Uncertainty in air stripping tower design: implications of the air-to-water ratio

2001 ◽  
Vol 1 (4) ◽  
pp. 177-184
Author(s):  
B.I. Dvorak ◽  
J.W. Schauble

Environmental engineers are frequently faced with uncertainty in making design decisions because the true value of many process parameters is unknown. In this study, the design of countercurrent air stripping towers was modeled using fuzzy numbers, taking into account uncertainties in mass transfer and Henry's constant. It was found that, in addition to cost, the risk of failure is an important design consideration for stripping tower design. A significant over-design is both cost-effective and results in less risk of design failure. The air-to-water ratio that yielded the least risk of failure switched from low to high as the removal efficiency of the tower increased. An important result is that at lower removal efficiencies, tower design and operation is most sensitive to uncertainties in mass transfer and at higher removal efficiencies, tower design and operation is most sensitive to uncertainties in Henry's constant . The implication is that low air-to-water ratios are best when the regulatory target removal efficiency is low and/or when the uncertainty in the value of the contaminant's Henry's constant is larger than the uncertainty in the mass transfer coefficient value. Otherwise a high air-to-water ratio results in the least risk of process failure.

2003 ◽  
Vol 47 (11) ◽  
pp. 189-194 ◽  
Author(s):  
Q.J. Yu ◽  
H. Xu ◽  
D. Yao ◽  
P. Williams

Biofilm (or attached growth) reactors can be effectively used to treat organic wastewater from various industries such as food processing industry. They have a number of advantages including high organic loading rates (OLRs) and improved operational stability. A flexible fibre biofim reactor (FFBR) has been developed for efficient and cost effective treatment of food processing wastewater. In the process, simple flexible fibre packing with a very high specific surface area is used as support for microorganisms. The COD removal efficiencies for a range of OLRs have been studied. The FFBR can support an increasingly high OLR, but with a corresponding decrease in the COD removal efficiency. Therefore, a two-stage FFBR was developed to increase the treatment efficiency for systems with high OLRs. Experimental results indicated that a high overall COD removal efficiency could be achieved. At an influent COD of about 2700 mg/L and an OLR of 7.7 kgCOD/m3d, COD removal efficiencies of 76% and 82% were achieved in the first and the second stage of the reactor, respectively. The overall COD removal efficiency was 96%. Therefore, even for wastewater samples with high organic strength, high quality treated effluents could be readily achieved by the use of multiple stage FFBRs.


2014 ◽  
Vol 926-930 ◽  
pp. 4209-4213
Author(s):  
An Feng Li ◽  
Yan Ying Ning ◽  
Wen Jiang Xu ◽  
Tao Pan

High concentrations of ammoniacal nitrogen in fecal sewage pose a great threat to subsequent treatment steps. The conventional removal technique in China mainly involves air stripping. However, the concentration of ammonia in the effluent is often very high, and the fillers in towers could exhibit scaling resulting in reduced lifetime in operation. Because of its high mass transfer characteristics, fluidized bed technology was used in our study of the air stripping method for improving the removal efficiency, using spherical biological ceramsites as the filler. The effects of temperature, pH, and fluidized bed residence time on the removal process were investigated. To compare the various effects of fluidized bed operation on nitrogen removal efficiency, traditional air stripping experiments were carried out using the identical gas flowrate, liquid flowrate, temperature and pH. The results show that the removal efficiency of ammoniacal nitrogen was improved using a fluidized bed. The mechanism of free ammonia mass transfer using fluidized bed technology was proposed. Finally, the filler adhesion problem was reduced and the technology was successfully applied to the air stripping of high concentration ammoniacal nitrogen from fecal sewage.


2009 ◽  
Vol 9 (4) ◽  
pp. 469-475
Author(s):  
T. Turtiainen

Radon is one of the contaminants that sometimes impair the water quality of wells, especially those drilled in bedrock. Domestic radon removal units based on aeration have been commercially available for more than ten years. In order to determine how effectively these units remove radon a new test protocol applying frequent sampling while letting 100 litres of water flow, was developed. This way, removal efficiencies can be more accurately calculated and possible malfunctions detected. Seven models of domestic aerators designed for removing radon from household water were tested. The aerators were based on diffused bubble aeration, spray aeration or jet aeration. The average removal efficiencies for 100 litres with a medium flow rate were 86–100% except for a unit that circulated the aerated water back to the well that had removal efficiency of 80% at the maximum. By conducting a questionnaire study usual problems related to the aeration units were localized and recommendations on maintenance and installation are given accordingly.


1995 ◽  
Vol 31 (12) ◽  
pp. 171-183 ◽  
Author(s):  
M. M. Saqqar ◽  
M. B. Pescod

The performance of the primary anaerobic pond at the Alsamra Wastewater Treatment Plant in Jordan was monitored over 48 months. Overall averages for the removal efficiencies of BOD5, COD and suspended solids were 53%, 53% and 74%, respectively. An improvement in removal efficiency with increase in pond water temperature was demonstrated. A model, which takes into account the variability of raw wastewater at different locations, has been developed to describe the performance of a primary anaerobic pond in terms of a settleability ratio for the raw wastewater. The model has been verified by illustrating the high correlation between actual and predicted pond performance.


1998 ◽  
Vol 38 (6) ◽  
pp. 287-294 ◽  
Author(s):  
Pen-C. Chiang ◽  
Chung-H. Hung ◽  
J. C. Mar ◽  
E. E. Chang

Both Henry's constants and volumetric mass transfer coefficients (KLa) of eight priority chlorinated organic compounds including 1,1-dichloroethene, methylene chloride, chloroform, carbon tetrachloride, 1,1,1-trichloroethane, trichloroethylene, tetrachloroethylene, and 1,4-dichlorobenzene in an air stripping packed column were investigated in this study. The liquid and gas phase EPICS (Equilibrium Partition in Closed System) and direct calculating methods were applied to determine the Henry's constants of VOCs. The interference of co-solute on Henry's constants was also investigated. Experimental results indicated that decrease in Henry's constants of VOCs was observed in the presence of humic acid but no apparent effect on Henry's constants was detected when there was NaCl and surfactant in solution. Four different configurations of packing media including Intalox Saddle, Super Intalox Saddle, Telleret, and Hedgehog made of polypropylene were respectively packed in the air stripping tower and investigated in the study. The dependence of hydraulic loading, air-water ratio, and configurations of packing media on mass transfer coefficients of VOCs was discussed.


2013 ◽  
Vol 14 (2) ◽  
pp. 304-311 ◽  
Author(s):  
Cameron Farrow ◽  
Edward McBean ◽  
Hamidreza Salsali

Ceramic water filters (CWFs) are utilized in many developing countries as point-of-use (POU) water treatment devices, to reduce waterborne pathogens in potable water. Virus removal efficiencies of several CWFs are investigated under various influent conditions using MS2 (ATCC: 15597-B1) as a surrogate phage for human enteric viruses. The addition of bentonite turbidity (6–8 NTU) in the influent source water showed increased viral removal efficiency of CWFs by 0.1–0.2 log compared to tests involving clear (<1 NTU) influents. Trials employing an applied clay cake layer, formed using highly turbid influent source water (100 NTU) and no cleaning regime between trials, resulted in viral removal efficiency values of 1.5–2.5 log, compared to 0.2–0.5 log during non-obstructed trials.


2004 ◽  
Vol 49 (5-6) ◽  
pp. 281-288 ◽  
Author(s):  
S.J. Kim ◽  
P.Y. Yang

A two-stage entrapped mixed microbial cell (2SEMMC) process which separates nitrification and denitrification phases by the installation of the anoxic and oxic EMMC reactors packed with EMMC carriers was operated with 6, 4, 3, and 2 hours of hydraulic retention time (HRT) using simulated domestic wastewater. The activated sludge was immobilized using cellulose acetate for the EMMC carriers. Similar soluble chemical oxygen demand (SCOD) removal efficiencies of 90-97% were observed for all HRTs (SCOD loading rate of 0.84-2.30 g/L/d) applied. In order to achieve more than 80 % of TN removal efficiency, the HRT should be maintained higher than 4 hours (less than 0.24 g/L/d of TN loading rate). Denitrification was a rate-limiting step which controlled overall TN removal efficiency at TN loading rate of 0.15-0.31 g/L/d although nitrification efficiencies achieved 97-99 %. The effluent TSS of less than 25 mg/L in the 2SEMMC process was maintained at the SCOD loading rate of less than 1.23 g/L/d with back-washing intervals of 5 and 10 days in the anoxic and oxic EMMC reactors, respectively. The minimum HRT of 4 hours is required for high removal efficiencies of organics (average 95.6 %) and nitrogen (average 80.5 %) in the 2SEMMC process with 3 times of recirculation ratio.


2021 ◽  
Vol 261 ◽  
pp. 04005
Author(s):  
Emmanuel Nkudede ◽  
Husseini Sulemana ◽  
Bo Zhang ◽  
Kaida Zhu ◽  
Shan Hu ◽  
...  

Owing to its widespread and persistent usage, methylene blue (MB) is an environmental substance, mostly found in the printing and dyeing industry that raises concerns in the environment recently by posing significant threat to human life and the ecosystem as a whole. Thus, there is the need to effectively manage and treat the wastewater from these industries before reaching to the available water sources. Ozonation treatment is very efficient in treating printing and dyeing wastewater (MB) and can be greatly improved by using micro-bubble technology. Microbubble dissolution is an effective way to improve the rate of ozone mass transfer. To discover these properties, a method was used to improve the mass transfer of ozone microbubbles, which was used to effectively treat simulated printing and dyeing wastewater. We investigated the effects of pH, water temperature, ozone flow, and other conditions on the dissolution and attenuation properties of ozone in methylene blue microbubble solutions. Treatment of simulated printing and dyeing wastewater (methylene blue) was investigated under various initial pH and ozone flow rates. A catalytic exhibition was performed towards the decolorization of methylene blue (MB) concentrations and the corresponding COD removal efficiency. Ozone depletion and pH levels played key roles in MB degradation. Under high pH level of 11.01, the rate of removal of COD was 93.5%. Ozone dosage also has direct effect on COD removal efficiency and decolorization. Higher ozone flow rates, 0.4 L/min and 0.5 L/min recorded more than 94% degradation of COD thus very effective and efficient. Also, ozone flow rates 0.3 L/min, 0.4 L/min and 0.5 L/min with initial pH, 7.03, 6.63 and 6.36 decreased to 3.43, 3.49 and 3.44 after reaction processes which clearly shows that with high ozone dosage, pH reduces considerably.


Processes ◽  
2020 ◽  
Vol 8 (6) ◽  
pp. 720 ◽  
Author(s):  
Jin-Pil Kim ◽  
Dal Rae Jin ◽  
Wonseok Lee ◽  
Minhee Chae ◽  
Junwon Park

In this study, livestock wastewater treatment plants in South Korea were monitored to determine the characteristics of influent and effluent wastewater, containing four types of veterinary antibiotics (sulfamethazine, sulfathiazole, chlortetracycline, oxytetracycline), and the removal efficiencies of different treatment processes. Chlortetracycline had the highest average influent concentration (483.7 μg/L), followed by sulfamethazine (251.2 μg/L), sulfathiazole (230.8 μg/L) and oxytetracycline (25.7 μg/L), at five livestock wastewater treatment plants. Sulfathiazole had the highest average effluent concentration (28.2 μg/L), followed by sulfamethazine (20.8 μg/L) and chlortetracycline (11.5 μg/L), while no oxytetracycline was detected. For veterinary antibiotics in the wastewater, a removal efficiency of at least 90% was observed with five types of treatment processes, including a bio-ceramic sequencing batch reactor, liquid-phase flotation, membrane bioreactor, bioreactor plus ultrafiltration (BIOSUF) and bio best bacillus systems. Moreover, this study evaluated the removal efficiency via laboratory-scale experiments on the conventional contaminants, such as organic matter, nitrogen, phosphorus and veterinary antibiotics. This was done using the hydraulic retention time (HRT), under three temporal conditions (14 h, 18 h, 27 h), using the anaerobic–anoxic–oxic (A2O) process, in an attempt to assess the combined livestock wastewater treatment process where the livestock wastewater is treated until certain levels of water quality are achieved, and then the effluent is discharged to nearby sewage treatment plants for further treatment. The removal efficiencies of veterinary antibiotics, especially oxytetracycline and chlortetracycline, were 86.5–88.8% and 87.9–90.8%, respectively, exhibiting no significant differences under various HRT conditions. The removal efficiency of sulfamethazine was at least 20% higher at HRT = 27 h than at HRT = 14 h, indicating that sulfamethazine was efficiently removed in the A2O process with increased HRT. This study is expected to promote a comprehensive understanding of the behavior and removal of veterinary antibiotics in the livestock wastewater treatment plants of South Korea.


Sign in / Sign up

Export Citation Format

Share Document