scholarly journals Thermodynamic analysis on an instantaneous water heating system of shower wastewater source heat pump

2017 ◽  
Vol 8 (3) ◽  
pp. 404-411 ◽  
Author(s):  
Yuguo Wu ◽  
Yake Jiang ◽  
Bo Gao ◽  
Zhigang Liu ◽  
Jing Liu

Abstract Water reuse and desalination systems are energy intensive processes, and their increasing use is leading energy consumption within water systems to be an increasingly important issue. Shower wastewater contains large amounts of heat, so there is an opportunity to recover energy from shower water to offset energy consumption elsewhere in water systems. This paper found ways to increase the output of hot water and lower the energy consumption by establishing a thermodynamic model of an instantaneous wastewater source heat pump. The system proved to be very effective, the heating COP (coefficient of performance) can reach 3.3 even in the winter. Under the conditions of limited heat transfer area, reducing the suction pressure of a compressor is a more feasible way to increase the hot water output to meet the needs of users rather than increasing the discharge pressure. Besides, increasing the heat transfer area of the evaporator is a more effective option. When the heat transfer area of evaporator varies from 0.5 to 1.0 square meters, a notable change is that the heating COP increases from 3.283 to 3.936. The heating COP in a system with a recuperator can reach 5.672, almost double that compared to the original systems.

2021 ◽  
Author(s):  
Afarin Amirirad

Considering the large energy consumption of conventional water heaters in residential buildings, the performance of a new type of water heater has been characterized through conducting experiments and numerical modelling. The specific water heater investigated in this work benefits from heat absorption from the indoor air, denoted as the air source heat pump water heater (ASHPWH), and is located in the Archetype Sustainable Twin House B in Toronto. The experiments have been conducted under three different indoor conditions associated with temperature and humidity. The coefficient of performance (COP), which quantifies the ratio of heating capacity to the consumed power of ASHPWH, ranges between 1.5 and 5, depending on the indoor dry bulb and water inlet temperatures. A TRNSYS model of ASHPWH has been constructed based on the obtained experimental results and has subsequently been integrated with a TRNSYS model of the Archetype Sustainable House (ASH). The numerical results were verified with the experimental data. The model results suggests that after employing ASHPWH, the domestic hot water energy consumption reduces by 60.3% and 53.2% compared to the electric water heater in summer and winter respectively. Due to the energy absorption of ASHPWH from the indoor environment, the heating load of the ASH house increases while its cooling load decreases. Furthermore, the annual electricity consumption of the ASH house due to the required heating and cooling as well as the domestic hot water demand is reduced by 21.3%. Finally, as a consequence of employing ASHPWH, the energy cost and GHG emission were reduced respectively by 22% and 21.7%. By investigating the system in four other Canadian cities, it appears that Vancouver and Edmonton would have the maximum and minimum energy savings respectively.


2021 ◽  
Author(s):  
Afarin Amirirad

Considering the large energy consumption of conventional water heaters in residential buildings, the performance of a new type of water heater has been characterized through conducting experiments and numerical modelling. The specific water heater investigated in this work benefits from heat absorption from the indoor air, denoted as the air source heat pump water heater (ASHPWH), and is located in the Archetype Sustainable Twin House B in Toronto. The experiments have been conducted under three different indoor conditions associated with temperature and humidity. The coefficient of performance (COP), which quantifies the ratio of heating capacity to the consumed power of ASHPWH, ranges between 1.5 and 5, depending on the indoor dry bulb and water inlet temperatures. A TRNSYS model of ASHPWH has been constructed based on the obtained experimental results and has subsequently been integrated with a TRNSYS model of the Archetype Sustainable House (ASH). The numerical results were verified with the experimental data. The model results suggests that after employing ASHPWH, the domestic hot water energy consumption reduces by 60.3% and 53.2% compared to the electric water heater in summer and winter respectively. Due to the energy absorption of ASHPWH from the indoor environment, the heating load of the ASH house increases while its cooling load decreases. Furthermore, the annual electricity consumption of the ASH house due to the required heating and cooling as well as the domestic hot water demand is reduced by 21.3%. Finally, as a consequence of employing ASHPWH, the energy cost and GHG emission were reduced respectively by 22% and 21.7%. By investigating the system in four other Canadian cities, it appears that Vancouver and Edmonton would have the maximum and minimum energy savings respectively.


Author(s):  
Michael J. Kazmierczak ◽  
Abhishek Gupta

Experiments were performed on a heat exchanger equipped with multiple thermoelectric (TE) modules. The TE-HX serves as the basic system component in a simple hydronic modular Peltier heat pump system designed to provide chilled or hot water for domestic use (or supplementary building climate control) of small residences [1]. The present work focuses on the detailed convection analysis inside the TE-HX component when 10 thermoelectric modules are utilized. The local heat transfer coefficient at different points along the channel are measured at steady-state, first, when a continuous heater is installed and then when replaced with 10 TE modules. The experimental heat transfer coefficients obtained are compared with available empirical correlations for “transition” (3000 < ReDh < 7000) turbulent flow inside the channel with fair-to-good results. Next, the resulting coefficient-of-performance of the TE heat pump system is measured with its value depending both on system input power and water flow rate. Testing showed that performance degradation, i.e. reduced COPs, occurred when operated at higher power levels but remains satisfactory for up to 688 Watts with higher flow rate.


2016 ◽  
Vol 19 ◽  
pp. 20-26 ◽  
Author(s):  
Moritz Hein ◽  
Ralf Stöber ◽  
Gerhard Fischerauer ◽  
Johannes Bürner ◽  
Jörg Franke ◽  
...  

The central heating units of buildings are typically replaced every 20 to 30 years. There exists a variety of solutions for fuel-and gas-based units, but it would be advantageous to be able to use renewable energies. This would become possible by the combination of planar carbon-fiber-based infrared (IR) radiant heating foils with a heat pump providing hot water. The main goal of our proposed overall control strategy is to increase the energy efficiency while maintaining the thermal comfort for the residents. We examined the electromagnetic compatibility of the heating foils and simulated the relative contributions of the amount of energy provided by the heat pump and by the heating foils to obtain a maximum coefficient of performance for the combined heating system.


2014 ◽  
Vol 529 ◽  
pp. 625-629
Author(s):  
Chao Yi Tan ◽  
Peng Fei Yang ◽  
Meng Meng Wang ◽  
Hai Hua Hu ◽  
Guo Qiang Zhang

In order to improve EER of the ground source heat pump system and reduce heat transfer area of the ground heat exchanger, the authors had developed a series connection ground source heat pump water chiller-heater unit, after theoretical analyses, proved that placing the water chilled in front of the hot water unit could acquire a higher EER comparing to the opposite. In the meantime, this unit had a higher EER than a common water chiller-heater unit or a water chiller-heater unit with condensing heat recovery device. In an air conditioning system of ground source heat pump, employing the above mentioned unit can also reduce heat transfer area of the ground heat exchanger. It suggested that series connection ground source heat pump water chiller-heater unit is a kind of technology with a great development potential.


2020 ◽  
Vol 12 (24) ◽  
pp. 10521
Author(s):  
Mariusz Szreder ◽  
Marek Miara

A standard Polish household with a central heating system powered by a solid fuel furnace was chosen as a case study. The modular Air Source Heat Pump (ASHP) was used to heat the hot water outside the heating season. In this article comparative studies of the impact of the compressor drive system used on the energy efficiency of the heat pump have been carried out in operating conditions. The ASHP heating capacity and coefficient of performance (COP) were determined for the outside air temperature in the range from 7 to 22 °C by heating the water in the tank to a temperature above 50 °C. For the case of a fixed speed compressor, average heating capacity in the range 2.7−3.1 kW and COP values in the range 3.2−4.6 depending on the evaporator supply air temperature were obtained. Similarly, for the inverter compressor, the average heating capacity in the range of 2.7−5.1 kW was obtained for the frequency in the range of 30–90 Hz and COP in the range 4.2−5.7, respectively. On cool days, the average heating capacity of the heat pump decreases by 12%. For the simultaneous operation of two compressors with comparable heating capacity, lower COP values were obtained by 20%.


Author(s):  
Lin Fu ◽  
Yan Li

This paper presents a new approach to utilize geothermal energy with absorption heat pump in district heating system. The heat pump is driven by the temperature-difference between primary and secondary heating loops. In this method, the low-grade thermal energy can be used in district heating system effectively, as a result, the heating capacity and energy efficiency of district heating system can be improved more than 20%. On one hand, it could relieve the existing dilemma (shortage) of central heat source, as well enhance the delivery capacity of heating network dramatically. On the other hand, heating cost may be reduced remarkably, due to the reduction in both coal consumption of central heat and energy consumption of delivery pump. Firstly, this paper introduces the district heating method based on distributed absorption heat pumps through the analysis on the parameter characteristics of low-grade energy, hot water of primary and secondary heating network, as well as the operation parameters of absorption heat pumps. Secondly, an economic and energy consumption analysis was discussed by comparing the new approach with conventional heating system. Finally, this paper presents several system configurations, discusses the operation strategies in various conditions, and proposes the operation modes for heating season.


HortScience ◽  
1994 ◽  
Vol 29 (4) ◽  
pp. 249a-249
Author(s):  
Eric A. Lavoie ◽  
Damien de Halleux ◽  
André Gosselin ◽  
Jean-Claude Dufour

The main objective of this research was to produce a simulated model that permitted the evaluation of operating costs of commercial greenhouse tomato growers with respect to heating methods (hot air, hot water, radiant and heat pumps) and the use of artificial lighting for 1991 and 1992. This research showed that the main factors that negatively influence profitability were energy consumption during cold periods and the price of tomatoes during the summer season. The conventional hot water system consumed less energy than the heat pump system and produced marketable fruit yields similar to those from the heat pump system. The hot water system was generally more profitable in regards to energy consumption and productivity. Moreover, investment costs were less; therefore, this system gives best overall financial savings. As for radiant and hot air systems, their overall financial status falls between that of the hot water system and the heat pump. The radiant system proved to be more energy efficient that the hot air system, but the latter produced a higher marketable fruit yield over the 2-year study.


Energies ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1576
Author(s):  
Piotr Jadwiszczak ◽  
Jakub Jurasz ◽  
Bartosz Kaźmierczak ◽  
Elżbieta Niemierka ◽  
Wandong Zheng

Heating and cooling sectors contribute to approximately 50% of energy consumption in the European Union. Considering the fact that heating is mostly based on fossil fuels, it is then evident that its decarbonization is one of the crucial tasks for achieving climate change prevention goals. At the same time, electricity sectors across the globe are undergoing a rapid transformation in order to accommodate the growing capacities of non-dispatchable solar and wind generators. One of the proposed solutions to achieve heating sector decarbonization and non-dispatchable generators power system integration is sector coupling, where heat pumps are perceived as a perfect fit. Air source heat pumps enable a rapid improvement in local air quality by replacing conventional heating sources, but at the same time, they put additional stress on the power system. The emissions associated with heat pump operation are a combination of power system energy mix, weather conditions and heat pump technology. Taking the above into consideration, this paper presents an approach to estimate which of the mentioned factors has the highest impact on heat pump emissions. Due to low air quality during the heating season, undergoing a power system transformation (with a relatively low share of renewables) in a case study located in Poland is considered. The results of the conducted analysis revealed that for a scenario where an air-to-water (A/W) heat pump is supposed to cover space and domestic hot water load, its CO2 emissions are shaped by country-specific energy mix (55.2%), heat pump technology (coefficient of performance) (33.9%) and, to a lesser extent, by changing climate (10.9%). The outcome of this paper can be used by policy makers in designing decarbonization strategies and funding distribution.