Anaerobic hydrolysis of a municipal wastewater in a pilot-scale digester

2003 ◽  
Vol 47 (12) ◽  
pp. 223-230 ◽  
Author(s):  
J.A. Álvarez ◽  
C.A. Zapico ◽  
M. Gómez ◽  
J. Presas ◽  
M. Soto

Raw domestic wastewater from the city of Santiago de Compostela (Northwest Spain) was fed into a pilot-scale hydrolytic up flow sludge bed (HUSB) digester with an active volume of 25.5 m3. The total influent chemical oxygen demand (COD) ranged from 360 to 470 mg/l, the influent SS varied from 190 to 370 mg/l, and the temperature was between 17° and 20°C. The organic load rate (OLR) applied increased step by step from 1.2 to 3.9 kgCOD/m3.d, while the hydraulic retention time (HRT) decreased from 7.1 h to 2.9 h. A high suspended solids (SS) removal of about 82-85% from the influent was reached, most of which (81 to 88%) was eliminated by hydrolysis, while the rest remained in the purge stream. The total COD removal ranged from 46 to 59%. On the other hand, a high acidification of the COD remaining in the effluent was obtained, so the percent COD in the form of volatile fatty acids (VFACOD) with respect to total effluent COD was about 43% for the highest HRT applied, and about 27% for the lowest HRT. The soluble to total COD ratio (CODs/CODt) increased from 25-32% for the influent to 71-86% for the effluent. The results obtained confirm the viability and interest of direct anaerobic hydrolytic pre-treatment of domestic wastewater.

2006 ◽  
Vol 53 (3) ◽  
pp. 209-218 ◽  
Author(s):  
M. Tandukar ◽  
S. Uemura ◽  
A. Ohashi ◽  
H. Harada

A “fourth generation” down-flow hanging sponge (DHS) Reactor has been developed and proposed as an improved variant of post-treatment system for UASB treating domestic wastewater. This paper evaluates the potential of the proposed combination of UASB and DHS as a sewage treatment system, especially for developing countries. A pilot-scale UASB (1.15 m3) and DHS (0.38 m3; volume of sponge) was installed in a municipal sewage treatment site and constantly monitored for 2 years. UASB was operated at an HRT of 6 h corresponding to an organic load of 2.15 kg-COD/m3 per day. Subsequently, the organic load in DHS was 2.35 kg-COD/m3 per day, operated at an HRT of 2 h. Organic removal by the whole system was satisfactory, accomplishing 96% of unfiltered BOD removal and 91% of unfiltered COD removal. However, nitrification decreased from 56% during the startup period to 28% afterwards. Investigation on DHS sludge was made by quantifying it and evaluating oxygen uptake rates with various substrates. Average concentration of trapped biomass was 26 g-VSS/L of sponge volume, increasing the SRT of the system to 100–125 d. Removal of coliforms obtained was 3–4 log10 with the final count of 103 to 104 MPN/100 ml in DHS effluent.


2021 ◽  
Vol 39 (1A) ◽  
pp. 130-136
Author(s):  
Khairi R. Kalash ◽  
Majid A. Dixon ◽  
Hussein IR. Sultan ◽  
Raad A. Ali

In this work, the Upflow Anaerobic Sludge Blanket “UASB” reactor treated effluent wastewater to investigate the process performance on a pilot plant scale. Municipal wastewater at high and medium strength with different organic load rate OLR (0.6-9) kg COD m-3day-1 with the flow of 20 l/h, up-flow velocity 0.4 m/h, hydraulic retention time HRT 9 h at a temperature of (20-30 ºC) was evaluated. The wastewater concentration, including TSS, COD was measured, and the removal efficiencies of chemical oxygen demand (COD) and total suspended solid TSS were calculated and summarized as 45-85% and 70-75%, respectively, depending on organic load rate OLR. Effluent volatile fatty acids VFA was measured, and the results were in the range between 12-90 mg/L depending on OLR with a slight change in pH (8.3-8.4), which means the conversion of COD to methane and increase ammonia concentration.


Water ◽  
2020 ◽  
Vol 12 (10) ◽  
pp. 2771
Author(s):  
Jian Wang ◽  
Cong Du ◽  
Feng Qian ◽  
Yonghui Song ◽  
Liancheng Xiang

A pilot-scale experiment is carried out for treating mixed wastewater containing pharmaceutical wastewater (PW) and domestic wastewater (DW), by a process that is a combination of hydrolysis acidification-ozone-modified anaerobic–anoxic–aerobic-ozone (A2/O) (pre-ozone) or hydrolysis acidification-modified A2/O-ozone (post-ozone). The effects of different mixing ratios of PW and DW and pre-ozone treatment or post-ozone treatment on the removal of nitrogen and phosphorus and chemical oxygen demand (COD) are compared and studied. The optimal ratio of PW in mixing wastewater is 30%, which has the optimal COD removal efficiency and minimum biotoxicity to biological treatment. The pre-ozone treatment shows more advantages in removing nitrogen and phosphate but the post-ozone treatment shows more advantages in COD removal. Analysis of dissolved organic matter (DOM) demonstrates that post-ozone treatment has a more significant effect on the removal of fulvic acid and humic acid than the effect from the pre-ozone treatment, so the COD removal is better. Overall DOM degradation efficiency by post-ozone treatment is 55%, which is much higher than the pre-ozone treatment efficiency of 38%. Microbial community analysis reveals that the genus Thauera and the genus Parasegetibacter take great responsibility for the degradation of phenolics in this process. All the results show that the post-ozone treatment is more efficient for the mixed wastewater treatment in refractory organics removal.


Processes ◽  
2019 ◽  
Vol 7 (9) ◽  
pp. 635 ◽  
Author(s):  
Siciliano ◽  
Limonti ◽  
Curcio ◽  
Calabrò

The composting process of organic fraction of municipal solid waste, besides to the residual compost, generates a wastewater that is characterized by a high organic load. The application of anaerobic processes represents an advantageous solution for the treatment and valorization of this type of wastewater. Nevertheless, few works have been focused on the anaerobic digestion of compost leachate. To overcome this dearth, in the present paper an extensive experimental investigation was carried out to develop and analyse the anaerobic treatment of young leachate in completely stirred tank reactors (CSTR). Initially, it was defined a suitable leachate pretreatment to correct its acidic characteristics that is potentially able to inhibit methanogenic biomass activity. The pretreated leachate was fed to the digester over the start-up phase that was completed in about 40 days. During the operational period, the organic load rate (OLR) changed between 4.25 kgCOD/m3d and 38.5 kgCOD/m3d. The chemical oxygen demand (COD) abatement was higher than 90% for OLR values up to 14.5 kgCOD/m3d and around to 80% for applied loads equal to 24.5 kgCOD/m3d. At this OLR, it was reached the maximum daily biogas production of about 9.3 Lbiogas/(Lreactord). The CH4 fraction was between 70%–78% and the methane production yield in the range 0.34–0.38 LCH4/gCODremoved. The deterioration of biogas production started for OLR values that were over the threshold of 24.5 kgCOD/m3d when a volatile fatty acids (VFA) accumulation occurred and the pH dropped below 6.5. The maximum ratio between VFA and alkalinity (ALK) tolerable in the CSTR was identified to be 0.5 gCH3COOH/gCaCO3. Through an economic analysis, it was proven that the digestion of compost leachate could ensure significant economic profits. Furthermore, the produced digestate had characteristics that were compatible for agricultural applications.


2021 ◽  
Vol 11 (2) ◽  
pp. 510
Author(s):  
Elza R. Mikheeva ◽  
Inna V. Katraeva ◽  
Andrey A. Kovalev ◽  
Dmitriy A. Kovalev ◽  
Alla N. Nozhevnikova ◽  
...  

This article presents the results of the start-up of continuous production of biohydrogen from cheese whey (CW) in an anaerobic filter (AF) and anaerobic fluidized bed (AFB) with a polyurethane carrier. Heat and acid pretreatments were used for the inactivation of hydrogen-scavengers in the inoculum (mesophilic and thermophilic anaerobic sludge). Acid pretreatment was effective for thermophilic anaerobic sludge to suppress methanogenic activity, and heat treatment was effective for mesophilic anaerobic sludge. Maximum specific yields of hydrogen, namely 178 mL/g chemical oxygen demand (COD) and 149 mL/g COD for AFB and AF, respectively, were obtained at the hydraulic retention time (HRT) of 4.5 days and organic load rate (OLR) of 6.61 kg COD/(m3 day). At the same time, the maximum hydrogen production rates of 1.28 and 1.9 NL/(L day) for AF and AFB, respectively, were obtained at the HRT of 2.02 days and OLR of 14.88 kg COD/(m3 day). At the phylum level, the dominant taxa were Firmicutes (65% in AF and 60% in AFB), and at the genus level, Lactobacillus (40% in AF and 43% in AFB) and Bifidobacterium (24% in AF and 30% in AFB).


2013 ◽  
Vol 67 (9) ◽  
Author(s):  
Karina Michalska ◽  
Stanisław Ledakowicz

AbstractThis work studies the influence of the alkali pre-treatment of Sorghum Moench — a representative of energy crops used in biogas production. Solutions containing various concentrations of sodium hydroxide were used to achieve the highest degradation of lignocellulosic structures. The results obtained after chemical pre-treatment indicate that the use of NaOH leads to the removal of almost all lignin (over 99 % in the case of 5 mass % NaOH) from the biomass, which is a prerequisite for efficient anaerobic digestion. Several parameters, such as chemical oxygen demand, total organic carbon, total phenolic content, volatile fatty acids, and general nitrogen were determined in the hydrolysates thus obtained in order to define the most favourable conditions. The best results were obtained for the Sorghum treated with 5 mass % NaOH at 121°C for 30 min The hydrolysate thus achieved consisted of high total phenolic compounds concentration (ca. 4.7 g L−1) and chemical oxygen demand value (ca. 45 g L−1). Although single alkali hydrolysis causes total degradation of glucose, a combined chemical and enzymatic pre-treatment of Sorghum leads to the release of large amounts of this monosaccharide into the supernatant. This indicates that alkali pre-treatment does not lead to complete cellulose destruction. The high degradation of lignin structure in the first step of the pre-treatment rendered the remainder of the biomass available for enzymatic action. A comparison of the efficiency of biogas production from untreated Sorghum and Sorghum treated with the use of NaOH and enzymes shows that chemical hydrolysis improves the anaerobic digestion effectiveness and the combined pre-treatment could have great potential for methane generation.


2018 ◽  
Vol 78 (7) ◽  
pp. 1566-1575 ◽  
Author(s):  
S. S. Rathnaweera ◽  
B. Rusten ◽  
K. Korczyk ◽  
B. Helland ◽  
E. Rismyhr

Abstract A pilot-scale CFIC® (continuous flow intermittent cleaning) reactor was run in anoxic conditions to study denitrification of wastewater. The CFIC process has already proven its capabilities for biological oxygen demand removal with a small footprint, less energy consumption and low cost. The present study focused on the applicability for denitrification. Both pre-denitrification (pre-DN) and post-denitrification (post-DN) were tested. A mixture of primary treated wastewater and nitrified wastewater was used for pre-DN and nitrified wastewater with ethanol as a carbon source was used for post-DN. The pre-DN process was carbon limited and removal rates of only 0.16 to 0.74 g NOx-N/m²-d were obtained. With post-DN and an external carbon source, 0.68 to 2.2 g NO3-Neq/m²-d removal rates were obtained. The carrier bed functioned as a good filter for both the larger particles coming with influent water and the bio-solids produced in the reactor. Total suspended solids removal in the reactor varied from 20% to 78% (average 45%) during post-DN testing period and 9% to 70% (average 29%) for pre-DN. The results showed that the forward flow washing improves both the DN function and filtration ability of the reactor.


Author(s):  
Klaus Doelle ◽  
Qian Wang

The study tested a designed and built pilot scale packed bio-tower system under continuous operation using pre-clarified municipal wastewater. Performance was evaluated by measuring the removal of chemical oxygen demand and nitrogen ammonia. The pilot scale packed bio-tower system had a diameter of 1209 mm (4 ft.) and a height of 3,962 mm (13 ft.) and contained Bentwood CF-1900 bacteria growth media with a surface area of 6,028.80 ft² (560.09 m²). The municipal residential sewage was fed into a 1,481 l (375 gal.) recirculation reservoir at a temperature of 15°C (59.0°F) and a flow rate between 7,571 l/d (2000 gal/d) and 90,850 l/d (24,000 gal/d) and recirculated through the bio-tower with a fixed recirculation rate of 75.7 l/min (20 gal/min). The influent COD value reduction achieved is between 63.4% and 84.8%, whereas the COD influent value varied between 87 mg/l and 140 mg/l. The influent NH3-N reduction achieved was between 99.8% and 91.8% whereas the influent NH3-N value was between 28.8 mg/l and 18.6 mg/l  at a flow rate between 7571 l/d (2000 gal/d) and 90,850 l/d (24,000 gal/d).


2003 ◽  
Vol 47 (11) ◽  
pp. 153-156 ◽  
Author(s):  
J.-S. Kim ◽  
Y.-W. Hwang ◽  
C.-G. Kim ◽  
J.-H. Bae

This study was performed to develop a granular sulfur packed nitrification/denitrification process employing a uniquely designed single biofilter, which treated a relatively low carbon loaded domestic wastewater taken from a primary clarifier at a municipal wastewater treatment facility. The system was tested on varying experimental conditions, e.g. inflow flow, organic load and nitrogen load. Regardless of flow rate being increased, SS and COD was unvaryingly removed up to 90 and 80%, respectively. Moreover, TKN was also decomposed up to 90%. Increase in COD load gradually led to escalating level of non-biodegradable compounds observed in effluent. Nitrification was accomplished as high as 92%, whereas denitrification was achieved up to approximately 87%. For a while, nitrification and denitrification were observed at 0.65 and 0.55 kg/m3áday, respectively. Eventually, T-N was decomposed as high as 46%. It was concluded that granular sulfur can be used for not only electron donor, but also for a media to properly treat low carbon loaded wastewater and to filter SS efficiently.


2018 ◽  
Vol 78 (12) ◽  
pp. 2639-2646 ◽  
Author(s):  
Anita M. Rugaika ◽  
Damian Kajunguri ◽  
Rob Van Deun ◽  
Bart Van der Bruggen ◽  
Karoli N. Njau

Abstract Pilot-scale constructed wetlands (CWs) that allowed wastewater to flow with high interstitial velocities in a controlled environment were used to evaluate the possibility of using mass transfer approach to design horizontal subsurface flow constructed wetlands (HSSF-CWs) treating waste stabilisation ponds (WSPs) effluent. Since CW design considers temperature which is irrelevant in tropics, mass transfer approach could improve the design. HSSF-CWs were operated in batch recycle mode as continuous stirred tank reactors (CSTR) at different interstitial velocities. The overall removal rate constants of chemical oxygen demand (COD) at various interstitial velocities were evaluated in mesocosms that received pretreated domestic wastewater. The mean overall removal rate constants were 0.43, 0.69, 0.74 and 0.73 d−1 corresponding to interstitial velocities of 15.43, 36, 56.57 and 72 md−1, respectively. Results showed that the interstitial velocities up to 36 md−1 represented a range where mass transfer effect was significant and, above it, insignificant to the COD removal process. Since WSPs effluent has high flow rates and low organic load, it is possible to induce high interstitial velocities in a HSSF-CW treating this effluent, without clogging and overflow. The performance of these HSSF for tertiary treatment in tropical areas could be improved by considering flow velocity when designing.


Sign in / Sign up

Export Citation Format

Share Document