Evaluating effective volume and hydrodynamic behavior in a full-scale ozone contactor with computational fluid dynamics simulation

2004 ◽  
Vol 4 (5-6) ◽  
pp. 277-288
Author(s):  
T. Mizuno ◽  
N.-S. Park ◽  
H. Tsuno ◽  
T. Hidaka

An ozone reaction model combined with CFD (Computational Fluid Dynamics) technique was developed in this research. In the simulation of ozonation, hydrodynamic behavior caused by bubbling of ozone contacting-gas is important as well as reaction kinetics. CFD technique elucidated hydrodynamic behavior in the selected ozone contactor, which consisted of three main chambers. Back-mixing zone was found in each chamber. The higher velocities of water were observed in the second and third chambers than that in the first one. The flow of the opposite direction to the main flow was observed near the water surface. Based on the results of CFD simulation, each chamber was divided into small compartments, and hydrodynamic behavior and effective volume were discussed. Mass balance equations were also established in each compartment with reaction terms associated with DOC, odor compounds, bacteria, bromide ion and bromate ion. This reaction model was intended to predict dissolved ozone concentration, especially. We concluded that the model could predict favourably the mass balance of ozone, namely absorption efficiency of gaseous ozone, dissolved ozone concentration and ozone consumption. After establishing the model, we discussed the effects of hydrodynamic behavior on dissolved ozone concentration.

Author(s):  
Guangyao Wang ◽  
Ye Tian ◽  
Spyros A. Kinnas

This work focuses on the study of the flow around a rigid cylinder with both particle image velocimetry (PIV) experiment and computational fluid dynamics (CFD) simulation. PIV measurements of the flow field downstream of the cylinder are first presented. The boundary conditions for CFD simulations are measured in the PIV experiment. Then the PIV flow is compared with both Reynolds-averaged Navier–Stokes (RANS) two-dimensional (2D) and large eddy simulation (LES) three-dimensional (3D) simulations performed with ANSYS fluent. The velocity vector fields and time histories of velocity are analyzed. In addition, the time-averaged velocity profiles and Reynolds stresses are analyzed. It is found that, in general, LES (3D) gives a better prediction of flow characteristics than RANS (2D).


Author(s):  
H. Hayashi ◽  
T. Yamaguchi

The beating motion of the heart wall, to which the major coronary arteries are fixed, is interesting, due to its possible mechanical influence on the flow inside the artery, and hence its effect on atherogenesis [1–2]. In this study, we conducted a computational fluid dynamics (CFD) simulation using a simplified model of the right coronary artery, which deforms with heart contractions. The results are discussed with respect to the local hemodynamics characteristics, particularly the streamline pattern and the wall shear stress distribution.


Author(s):  
Gil Jun Lee ◽  
Jay Kim ◽  
Tod Steen

Squeeze film dampers (SFDs) are used in high-speed turbomachinery to provide external damping to the system. Computational fluid dynamics (CFD) simulation is a highly effective tool to predict the performance of SFDs and obtain design guidance. It is shown that a moving reference frame (MRF) can be adopted for CFD simulation, which saves computational time significantly. MRF-based CFD analysis is validated, then utilized to design oil plenums of SFDs. Effects of the piston ring clearances, the oil groove, and oil supply ports are studied based on CFD and theoretical solutions. It is shown that oil plenum geometries can significantly affect the performance of the SFD especially when the SFD has a small clearance. The equivalent clearance is proposed as a new concept that enables quick estimation of the effect of oil plenum geometries on the SFD performance. Some design practices that have been adopted in industry are revisited to check their validity. Based on simulation results, a set of general design guidelines is proposed.


2017 ◽  
Vol 27 (7) ◽  
pp. 969-982 ◽  
Author(s):  
Fu-Jiang Chen ◽  
Qin-Yu Wu ◽  
Dan-Dan Huang ◽  
Yun Zhang ◽  
Wang Lu ◽  
...  

The fabric air dispersion system (FADS) is a ventilation terminal made of special polymer fabric. The porous structure of the fabric causes complex flow motion. Due to its advantages over the conventional ventilation system, i.e. ducts and diffusers, the FADS has been widely favoured by architects and researchers. In computational fluid dynamics (CFD) simulation the FADS is usually simplified into a free opening with an area equal to all pores and perforations, called the free area (FA) method in this present work. However, the effectiveness of this simplified method has not been validated. The present work took a half cylindrical FADS without orifices as an example and employed the FA method to simulate the airflow properties inside a chamber under isothermal and non-isothermal conditions. The simulated distributions of air velocity and temperature were compared with those by the direct description (DD) method. Meanwhile, the uniformity of air velocity distribution close to the FADS was validated against test data and the flow visualization using the dry ice as a smoking material. Results demonstrate that the FA method is effective and easy to implement, and performs as well as the DD method in predicting the distribution of airflow generated by the FADS without orifices.


2021 ◽  
Author(s):  
Majid Bayatian ◽  
Khosro Ashrafi ◽  
Zahra Amiri ◽  
Elahe Jafari

Abstract Viruses can be transmitted in indoor environments. Important factors in Indoor Air Quality (IAQ) are air velocity, relative humidity, temperature, and airflow pattern and Computational fluid dynamics (CFD) can use for IAQ assessment. The objective of this study is to CFD simulation in the living room to the prediction of the air pattern and air velocity. A computational fluid dynamic model was applied for airflow pattern and air velocity simulation. For simulation, GAMBIT, FLUENT, and CFD post software were used as preprocessing, processing, and post-processing, respectively. CFD validation was carried out by comparing the computed data with the experimental measurements. The final mesh number was set to 1,416,884 elementary cells and SIMPLEC algorithm was used for pressure-velocity coupling. PERSTO, and QUIK schemes have been used for the pressure terms, and the other variables, respectively. Simulations were carried out in ACH equals 3, 6 and 8 in four lateral walls. The maximum error and root mean square error from the air velocity were 14% and 0.10, respectively. Terminal settling velocity and relaxation time were equal to 0.302 ×10− 2 m/s and 0.0308 ×10− 2 s for 10 µm diameter particles, respectively. The stopping distance was 0.0089m and 0.011m for breathing and talking, respectively. The maximum of mean air velocity is in scenario 4 with ACH = 8 that mean air velocity is equal to 0.31 in 1.1m height, respectively. The results of this study showed that avoiding family gatherings is necessary for exposure control and suitable airflow and pattern can be improving indoor air conditions.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yunduo Charles Zhao ◽  
Parham Vatankhah ◽  
Tiffany Goh ◽  
Rhys Michelis ◽  
Kiarash Kyanian ◽  
...  

AbstractDisturbed blood flow has been increasingly recognized for its critical role in platelet aggregation and thrombosis. Microfluidics with hump shaped contractions have been developed to mimic microvascular stenosis and recapitulate the prothrombotic effect of flow disturbance. However the physical determinants of microfluidic hemodynamics are not completely defined. Here, we report a refined computational fluid dynamics (CFD) simulation approach to map the shear rate (γ) and wall shear stress (τ) distribution in the stenotic region at high accuracy. Using ultra-fine meshing with sensitivity verification, our CFD results show that the stenosis level (S) is dominant over the bulk shear rate (γ0) and contraction angle (α) in determining γ and τ distribution at stenosis. In contrast, α plays a significant role in governing the shear rate gradient (γ′) distribution while it exhibits subtle effects on the peak γ. To investigate the viscosity effect, we employ a Generalized Power-Law model to simulate blood flow as a non-Newtonian fluid, showing negligible difference in the γ distribution when compared with Newtonian simulation with water medium. Together, our refined CFD method represents a comprehensive approach to examine microfluidic hemodynamics in three dimensions and guide microfabrication designs. Combining this with hematological experiments promises to advance understandings of the rheological effect in thrombosis and platelet mechanobiology.


Author(s):  
Yue-Lin Hsieh ◽  
Dan Wang ◽  
Xiaobing Xu ◽  
Dengtao Yu ◽  
Yongzhen Wu ◽  
...  

There has been a growing interest in the investigation of hydroacoustic characteristics of pulsatile tinnitus (PT). However, a proper technique for computational fluid dynamics (CFD) simulation has yet to be discussed. The primary goal of this paper was to investigate the intrasinus hydroacoustic characteristics of PT at the transverse-sigmoid junction (TSJ) using Doppler ultrasound and examine the validity of CFD techniques in simultaneity. The preoperative and intraoperative Doppler ultrasound were performed on a patient with PT at upper jugular vein and TSJ, respectively. Canonical CFD techniques were applied to solve the computational transverse-sigmoid sinus flow domain and compared with the Doppler’s measurements. In addition, the spectro-temporal analysis was performed for the sonification of PT. PT was associated with the recirculating flows at the TSJ according to ultrasonographic detection. This pathogenic region was characterized by a sudden deceleration of flow velocity and inverse increase of flow static pressure, which large eddy simulation (LES) resulted in the smallest 6% velocity difference compared to the measured Doppler data, albeit with little differences compared to other solvers. Therefore, based on this case study, the transient LES approach is an optimal CFD method for the computational simulation of the complex hemodynamics at the TSJ. Further numerical studies with large case series are warrranted.


2016 ◽  
Vol 13 (10) ◽  
pp. 7176-7183
Author(s):  
Tao Li ◽  
Gannan Yuan

High pressure waterjet drilling (HPWD) as a cutting-edge upstream technology receives considerable attention in horizontal drilling fields. HPWD technology achieves great commercial benefits for the reentry multilateral well drilling in small diameter space where the conventional rotary drill bit needs high-cost tools to implement. The sophisticated waterjet downhole drilling environments are difficult to predict because the temperatures and pressures varied with the depth of the well and the chemical compositions of drilling fluid. Different proportion of waterjet drilling fluid (density or viscosity) may produce different pressures and temperatures for the waterjet drilling bit. Therefore, computational fluid dynamics (CFD) simulation of the waterjet drilling environments is of crucial significance, especially for the design of downhole navigation apparatus. This paper describes the design details of helix drilling calibration (HIDC) apparatus with MEMS gyroscope based measurement while drilling (MGWD) device in downhole harsh conditions. The design objective of HIDC apparatus is that the determined errors of MGWD device interrupted by scale factor errors and axis non-orthogonal errors can be modulated and the stochastic errors and the bias drift of MGWD device can be reduced. The drilling environments of HIDC apparatus are simulated by ANSYS INFLUENT software and the simulation results demonstrate that the temperature, the pressure and the flow rate of waterjet drilling fluid to HIDC apparatus are 172.85 °C, 4×108 Pa and 704.4823 m/s respectively.


CrystEngComm ◽  
2018 ◽  
Vol 20 (41) ◽  
pp. 6546-6550 ◽  
Author(s):  
Yosuke Tsunooka ◽  
Nobuhiko Kokubo ◽  
Goki Hatasa ◽  
Shunta Harada ◽  
Miho Tagawa ◽  
...  

The combination of the CFD simulation and machine learning thus makes it possible to determine optimized parameters for high-quality and large-diameter crystals.


Author(s):  
Adnan Ghareeb Tuaamah Al-Hasnawi ◽  
H. A. Refaey ◽  
T. Redemann ◽  
M. Attalla ◽  
E. Specht

The mixing of the two axial flows through the ware and through the gap between ware and walls using side nozzles in the preheating zone of tunnel kiln is investigated. The three-dimensional temperature field in the cross section between the two cars is calculated using the computational fluid dynamics (CFD) tool fluent. The mixing quality is evaluated using contours, the frequency of temperature distribution, and the maximum temperature difference. The influence on the mixing behavior of injection flow rate, injection velocity, nozzles position, and nozzle number has been analyzed. The results show that using two nozzles is more effective than one nozzle if the nozzles are installed at the opposite side walls with high vertical distance. The mixing quality increases strongly until an impulse flow rate (IFR) of about 4 N. For higher values, the influence becomes relatively low. The results for the mixing temperature obtained through CFD simulation compared with analytical results show a good agreement with maximum error of 0.5%.


Sign in / Sign up

Export Citation Format

Share Document