Automated determination and evaluation of water losses in water distribution systems

2015 ◽  
Vol 15 (6) ◽  
pp. 1414-1424
Author(s):  
Philipp Klingel ◽  
Axel Knobloch

Using conventional methods and tools for determining detailed zonal water balances and performance indicators involves considerable efforts in manual data collection and processing. Hence, water balances mostly are determined for a whole network only. Unmetered components are often neglected or based on rough estimates. This article presents an approach to the automated determination of zonal water balances and its implementation as a software tool. The approach is demonstrated for the practical case of the Pforzheim water utility (Stadtwerke Pforzheim GmbH & Co. KG).

2017 ◽  
Vol 18 (1) ◽  
pp. 347-356 ◽  
Author(s):  
Miran Mastaller ◽  
Philipp Klingel

Abstract Establishing the water balance developed by the International Water Association (IWA) is a worldwide applied approach to determine and analyse water losses in water distribution systems (WDS). The water balance covers those parts of a WDS within the responsibility of the water utility. Water losses occurring ‘before’ a customer meter are at the expense of the utility, while water lost or wasted ‘after’ the meter is paid for by the customer. This applies to systems where customer metering is in place and/or consumption is charged according to the consumed volumes. However, many WDS in the world lack customer meters, are operated intermittently and apply flat-rate tariffs. In intermittent supplies, a considerable amount of water is lost or wasted within the private properties. The flat-rate tariff might not cover this amount or part of the amount. Thus, actual consumption and wastage should be separately quantified with respect to the utility's water reduction measures. Accepting the described conditions, the authors have developed an adaption of the IWA water balance and the methods to establish the balance. In this paper the application of the developed approach in an initially unmetered WDS with intermittent water supply in the city of Tiruvannamalai, India, is presented.


2017 ◽  
Vol 7 (3) ◽  
pp. 396-406 ◽  
Author(s):  
Miran Mastaller ◽  
Philipp Klingel

The International Water Association water balance is an approach applied worldwide for determining and analysing water losses in water distribution systems (WDS) up to the point of customer metering. Thus, water losses occurring ‘before’ a customer meter are at the expenses of the water utility while water lost or wasted ‘after’ the meter is paid for by the customer. This applies to systems where customer metering is in place and/or consumption is charged according to the consumed volumes. However, many WDS in the world lack customer meters, are operated intermittently and a considerable amount of water is lost or wasted within the private property, e.g. by overflows of private tanks. The flat-rate tariff applied might not cover this amount or part of the amount. Thus, actual consumption and wastage should be separately quantified or estimated with respect to the utility's water reduction measures and the calculation of revenue water. This paper presents a water balance approach adapted to WDS which are operated intermittently, lack customer metering and charge flat-rate tariffs as well as a methodology for establishing the balance. The application is demonstrated for a district metered area of the city of Tiruvannamalai, India.


Water ◽  
2021 ◽  
Vol 13 (2) ◽  
pp. 131
Author(s):  
Jezabel D. Bianchotti ◽  
Melina Denardi ◽  
Mario Castro-Gama ◽  
Gabriel D. Puccini

Sectorization is an effective technique for reducing the complexities of analyzing and managing of water systems. The resulting sectors, called district metering areas (DMAs), are expected to meet some requirements and performance criteria such as minimum number of intervention, pressure uniformity, similarity of demands, water quality and number of districts. An efficient methodology to achieve all these requirements together and the proper choice of a criteria governing the sectorization is one of the open questions about optimal DMAs design. This question is addressed in this research by highlighting the advantages of three different criteria when applied to real-word water distribution networks (WDNs). To this, here it is presented a two-stage approach for optimal design of DMAs. The first stage, the clustering of the system, is based on a Louvain-type greedy algorithm for the generalized modularity maximization. The second stage, the physical dividing of the system, is stated as a two-objective optimization problem that utilises the SMOSA version of simulated annealing for multiobjective problems. One objective is the number of isolation valves whereas for the second objective three different performance indices (PIs) are analyzed and compared: (a) standard deviation, (b) Gini coefficient and (c) loss of resilience. The methodology is applied to two real case studies where the first two PIs are optimized to address similar demands among DMAs. The results demonstrate that the proposed method is effective for sectorization into independent DMAs with similar demands. Surprisingly, it found that for the real studied systems, loss of resilience achieves better performance for each district in terms of pressure uniformity and demand similarity than the other two specific performance criteria.


2021 ◽  
Author(s):  
KEZHEN RONG ◽  
Minglei Fu ◽  
JIAWEI CHEN ◽  
LEJIN ZHENG ◽  
JIANFENG ZHENG ◽  
...  

Abstract Water distribution systems (WDSs) are used to transmit and distribute water resources in cities. Water distribution networks (WDNs) are partitioned into district metered areas (DMAs) by water network partitioning (WNP), which can be used for leak control, pollution monitoring, and pressure optimization in WDS management. In order to overcome the limitations of optimal search range and the decrease of recovery ability caused by two-step WNP and fixed DMAs in previous studies, this study developed a new method combining a graph neural network to realize integrated WNP and dynamic DMAs to optimize WDS management and respond to emergencies. The proposed method was tested in a practical case study; the results showed that good hydraulic performance of the WDN was maintained and that dynamic DMAs demonstrated excellent stability in emergency situations, which proves the effectiveness of the method in WNP.


2012 ◽  
Vol 12 (5) ◽  
pp. 580-587 ◽  
Author(s):  
Stephen Mounce ◽  
John Machell ◽  
Joby Boxall

Safe, clean drinking water is a foundation of society and water quality monitoring can contribute to ensuring this. A case study application of the CANARY software to historic data from a UK drinking water distribution system is described. Sensitivity studies explored appropriate choice of algorithmic parameter settings for a baseline site, performance was evaluated with artificial events and the system then transferred to all sites. Results are presented for analysis of nine water quality sensors measuring six parameters and deployed in three connected district meter areas (DMAs), fed from a single water source (service reservoir), for a 1 year period and evaluated using comprehensive water utility records with 86% of event clusters successfully correlated to causes (spatially limited to DMA level). False negatives, defined by temporal clusters of water quality complaints in the pilot area not corresponding to detections, were only approximately 25%. It was demonstrated that the software could be configured and applied retrospectively (with potential for future near real time application) to detect various water quality event types (with a wider remit than contamination alone) for further interpretation.


Sign in / Sign up

Export Citation Format

Share Document