scholarly journals Optimized coupling of a submerged membrane electro-bioreactor with pre-anaerobic reactors containing anode electrodes for wastewater treatment and fouling reduction

2016 ◽  
Vol 7 (3) ◽  
pp. 353-364
Author(s):  
Nader Taghipour ◽  
Mohammad Mosaferi ◽  
Mohammad Shakerkhatibi ◽  
Neemat Jaafarzadeh ◽  
Reza Dehghanzadeh ◽  
...  

In this paper, the performance of a submerged membrane electro-bioreactor with pre-anaerobic reactors containing anode electrodes (SMEBR+) was compared with that of a membrane bioreactor (MBR) in municipal wastewater treatment. The new design idea of the SMEBR+ was based on applications of direct current (DC) on the anode and cathode electrodes. The pilot study was divided into 2 stages and operated for 48 days. In Stage I, the MBR was continuously operated for 24 days without the application of electrodes. In Stage II, the SMEBR+ was continuously operated for 24 days, while aluminum electrodes and an intermittent DC were working with an operational mode of 2 min ON/4 min OFF at a constant voltage of 1.4 V. The results indicated that membrane fouling was reduced by nearly 22.02% in the SMEBR+ compared to the MBR. The results also showed that the SMEBR+ increased the quality of effluent to the extent that high removals of NH3+-N, PO43−-P, and chemical oxygen demand (COD) were 98%, 76%, and 90%, respectively. This system, in comparison with those proposed in other studies, showed a suitable improvement in biological treatments, considering the high removal of NH3+-N. Therefore, SMEBR+ can be considered as a promising treatment alternative to the conventional MBR.

2011 ◽  
Vol 365 ◽  
pp. 354-360 ◽  
Author(s):  
Shuo Liu ◽  
Ji Fu Wang ◽  
Bao Zhen Wang ◽  
Bing Wang ◽  
Wei Wan

To solve the problem of eutrophication in receiving water, a novel Membrane Bioreactor (MBR) with combined configuration was designed for municipal wastewater treatment and reclamation. By dividing bioreactor into three zones, the combined MBR operated under anoxic, anaerobic and aerobic conditions. It provided optimum conditions for nitrification, denitrifying and phosphate accumulating bacterial growth which resulted in high biological nutrient removal rate directly. The operational performance of combined MBR pilot plant showed that it exhibited high nutrient removal rate on Chemical oxygen demand (CODcr), total nitrogen (TN) and total phosphorus (TP). The mean value of effluent CODcr, TN and TP removal rate was 90.63%, 63.05% and 60.51% respectively during 180 days of operation. In order to obtain stable membrane flux, the combined MBR packed with fibrous bio-film carrier and added diatomite. Furthermore, it could alleviate membrane fouling effectively. As a result, the combined MBR improved effluent water quality significantly and alleviated membrane fouling remarkably.


2021 ◽  
Author(s):  
Stavroula Kappa ◽  
Simos Malamis

In recent years, the research community has made constant efforts to develop new technologies for the recovery and valorization of water, nutrient and energy content of municipal wastewater. However, the recovery process is significantly limited due to the low-strength of sewage. Over the last 10 years, the Forward Osmosis (FO) process, has gained interest as a low-cost process with low membrane fouling propensity, which can convert municipal wastewater into a concentrated low-volume effluent, characterized by high organic and nutrient concentration. This chapter presents the main configurations that have been implemented for the concentration of municipal wastewater using FO, including their performance in terms of contaminant removal and water/reverse salt flux (Jw/Js). Furthermore, the draw solutions and respective concentrations that have been used in FO for the treatment of sewage are reported, while at the same time the positive and negative characteristics of each application are evaluated. Finally, in the last section of this chapter, the spontaneous FO followed by anaerobic process is integrated in a municipal wastewater treatment plant (WWTP) and compared with a conventional one. The comparison is done, in terms of the mass balance of the chemical oxygen demand (COD) and in terms of the energy efficiency.


Vestnik MGSU ◽  
2019 ◽  
pp. 589-602 ◽  
Author(s):  
Tran Ha Quan ◽  
Elena S. Gogina

Introduction. Vietnamese urban municipal wastewater treatment plants are mainly of aeration-type facilities. Nowadays, an aeration-type plant, the Sequencing Batch Reactor (SBR), is widely applied and possesses a number of advantages over traditional systems with suspended activated sludge. Advantages of the SBR are mainly concluded in simplicity of operation, occupied area and cost. There is a number of problems at the wastewater treatment plants; they are connected with supplying only a half of wastewater design amount for the treatment as well as with quality of the purified water that must satisfy requirements of the Vietnamese discharge standard, the Standard A. Therefore, reconstruction and modification of the SBR is the major challenger to ensure the sustained development of large Vietnamese cities and maintenance of ecological balance. Materials and methods. To enhance the efficiency of wastewater purification in the SBR, the experiments were set on reactor reconstruction and modification by two directions: (1) Technological method, i.e. applying the Biochip 25 biocarrier, and (2) Operation method, i.e. adding the anoxic phase in reactor operation cycle. Laboratory tests were conducted for each of the directions, including comparison of a typical reactor with the modified one. Results. The study resulted in obtaining an optimal amount of the BioChip biocarrier material (10 to 20 %) that increased efficiency of wastewater purification by 10 to 20 %. In addition to this, when creating an anoxic phase of the operation cycle, efficiency of nitrogen removal increased by 20 %. When the denitrification occurs under the anoxic conditions, it contributes to stabilization of ammonium nitrogen removal for daily nitrogen loading in reactor of 0.3 to 0.8 TKN kg/sludge kg. Conclusions. The suggested technology provides the quality of treated water corresponding with the Vietnamese Standard A requirements. At the present, it is planned to proceed with the experiment on the base of Vietnamese semi-industrial plant for research and appraisal of the SBR reconstruction and modification method. Acknowledgements. The authors are grateful to AKVA Control company in Samara for granted biocarrier Mutag BioChip 25 and to Associate Professor Tran Van Quang and his students, Nguyen Ngoc Phuong and Truong Quoc Dai, of Environment Protect Research Center, Danang University for support of the experiment.


Author(s):  
Klaus Doelle ◽  
Qian Wang

The study tested a designed and built pilot scale packed bio-tower system under continuous operation using pre-clarified municipal wastewater. Performance was evaluated by measuring the removal of chemical oxygen demand and nitrogen ammonia. The pilot scale packed bio-tower system had a diameter of 1209 mm (4 ft.) and a height of 3,962 mm (13 ft.) and contained Bentwood CF-1900 bacteria growth media with a surface area of 6,028.80 ft² (560.09 m²). The municipal residential sewage was fed into a 1,481 l (375 gal.) recirculation reservoir at a temperature of 15°C (59.0°F) and a flow rate between 7,571 l/d (2000 gal/d) and 90,850 l/d (24,000 gal/d) and recirculated through the bio-tower with a fixed recirculation rate of 75.7 l/min (20 gal/min). The influent COD value reduction achieved is between 63.4% and 84.8%, whereas the COD influent value varied between 87 mg/l and 140 mg/l. The influent NH3-N reduction achieved was between 99.8% and 91.8% whereas the influent NH3-N value was between 28.8 mg/l and 18.6 mg/l  at a flow rate between 7571 l/d (2000 gal/d) and 90,850 l/d (24,000 gal/d).


Membranes ◽  
2020 ◽  
Vol 10 (9) ◽  
pp. 231
Author(s):  
Yi Ding ◽  
Zhansheng Guo ◽  
Zhenlin Liang ◽  
Xuguang Hou ◽  
Zhipeng Li ◽  
...  

In this study, the characteristics of activated sludge flocs were investigated and their effects on the evolution of membrane fouling were considered in the anaerobic membrane bioreactors (AnMBR), which were operated at 25 and 35 °C for municipal wastewater treatment. It was found that the membrane fouling rate of the AnMBR at 25 °C was more severe than that at 35 °C. The membrane fouling trends were not consistent with the change in the concentration of soluble microbial product (SMP). The larger amount of SMP in the AnMBR at 35 °C did not induce more severe membrane fouling than that in the AnMBR at 25 °C. However, the polysaccharide and protein concentration of extracellular polymeric substance (EPS) was higher in the AnMBR at 25 °C in comparison with that in the AnMBR at 35 °C, and the protein/polysaccharide ratio of the EPS in the AnMBR at 25 °C was higher in contrast to that in the AnMBR at 35 °C. Meanwhile, the fouling tendencies measured for the AnMBRs could be related to the characteristics of loosely bound EPS and tightly bound EPS. The analysis of the activated sludge flocs characteristics indicated that a smaller sludge particle size and more fine flocs were observed at the AnMBR with 25 °C. Therefore, the membrane fouling potential in the AnMBR could be explained by the characteristics of activated sludge flocs.


2020 ◽  
Vol 15 (2) ◽  
pp. 515-527
Author(s):  
L. Desa ◽  
P. Kängsepp ◽  
L. Quadri ◽  
G. Bellotti ◽  
K. Sørensen ◽  
...  

Abstract Many wastewater treatment plants (WWTP) in touristic areas struggle to achieve the effluent requirements due to seasonal variations in population. In alpine areas, the climate also determines a low wastewater temperature, which implies long sludge retention time (SRT) needed for the growth of nitrifying biomass in conventional activated sludge (CAS). Moreover, combined sewers generate high flow and dilution. The present study shows how the treatment efficiency of an existing CAS plant with tertiary treatment can be upgraded by adding a compact line in parallel, consisting of a Moving Bed Biofilm Reactor (MBBR)-coagulation-flocculation-disc filtration. This allows the treatment of influent variations in the MBBR and a constant flow supply to the activated sludge. The performance of the new 2-step process was comparable to that of the improved existing one. Regardless significant variations in flow (10,000–25,000 m3/d) and total suspended solids (TSS) (50–300 mg/L after primary treatment) the effluent quality fulfilled the discharge requirements. Based on yearly average effluent data, TSS were 11 mg/L, chemical oxygen demand (COD) 27 mg/L and total phosphorus (TP) 0.8 mg/L. After the upgrade, ammonium nitrogen (NH4-N) dropped from 4.9 mg/L to 1.3 mg/L and the chemical consumption for phosphorus removal was reduced.


2018 ◽  
Vol 77 (9) ◽  
pp. 2242-2252 ◽  
Author(s):  
M. Vaccari ◽  
P. Foladori ◽  
S. Nembrini ◽  
F. Vitali

Abstract One of the largest surveys in Europe about energy consumption in Italian wastewater treatment plants (WWTPs) is presented, based on 241 WWTPs and a total population equivalent (PE) of more than 9,000,000 PE. The study contributes towards standardised resilient data and benchmarking and to identify potentials for energy savings. In the energy benchmark, three indicators were used: specific energy consumption expressed per population equivalents (kWh PE−1 year−1), per cubic meter (kWh/m3), and per unit of chemical oxygen demand (COD) removed (kWh/kgCOD). The indicator kWh/m3, even though widely applied, resulted in a biased benchmark, because highly influenced by stormwater and infiltrations. Plants with combined networks (often used in Europe) showed an apparent better energy performance. Conversely, the indicator kWh PE−1 year−1 resulted in a more meaningful definition of a benchmark. High energy efficiency was associated with: (i) large capacity of the plant, (ii) higher COD concentration in wastewater, (iii) separate sewer systems, (iv) capacity utilisation over 80%, and (v) high organic loads, but without overloading. The 25th percentile was proposed as a benchmark for four size classes: 23 kWh PE−1 y−1 for large plants > 100,000 PE; 42 kWh PE−1 y−1 for capacity 10,000 < PE < 100,000, 48 kWh PE−1 y−1 for capacity 2,000 < PE < 10,000 and 76 kWh PE−1 y−1 for small plants < 2,000 PE.


2013 ◽  
Vol 20 (1) ◽  
pp. 199-208 ◽  
Author(s):  
Marketa Julinova ◽  
Jan Kupec ◽  
Roman Slavik ◽  
Maria Vaskova

Abstract A synthetic polymer, polyvinylpyrrolidone (PVP - E 1201) primarily finds applications in the pharmaceutical and food industries due to its resistance and zero toxicity to organisms. After ingestion, the substance passes through the organism unchanged. Consequently, it enters the systems of municipal wastewater treatment plants (WWTP) without decomposing biologically during the waste treatment process, nor does it attach (through sorption) to particles of activated sludge to any significant extent, therefore, it passes through the system of a WWTP, which may cause the substance to accumulate in the natural environment. For this reason the paper investigates the potential to initiate aerobic biodegradation of PVP in the presence of activated sludge from a municipal wastewater treatment plant. The following agents were selected as the initiators of the biodegradation process - co-substrates: acrylamide, N-acethylphenylalanine and 1-methyl-2-pyrrolidone, a substance with a similar structure to PVP monomer. The biodegradability of PVP in the presence of co-substrates was evaluated on the basis of biological oxygen demand (BOD) as determined via a MicroOxymax O2/CO2/CH4 respirometer. The total substrate concentration in the suspension equaled 400 mg·dm-3, with the ratio between PVP and the cosubstrate being 1:1, while the concentration of the dry activated sludge was 500 mg·dm-3. Even though there was no occurrence of a significant increase in the biodegradation of PVP alone in the presence of a co-substrate, acrylamide appeared to be the most effective type of co-substrate. Nevertheless, a recorded decrease in the slope of biodegradation curves over time may indicate that a process of primary decomposition was underway, which involves the production of metabolites that inhibit activated sludge microorganisms. The resulting products are not identified at this stage of experimentation.


Sign in / Sign up

Export Citation Format

Share Document