. The mathematical model resulting from this study was capable of accurately predicting the mass of fouling retained by the membrane and the increase in transmembrane pressure (TMP). In addition, predictive models of fouling attachments were derived and now form an extensive set of mathematical models necessary for the prediction of membrane fouling at a given operating condition, as well as, the various membrane surface charges. Polycarbonate and Polysulfone flat membranes, with pore sizes of 0.05 μm and a molecular weight cut off of 60,000 respectively, were used in the experimental designs under a constant feed flow rate and a cross-flow mode in UF of the simulated latex paint effluent. The TMP estimated from the model agreed with the experimentally measured values at different operating conditions, mostly within 5.0 - 8.0 % error, and up to 13.0% error for the uniform, and non-uniform pore size membranes, respectively. Furthermore, different types of membranes with a variety of molecular weight cut-off (MWCO) values were tested so as to evaluate the accuracy of the models for a generalized application. In addition , a power consumption model, incorporating fouling attachment as well as chemical and physical factors in membrane fouling, was developed in order to ensure accurate prediction and scale-up. Innovative remediation techniques were likewise developed and applied in order to minimize membrane fouling, enhance the membrane performance, and save energy. Fouling remediation methodologies included the pre-treating of the latex effluent, so as to limit its fouling propensity by using different types of surfactants as cationic and anionic, in addition to the pH change. The antifouling properties of the membranes were improved through the implementation of the membrane pH treatment and anionic surfactant treatment. Increasing the ionic strength of latex effluent or enhancing the membrane surface hydrophilicity facilitated a significant increase in the cumulative permeate flux, a substantial decrease in the total mass of fouling, and a noticeable decrease in the specific power consumption.


2021 ◽  
Author(s):  
Amira Abdelrasoul

The low-pressure membrane applications are considered to be the most effective and sustainable methods of addressing environmental problems in treating water and wastewater that meets or exceed stringent environmental standards. Nevertheless, membrane fouling is one of the primary operational concerns that is currently hindering a more widespread application of ultrafiltration (UF) with a variety of contaminants. Membrane fouling leads to higher operating costs, higher energy demand, reduced membrane life time, and increased cleaning frequency. As a consequence, an efficient and well-planned UF process is becoming a necessity for consistent and long-term monetary returns. Examining the source and mechanisms of foulant attachment to the membrane’s surface is critical when it comes to the research of membrane fouling and its potential practical implementation. A mathematical model was developed in this study in order to predict the amount of fouling based on an analysis of particle attachments. This model was developed using both homogeneous and heterogeneous membranes, with a uniform and non-uniform pore sizes for the UF of simulated latex effluent with a wide range of particle size distribution. The objective of this mathematical model was to effectively identify and address the common shortcomings of previous fouling models, and to account for the existing chemical attachments in membrane fouling. The mathematical model resulting from this study was capable of accurately predicting the mass of fouling retained by the membrane and the increase in transmembrane pressure (TMP). In addition, predictive models of fouling attachments were derived and now form an extensive set of mathematical models necessary for the prediction of membrane fouling at a given operating condition, as well as, the various membrane surface charges. Polycarbonate and Polysulfone flat membranes, with pore sizes of 0.05 μm and a molecular weight cut off of 60,000 respectively, were used in the experimental designs under a constant feed flow rate and a cross-flow mode in UF of the simulated latex paint effluent. The TMP estimated from the model agreed with the experimentally measured values at different operating conditions, mostly within 5.0 - 8.0 % error, and up to 13.0% error for the uniform, and non-uniform pore size membranes, respectively. Furthermore, different types of membranes with a variety of molecular weight cut-off (MWCO) values were tested so as to evaluate the accuracy of the models for a generalized application. In addition , a power consumption model, incorporating fouling attachment as well as chemical and physical factors in membrane fouling, was developed in order to ensure accurate prediction and scale-up. Innovative remediation techniques were likewise developed and applied in order to minimize membrane fouling, enhance the membrane performance, and save energy. Fouling remediation methodologies included the pre-treating of the latex effluent, so as to limit its fouling propensity by using different types of surfactants as cationic and anionic, in addition to the pH change. The antifouling properties of the membranes were improved through the implementation of the membrane pH treatment and anionic surfactant treatment. Increasing the ionic strength of latex effluent or enhancing the membrane surface hydrophilicity facilitated a significant increase in the cumulative permeate flux, a substantial decrease in the total mass of fouling, and a noticeable decrease in the specific power consumption.


2012 ◽  
Vol 66 (12) ◽  
pp. 2505-2516 ◽  
Author(s):  
J. M. Ochando-Pulido ◽  
A. Martinez-Ferez

Direct disposal of the heavily polluted effluent from olive oil industry (olive mill wastewater, OMW) to the environment or to domestic wastewater treatment plants is actually prohibited in most countries, and conventional treatments are ineffective. Membranes are currently one of the most versatile technologies for environmental quality control. Notwithstanding, studies on OMW reclamation by membranes are still scarce, and fouling inhibition and prediction to improve large-scale membrane performance still remain unresolved. Consequently, adequately targeted pretreatment for the specific binomium membrane-feed, as well as optimized operating conditions for the proper membranes, is today's challenge to ensure threshold flux values. Several membrane materials, configurations and pore sizes have been elucidated, and also different pretreatments including sedimentation, centrifugation, biosorption, sieving, filtration and microfiltration, various types of flocculation as well as advance oxidation processes have been applied so far. Recovery of potential-value compounds, such as a variety of polyphenols highlighting oleuropein and hydroxytyrosol, has been attempted too. All this research should constitute the starting point to proceed with OMW purification beyond recycling for irrigation or depuration for sewer discharge, with the aim of complying with standards to reuse the effluent in the olive oil production process, together with cost-effective recovery of added-value compounds.