Energy saving processes for nitrogen removal in organic wastewater from food processing industries in Thailand

2004 ◽  
Vol 50 (6) ◽  
pp. 345-351 ◽  
Author(s):  
N.H. Johansen ◽  
N. Suksawad ◽  
P. Balslev

Nitrogen removal from organic wastewater is becoming a demand in developed communities. The use of nitrite as intermediate in the treatment of wastewater has been largely ignored, but is actually a relevant energy saving process compared to conventional nitrification/denitrification using nitrate as intermediate. Full-scale results and pilot-scale results using this process are presented. The process needs some additional process considerations and process control to be utilized. Especially under tropical conditions the nitritation process will round easily, and it must be expected that many AS treatment plants in the food industry already produce NO2-N. This uncontrolled nitrogen conversion can be the main cause for sludge bulking problems. It is expected that sludge bulking problems in many cases can be solved just by changing the process control in order to run a more consequent nitritation. Theoretically this process will decrease the oxygen consumption for oxidation by 25% and the use of carbon source for the reduction will be decreased by 40% compared to the conventional process.

1995 ◽  
Vol 32 (3) ◽  
pp. 263-270 ◽  
Author(s):  
Seni Karnchanawong ◽  
Jaras Sanjitt

Two pilot-scale studies were comparatively conducted under tropical conditions during December 1992 to September 1993. One study involved facultative ponds(FP) and the others water spinach ponds(SP). Four rectangular concrete ponds, 0.8 m × 2.4 m × 1.1 m (width × length × depth), were employed to treat the Chiang Mai University campus wastewater. Water spinach (Ipomoea aquatica) was planted in two of the ponds. The influent characteristics noted showed a low organic content, i.e. BOD 25.4-29.9 mg/l, with BOD:N ratio around 1:1. The investigations were conducted using the following hydraulic retention times (HRT): 1.6, 2, 2.7, 4, 8 and 16 d. The results showed that the BOD, COD and SS mass removal rates increased as the mass loading rates increased and the SP was significantly more effective in reducing the organic content than the FP. No relationship was found between TN mass removal and the loading rates. However, the TP mass removal rates in the SP and the FP were rather low and were considered to be insignificant. It was observed that SS accumulated in the water spinach root systems which tended to act as a strainer. This process led to plant growth inhibition and finally die-off. The average water spinach growth rates varied from 37 to 107 g wet wt./(m2.d) and no relationship was established between the growth rates and the HRT.


2010 ◽  
Vol 62 (8) ◽  
pp. 1965-1965
Author(s):  
S. Park ◽  
J. Lee ◽  
J. Park ◽  
I. Byun ◽  
T. Park ◽  
...  

Publisher‘s note. We regret that the published version of this article erroneously denoted the first author as corresponding author; in fact the formal corresponding author of this paper is Professor Taeho Lee, whose address is repeated below.


2017 ◽  
Vol 77 (1) ◽  
pp. 70-78 ◽  
Author(s):  
Yanjun Mao ◽  
Xie Quan ◽  
Huimin Zhao ◽  
Yaobin Zhang ◽  
Shuo Chen ◽  
...  

Abstract The activated sludge (AS) process is widely applied in dyestuff wastewater treatment plants (WWTPs); however, the nitrogen removal efficiency is relatively low and the effluent does not meet the indirect discharge standards before being discharged into the industrial park's WWTP. Hence it is necessary to upgrade the WWTP with more advanced technologies. Moving bed biofilm processes with suspended carriers in an aerobic tank are promising methods due to enhanced nitrification and denitrification. Herein, a pilot-scale integrated free-floating biofilm and activated sludge (IFFAS) process was employed to investigate the feasibility of enhancing nitrogen removal efficiency at different hydraulic retention times (HRTs). The results showed that the effluent chemical oxygen demand (COD), ammonium nitrate (NH4+-N) and total nitrogen (TN) concentrations of the IFFAS process were significantly lower than those of the AS process, and could meet the indirect discharge standards. PCR-DGGE and FISH results indicated that more nitrifiers and denitrifiers co-existed in the IFFAS system, promoting simultaneous nitrification and denitrification. Based on the pilot results, the IFFAS process was used to upgrade the full-scale AS process, and the effluent COD, NH4+-N and TN of the IFFAS process were 91–291 mg/L, 10.6–28.7 mg/L and 18.9–48.6 mg/L, stably meeting the indirect discharge standards and demonstrating the advantages of IFFAS in dyestuff wastewater treatment.


2010 ◽  
Vol 61 (5) ◽  
pp. 1137-1146 ◽  
Author(s):  
M. A. Camargo Valero ◽  
L. F. Read ◽  
D. D. Mara ◽  
R. J. Newton ◽  
T. P. Curtis ◽  
...  

A pilot-scale primary maturation pond was spiked with 15N-labelled ammonia (15NH4Cl) and 15N-labelled nitrite (Na15NO2), in order to improve current understanding of the dynamics of inorganic nitrogen transformations and removal in WSP systems. Stable isotope analysis of δ15N showed that nitrification could be considered as an intermediate step in WSP, which is masked by simultaneous denitrification, under conditions of low algal activity. Molecular microbiology analysis showed that denitrification can be considered a feasible mechanism for permanent nitrogen removal in WSP, which may be supported either by ammonia-oxidising bacteria (AOB) or by methanotrophs, in addition to nitrite-oxidising bacteria (NOB). However, the relative supremacy of the denitrification process over other nitrogen removal mechanisms (e.g., biological uptake) depends upon phytoplanktonic activity.


Entecho ◽  
2019 ◽  
Vol 2 (1) ◽  
pp. 1-5
Author(s):  
Vojtěch Kouba ◽  
Jan Bartáček

Proces částečná nitritace-anammox odstraňuje amoniakální dusík z odpadních vod s polovičními náklady na aeraci, až o 80 % nižší produkcí přebytečného kalu a bez spotřeby organického substrátu. Jde o zavedený proces pro odstraňování dusíku z kalových vod z anaerobní fermentace, a podobně koncentrovaných a teplých odpadních vod. Na tyto vody se částečná nitritace-anammox aplikuje již déle než deset let, a to např. pod názvy ANAMMOX®, ANITA™ Mox, DEMON®, nebo TERRAMOX®. Optimalizované provozy těchto technologií dusík běžně odstraňují při zatížení 0,5–2,3 kg∙m–3∙d–1 (30–35 °C). Současnou výzvou pro výzkum je implementace částečné nitritace-anammox do hlavního proudu studené splaškové odpadní vody, přičemž konkrétními problémy jsou (i) potlačení nežádoucích nitratačních mikroorganismů (NOB) a (ii) adaptace mikroorganismů anammox na nízké teploty. Náš výzkum jsme začali s jednostupňovým procesem, a poté nitritaci a anammox rozdělili do dvou reaktorů. Prezentujeme strategii, která v laboratorním měřítku NOB účinně potlačila i při 12 °C a dále i v pilotním měřítku při 13–30 °C. Dále ukazujeme, že anammox je možné na nízké teploty adaptovat studenými šoky. Tyto výsledky umožní rozšířit úsporné odstraňování dusíku i do hlavního proudu splaškové odpadní vody na ČOV. English: Partial nitritation-anammox (PN/A) process removes nitrogen from wastewater with 50% reduction of aeration costs, 80% less excess sludge and no consumption of organic carbon. PN/A is an established process for the removal of nitrogen from reject water from anaerobic digestion and other similarly warm and concentrated streams. On such wastewater, PN/A has been applied in full scale for over 10 years under names such as ANAMMOX®, ANITA™ Mox, DEMON® or TERRAMOX®, whose optimized installations consistently achieve nitrogen removal loading rates of 0,5–2,3 kg∙m–3∙d–1. The current challenge for research is to implement PN/A into the main stream of cold municipal wastewater, the specific challenges being (i) suppression of undesirable nitrite oxidizing bacteria (NOB) and (ii) adaptation of anammox microorganisms to low temperatures. Our initial experiences with one-stage PN/A in the main stream led us to the separation of PN/A in two subsequent reactors. Subsequently, we developed a strategy for NOB suppression in partial nitritation even under 12 °C, which we then successfully tested in the pilot scale. Furthermore, we found that anammox can be adapted to low temperatures using cold shocks. In sum, these results will enable extending the savings for nitrogen removal into the main stream of wastewater at WWTP.


Sign in / Sign up

Export Citation Format

Share Document