Specific SBR population behaviour as revealed by comparative dynamic simulation analysis of three full-scale municipal SBR wastewater treatment plants

2006 ◽  
Vol 54 (1) ◽  
pp. 71-80 ◽  
Author(s):  
S.G.E. Rönner-Holm ◽  
A. Mennerich ◽  
N.C. Holm

Three full-scale municipal sequential batch reactor (SBR) wastewater treatment plants (WWTPs) were investigated by dynamic simulation studies using ASM1.All three WWTPs showed similar kinetic and stoichiometric conditions in the SBR population behaviour after calibration of the models. The simulation results detected only a discrepancy to the ammonia online data during and shortly after shock loading under anoxic and anaerobic conditions that so far could not be adjusted by the ASM1 model. However, these differences did not severely affect the quality of the simulations nor the effluent flows. Additionally, in all cases a dynamic alpha factor curve occurred during the aeration phases that was verified by further oxygen transfer measurements. This might reveal new aspects for the process control, design and simulation of SBR WWTPs. A short lag phase was detected in many cases at the beginning of the first aeration phase.

1996 ◽  
Vol 33 (1) ◽  
pp. 81-87
Author(s):  
L. Van Vooren ◽  
P. Willems ◽  
J. P. Ottoy ◽  
G. C. Vansteenkiste ◽  
W. Verstraete

The use of an automatic on-line titration unit for monitoring the effluent quality of wastewater plants is presented. Buffer capacity curves of different effluent types were studied and validation results are presented for both domestic and industrial full-scale wastewater treatment plants. Ammonium and ortho-phosphate monitoring of the effluent were established by using a simple titration device, connected to a data-interpretation unit. The use of this sensor as the activator of an effluent quality proportional sampler is discussed.


Vestnik MGSU ◽  
2019 ◽  
pp. 589-602 ◽  
Author(s):  
Tran Ha Quan ◽  
Elena S. Gogina

Introduction. Vietnamese urban municipal wastewater treatment plants are mainly of aeration-type facilities. Nowadays, an aeration-type plant, the Sequencing Batch Reactor (SBR), is widely applied and possesses a number of advantages over traditional systems with suspended activated sludge. Advantages of the SBR are mainly concluded in simplicity of operation, occupied area and cost. There is a number of problems at the wastewater treatment plants; they are connected with supplying only a half of wastewater design amount for the treatment as well as with quality of the purified water that must satisfy requirements of the Vietnamese discharge standard, the Standard A. Therefore, reconstruction and modification of the SBR is the major challenger to ensure the sustained development of large Vietnamese cities and maintenance of ecological balance. Materials and methods. To enhance the efficiency of wastewater purification in the SBR, the experiments were set on reactor reconstruction and modification by two directions: (1) Technological method, i.e. applying the Biochip 25 biocarrier, and (2) Operation method, i.e. adding the anoxic phase in reactor operation cycle. Laboratory tests were conducted for each of the directions, including comparison of a typical reactor with the modified one. Results. The study resulted in obtaining an optimal amount of the BioChip biocarrier material (10 to 20 %) that increased efficiency of wastewater purification by 10 to 20 %. In addition to this, when creating an anoxic phase of the operation cycle, efficiency of nitrogen removal increased by 20 %. When the denitrification occurs under the anoxic conditions, it contributes to stabilization of ammonium nitrogen removal for daily nitrogen loading in reactor of 0.3 to 0.8 TKN kg/sludge kg. Conclusions. The suggested technology provides the quality of treated water corresponding with the Vietnamese Standard A requirements. At the present, it is planned to proceed with the experiment on the base of Vietnamese semi-industrial plant for research and appraisal of the SBR reconstruction and modification method. Acknowledgements. The authors are grateful to AKVA Control company in Samara for granted biocarrier Mutag BioChip 25 and to Associate Professor Tran Van Quang and his students, Nguyen Ngoc Phuong and Truong Quoc Dai, of Environment Protect Research Center, Danang University for support of the experiment.


2016 ◽  
Vol 18 (3) ◽  
pp. 406-416 ◽  
Author(s):  
Khalid Muzamil Gani ◽  
Ankur Rajpal ◽  
Absar Ahmad Kazmi

The contamination level of four phthalates in untreated and treated wastewater of fifteen wastewater treatment plants (WWTPs) and their fate in a full scale sequencing batch reactor (SBR) based WWTP was evaluated in this study.


2013 ◽  
Vol 67 (9) ◽  
pp. 1887-1893 ◽  
Author(s):  
Shichang Sun ◽  
Xiang Cheng ◽  
Sha Li ◽  
Fei Qi ◽  
Yan Liu ◽  
...  

The emission of nitrous oxide (N2O) from full-scale anoxic/anaerobic/oxic (A2O) and sequencing batch reactor (SBR) processes was measured to evaluate N2O emission from urban wastewater treatment plants (WWTPs). The results showed that N2O flux in the A2O WWTP followed an order of A2O-oxic zone > aerated grit tank >> A2O-anaerobic zone > A2O-anoxic zone > final clarifier > primary clarifier, while in the SBR WWTP the order was SBR tank >> swirl grit tank > wastewater distribution tank and within the SBR tank in an order of SBR-feeding period > SBR-aeration period > SBR-settling period > SBR-decanting period. N2O emission from the A2O WWTP was approximately 486.61 kg d−1, 96.9% of which was from the A2O-oxic zone. In the SBR WWTP, the emission of N2O was 339.24 kg d−1 with 99.9% of the total emission coming from the periods of feeding and aeration. There was 6.52% of nitrogen-load in the influent being transformed to the emitted N2O in the SBR WWTP; the percentage was 3.35 times higher than that in the A2O WWTP.


2009 ◽  
Vol 59 (1) ◽  
pp. 133-140 ◽  
Author(s):  
J. Alex ◽  
N. C. Holm ◽  
S. G. E. Rönner-Holm

In five full-scale municipal sequential batch reactor (SBR) wastewater treatment plants (WWTPs) indications for lag phases, a dynamic alpha factor and ammonium adsorption behaviour of the activated sludge were found. A dynamic simulation analysis of all WWTPs showed the need to implement these characteristics into the model in order to improve the calibration procedure, to meet better results for optimisation studies and even to calculate better fitting running costs including the aeration energy. Even if these effects could be characterised as minor effects, it is planned to utilise the knowledge about these effects for further optimisation of the SBR process and to achieve significant improvements.


2009 ◽  
Vol 60 (5) ◽  
pp. 1161-1172 ◽  
Author(s):  
S. G. E. Rönner-Holm ◽  
N. C. Holm

Dynamic simulation analyses of five different sequencing batch reactor (SBR) wastewater treatment plants (WWTPs) were used in order to optimise developed regulation strategies and to develop new strategies. The results were applied directly to 15 full-scale SBR plants. To do this, the cycle strategies were extended through the use of appropriate aggregates, or were anchored in the programmable logic controller (PLC) and process control system (PCS) with the help of online sensors. This enabled all regulation strategies to be introduced and automated without problems.


Water SA ◽  
2019 ◽  
Vol 45 (3 July) ◽  
Author(s):  
V Bakos ◽  
A Deák ◽  
A Jobbágy

Success of design and high operational efficiency may basically stand or fall on the quality of measured (or estimated) input data. Even small mistakes committed in the initial steps of sampling and analysis may become large once scaled up in the design process or during full-scale operation. The paper provides several experiment-based practical recommendations and easily implemented, powerful methods for appropriate sampling and analysis practice in wastewater treatment. Representative wastewater characterization is crucial for satisfactory design and cost-effective operation. The paper highlights hidden problems and challenges of sampling and analysis in activated sludge wastewater treatment which may strongly affect the quality of input data, and thus basically determine the modelling outputs. Full-scale results proved that wastewater quality may change significantly in the sampling tubing and vessels; during the sampling process even nitrification can happen. Regarding sludge settling measurements, effects of dilution, temperature, floc structure, nitrate and dissolved oxygen concentrations as well as current biochemical condition of the sludge sample have been studied and important recommendations provided. A combined comparative method including SVI and DSVI measurements has been elaborated for indication and early warning alert of undesired floc structure transformations. Influent BOD5 concentration is a key factor for describing biodegradability and denitrification capacity of wastewater to be treated. Results of the two most commonly used BOD testing methods were compared for preclarified wastewater. An electrochemical measurement technique provided significantly lower BOD5 concentrations compared to manometric analysis results with a difference of 23% and 15% on average for unfiltered and filtered samples, respectively. Effects of BOD-based fractionation deviations on predictable denitrification efficiency were studied at different inlet C/N ratios by simulating existing full-scale wastewater treatment plants resulting in remarkable differences in effluent nitrate concentrations. Based on the results, application of the manometric BOD measurement method proved to be preferable.


2016 ◽  
Vol 74 (9) ◽  
pp. 2010-2020
Author(s):  
Liancheng Xiang ◽  
Junqi Wu ◽  
Yonghui Song ◽  
Ruixia Liu ◽  
Huibin Yu ◽  
...  

The wastewater quality of several municipal wastewater treatment plants (MWTPs) in Beijing was studied, and the water densities of different processing units were also measured during the wastewater treatment process. The results clearly showed that the water density declined from influent to effluent of the wastewater treatment process. Meanwhile, the variation in water density had good statistical correlation with the concentrations of total organic carbon, total phosphorus, suspended solids and total solids. Furthermore, the variation in water density could be used to explain the working principles of the Unifed sequencing batch reactor (SBR). Tracer tests were conducted in the Unifed SBR to investigate the hydraulic characteristics of the reactor. The experimental results showed that the variable values of water density from influent to effluent in the Fangzhuang MWTPs were greater than those caused by the temperature difference of >3 °C between the influent and the liquid in the reactor at 13 °C. Moreover, the flow regime of wastewater in the Unifed SBR was affected by the variation in water density, which may lead to stratification or a density current. Ascribed to the appearance of stratification in the Unifed SBR reactor, the water quality of the effluent could not be affected by that of the influent.


1993 ◽  
Vol 28 (11-12) ◽  
pp. 257-261
Author(s):  
M. Truett Garrett ◽  
Zaki Ahmad ◽  
Shelly Young

The recent requirements by U.S.E.P.A. for dechlorination and biomonitoring have increased the importance of automatic control of effluent chlorination in wastewater treatment plants. Difficulties with the Ziegler-Nichols controller tuning procedure were reported at the Kyoto Workshop, 1990. Problems are caused by the noise of incomplete mixing, a long time constant, and the disturbances of changing flow and chlorine demand. The Astrom-Hagglund relay feedback procedure provides acceptable control while data is logged to determine the controller constants. Experiences in using the procedure in existing facilities (not redesigning the mixing point) and the quality of control are presented.


1982 ◽  
Vol 47 (2) ◽  
pp. 430-445
Author(s):  
Josef Horák ◽  
Zina Valášková

An algorithm has been developed and on a mathematical model analyzed to stabilize the reaction temperature of a batch reactor. The reaction has been a zero-order one and the reactor has been operated in a instable operating point. The action variable is the heat exchange surface whose area is increased if the temperature is above, or decreased if the temperature is below the set point. The following two-point regulators have been studied: An ideal relay, a relay with hysteresis and an asymmetric PD relay. The effect has been discussed of the parameters of the regulators on the quality of regulation. Stability analysis has been made of the stationary switching cycles and the domains of applicability have been determined for individual regulators with respect to the rate of change of the area of heat exchange surface.


Sign in / Sign up

Export Citation Format

Share Document