Comparison of methods for the determination of KLaO2 for respirometric measurements

2004 ◽  
Vol 50 (11) ◽  
pp. 153-161 ◽  
Author(s):  
S. Pratt ◽  
R. Zeng ◽  
Z. Yuan ◽  
J. Keller

The mass transfer coefficient for oxygen in water (KLaO2) is an important parameter for respirometric studies. But determination of KLaO2 in process conditions is not straightforward. In this paper, two distinct procedures for determining KLaO2 in process conditions are outlined and tested. The off-gas method relies on a gas mass balance over a bioreactor while the non-steady state methods rely on analysing DO recovery after perturbation. Various means for inducing perturbation are tested and compared. KLaO2 values for a bioreactor are determined by the listed methods. It was found that the off-gas method resulted in the highest KLaO2 for the given reactor, while the non-steady state method, whereby perturbation is caused by exogenous activity on acetate, resulted in the lowest KLaO2. It is shown that the gas mass balancing technique is robust to unexpected exogenous activity (caused by for example, the oxidation of storage polymers formed or nitrite accumulated), while the non-steady state methods that involve inducing perturbations by exogenous activity appear susceptible to such continued exogenous activity in the DO recovery period.

1985 ◽  
Vol 17 (2-3) ◽  
pp. 303-311
Author(s):  
Kees de Korte ◽  
Peter Smits

The usual method for OC measurement is the non-steady state method (reaeration) in tapwater or, sometimes, in activated sludge. Both methods are more or less difficult and expensive. The steady state method with activated sludge is presented. Fundamentals are discussed. For complete mixed aeration tanks, plug flow systems with diffused air aeration and carousels the method is described more in detail and the results of measurements are presented. The results of the steady state measurements of the diffused air system are compared with those of the reaeration method in tapwater. The accuracy of the measurements in the 3 systems is discussed. Measurements in other aeration systems are described briefly. It is concluded that the steady state OC measurement offers advantages in comparison with the non-steady state method and is useful for most purposes.


2018 ◽  
Vol 8 (9) ◽  
pp. 1670 ◽  
Author(s):  
Wei Zhong ◽  
Xiang Ji ◽  
Chong Li ◽  
Jiwen Fang ◽  
Fanghua Liu

Sintered metal porous media are widely used in a broad range of industrial equipment. Generally, the flow properties in porous media are represented by an incompressible Darcy‒Forchheimer regime. This study uses a modified Forchheimer equation to represent the flow rate characteristics, which are then experimentally and theoretically investigated using a few samples of sintered metal porous media. The traditional steady-state method has a long testing time and considerable air consumption. With this in mind, a discharge method based on an isothermal chamber filled with copper wires is proposed to simultaneously determine the permeability and inertial coefficient. The flow rate discharged from the isothermal chamber is calculated by differentiating the measured pressure, and a paired dataset of pressure difference and flow rate is available. The theoretical representations of pressure difference versus flow rate show good agreement with the steady-state results. Finally, the volume limit of the isothermal chamber is addressed to ensure sufficient accuracy.


Sign in / Sign up

Export Citation Format

Share Document