scholarly journals Investigation of full-scale step-fed SBR under low dissolved oxygen: performance and microbial community response

2016 ◽  
Vol 51 (2) ◽  
pp. 141-152
Author(s):  
Heloísa Fernandes ◽  
Regina Vasconcellos Antonio ◽  
Rejane Helena Ribeiro da Costa

A decentralized full-scale sequencing batch reactor (SBR) system for treating wastewater was operated to assess their feasibility and the response of bacterial population dynamic and nutrient removal performance. The reactor was operated under low dissolved oxygen (DO) concentration (0.3–0.7 mgL−1) and an average applied organic load of 0.5 g COD L−1 d−1 (COD: chemical oxygen demand). Removal efficiencies were higher than 70% for both soluble chemical oxygen demand and ammonium, with average effluent concentration of 51 ± 15 mg COD L−1 and 16.0 mg NH4+ L−1. The mixed liquor volatile suspended solids/total suspended solids ratio was 0.9, and the average food/microorganism ratio was 0.3 g COD g VSS−1 d−1 (VSS: volatile suspended solids). The active biomass was composed of 94.9% heterotrophic and 5.1% autotrophic organisms. The most frequently identified were chemoorganoheterotrophic organisms affiliated with Bacteroidetes and Firmicutes, some of them with the capacity to denitrify and grow under low DO concentration. Temperature and sludge withdrawal were important factors in determining nitrification and phosphorus removal rates. The SBR was viable for domestic wastewater treatment and showed that the microbial community greatly influenced its performance. This work can also provide valuable insights into further applications in systems operated under low DO condition.

2021 ◽  
Author(s):  
◽  
Thandeka Yvonne Sthembile Jwara

Wastewater treatment is a critical chain in the urban water cycle. Wastewater treatment prevents the toxic contamination of water bodies. The notable consequences of contamination are the loss of aquatic life, upsurge of eutrophication due to nutrient overload, and potential loss of human life as a result of waterborne diseases. Wastewater works (WWW) are therefore an intrinsic component of protecting the urban water cycle and ensuring that water resources are preserved for future generations. The operation of a WWW is subject to compliance with the national legislative requirements imposed by the Department of Water and Sanitation (DWS) to ensure the preservation of water resources. These requirements oblige water and sanitation departments to employ innovative design, control and optimization of WWW. Wastewater modelling packages have presented the opportunity to simulate the wastewater treatment processes in order to maintain and sustain legal compliance with the DWS. The successful implementation of a simulation package for wastewater process optimization and modelling depends on an accurate characterization also known as fractionation of the organic fractions of the WWW influents. This thesis is a result of a comprehensive study reported for Darvill wastewater work. Darvill WWW is a 60 ML/D plant which has been receiving flows of up to 120 ML/D. The importance of the study was to motivate for the upgrade of the wastewater work to account for the increased hydraulic, organic and nutrient loading into the plant. The study looked at the application of the World Engine for Simulation and Training (WEST) and all studies required to generate data that will serve as input with the understanding the current state of Darvill WWW in terms of performance. The study presents the fractionation outcomes of the primary wastewater effluent organic matter as chemical oxygen demand (COD) and the performance by assessing the biological nutrient removal process (BNR) using BNR efficiencies in addition to the development of the Darvill WWW WEST model with the aid of the probabilistic fractionator. The fractionation was achieved through the oxygen uptake rate experiments using the respirometry method. Experiments yielded the following results: biodegradable COD (bCOD) (70.5%) and inert COD (iCOD) (29.5%) of the total COD. Further characterization of the bCOD and iCOD yielded the readily biodegradable fraction (SS) at 75%, slowly degradable (XS) at 25%, particulate inert (XI) was 50.8% and the inert soluble SI at 49.2%. The COD fractions were used and served as input to the development and evaluation of the Darvill WEST model. Calculations of BNR efficiencies were used to evaluate the effects of high inflow to the biological treatability of the activated sludge for the period September 2016 - November 2017. It was found that at inflows above design capacity, the nutrient removal efficiency reduced from an expected 80-90% to an average of 40% with an average soluble reactive phosphorus (SRP) removal efficiency being 64%. A data input file for the period of January – June 2016 was created to serve as input into WEST to develop a baseline average model for the Darvill WWW plant. The model results predicted a mixed liquor suspended solids (MLSS) concentration of 6475 mg/L for the plant during the study period this was comparable with the plant MLSS concentration of 6700 mg/L at the time which was above the design concentration of 4500 mg/L. This was largely due to the plant operating under nutrient overload conditions. The final effluent (FE) concentration in the defractionation model was found to be COD = 41.28 mg/L, ammonia (NH3) = 22.02 mg/L, Total Suspended Solids (TSS) = 32 mg/L, SRP = 2.16 mg/L. Most of these results were expectedly non-compliant to the discharge limits imposed by the DWS with the exception of COD. The plant FE measurements were COD = 45.1 mg/L, NH3 = 3.4 mg/L, TSS = 20.9 mg/L, SRP= 6.67 mg/L. The COD and TSS prediction were comparable to the model prediction however there were limitations in the models ability to predict NH3 and SRP. The model does not account for changes in dissolved oxygen (DO) and temperature as these parameters are kept constant for the purpose of this study. The model assumes a temperature of 20 oC and a DO concentration of 2 mg/L for the aerobic reactor, 0.01 mg/L for the anaerobic reactor and 0.1 mg/L for the anoxic reactor. The model assumes that with the nutrient overload, oxygen compensation occurs within the reactor to maintain a constant DO concentration within the units. This limits the model in the prediction of actual instance where the overload would deplete the DO and where other competing reactions would give rise to greater non-compliances as well as biological growth’s impairment due to cold weather conditions.


2015 ◽  
Vol 41 (1) ◽  
pp. 13-19
Author(s):  
Kaniz Fatema ◽  
Wan Maznah Wan Omar ◽  
Mansor Mat Isa

Water quality in three different stations of Merbok estuary was investigated limnologically from October, 2010 to September, 2011. Water temperature, transparency and total suspended solids (TSS) varied from 27.45 - 30.450C, 7.5 - 120 cm and 10 -140 mg/l, respectively. Dissolved Oxygen (DO) concentration ranged from 1.22-10.8 mg/l, while salinity ranged from 3.5-35.00 ppt. pH and conductivity ranged from 6.35 - 8.25 and 40 - 380 ?S/cm, respectively. Kruskal Wallis H test shows that water quality parameters were significantly different among the sampling months and stations (p<0.05). This study revealed that DO, salinity, conductivity and transparency were higher in wet season and TSS was higher in dry season. On the other hand, temperature and pH did not follow any seasonal trends.Bangladesh J. Zool. 41(1): 13-19, 2013


2012 ◽  
Vol 7 (1) ◽  
Author(s):  
S. S. Fatima ◽  
S. Jamal Khan

In this study, the performance of wastewater treatment plant located at sector I-9 Islamabad, Pakistan, was evaluated. This full scale domestic wastewater treatment plant is based on conventional activated sludge process. The parameters which were monitored regularly included total suspended solids (TSS), mixed liquor suspended solids (MLSS), mixed liquor volatile suspended solids (MLVSS), biological oxygen demand (BOD), and chemical oxygen demand (COD). It was found that the biological degradation efficiency of the plant was below the desired levels in terms of COD and BOD. Also the plant operators were not maintaining consistent sludge retention time (SRT). Abrupt discharge of MLSS through the Surplus Activated sludge (SAS) pump was the main reason for the low MLSS in the aeration tank and consequently low treatment performance. In this study the SRT was optimized based on desired MLSS concentration between 3,000–3,500 mg/L and required performance in terms of BOD, COD and TSS. This study revealed that SRT is a very important operational parameter and its knowledge and correct implementation by the plant operators should be mandatory.


Jurnal Ecolab ◽  
2021 ◽  
Vol 15 (2) ◽  
pp. 101-109
Author(s):  
Dewi Ratnaningsih ◽  
◽  
Retno Puji Lestari ◽  
Ernawita Nazir

Kualitas air di suatu wilayah yang merupakan salah satu indikator lingkungan dapat dievaluasi menggunakan parameter fisika, kimia, dan biologi. Indeks Kualitas Air Indonesia (IKA-INA) dapat digunakan untuk menilai kondisi kualitas air secara menyeluruh pada lokasi dan waktu tertentu. IKA-INA dihitung dengan menggunakan sepuluh (10) parameter yaitu pH, Total Dissolved Solid (TDS), Total Suspended Solid (TSS), Dissolved Oxygen (DO), Biological Oxygen Demand (BOD), Chemical Oxygen Demand (COD), NO3, NH3, Total Phosphate (TP) dan fecal coliform. IKA-INA tersebut merupakan indeks kualitas air yang dapat memberikan informasi secara sederhana. Dalam pemanfaatannya, tidak semua data parameter dalam IKA-INA tersebut dapat terpenuhi karena adanya data tidak valid atau data yang hilang. Kajian ini bertujuan untuk memberi alternatif rumusan IKA-INA dengan parameter yang tidak lengkap atau jika tidak semua data dalam parameters tersebut tersedia. Metode yang digunakan dalam menyusun rumusan adalah dengan melakukan koreksi faktor bobot parameter IKA-INA terhadap parameter yang hilang dan nilai Q (nilai sub-indeks). Setelah itu dilakukan uji coba pada nilai baku mutu air dalam Peraturan Pemerintah No. 22/2021 Lampiran VI serta pada data kualitas air sungai yang mewakili kualitas baik dan buruk. Hasil uji coba menunjukkan bahwa bobot parameter terkoreksi dapat digunakan untuk penanganan parameter yang hilang dalam penilaian kualitas air dengan metode IKA-INA. Hasil IKA-INA dengan parameter hilang yang menggunakan bobot terkoreksi dan hasil IKA-INA dengan parameter lengkap mayoritas memberikan status IKA yang tidak berbeda, kecuali untuk parameter fecal coli dan parameter yang mempunyai kadar jauh berbeda terhadap kondisi air secara keseluruhan.


Author(s):  
H. Garba ◽  
C. A. Elanu

An assessment of the chemical characteristics of industrial and domestic wastewater discharges on seven parameters into Kaduna River on a bimonthly basis was carried out. PH, dissolved oxygen (DO), chloride, nitrite, chemical oxygen demand (COD), biochemical oxygen demand (BOD) and iron were analyzed to determine their concentration levels. From the analysis, the highest mean concentration of the parameters were 8.24 of pH, 7.7 mg/l of DO, 233.4 mg/l of chloride, 55.68 mg/l of COD, 27.95 mg/l of nitrite, 122.22 mg/l of BOD, and 17.05 mg/l of iron. After comparing with prescribed standards, it can be concluded that there is evidence of organic and inorganic accumulation of contaminants into River Kaduna.


2020 ◽  
Vol 9 (6) ◽  
pp. e183963748
Author(s):  
Rafael Souza Leopoldino Nascimento ◽  
Ludymyla Marcelle Lima Silva ◽  
Lucas Periard ◽  
Anibal da Fonseca Santiago

The technology of microalgae photobioreactors and illuminated by LEDs has been widely studied for the treatment of wastewater. However, sunlight is a free resource and should be taken advantage of. But the question remains whether photobioreactors illuminated by natural (sunlight) light in combination with artificial light can have greater operational stability or greater performance when compared to systems illuminated only by artificial light. In this context, continuous flow photobioreactors illuminated by Light Emitting Diodes (LEDs) combined, or not, with sunlight were operated and had their performance evaluated. The variables analyzed were pH, OD, chemical oxygen demand (COD), chlorophyll - a and total suspended solids. The photobioreactors were effective for removing organic matter, with 75 ± 15% in the photobioreactor illuminated by LED and 65 ± 10% in the photobioreactor illuminated by sunlight and LED. The results showed that the use of combined lighting favors the production of dissolved oxygen and ensures greater operational stability in the removal of carbonaceous organic matter.


Materials ◽  
2019 ◽  
Vol 12 (22) ◽  
pp. 3784 ◽  
Author(s):  
Violetta Kozik ◽  
Krzysztof Barbusinski ◽  
Maciej Thomas ◽  
Agnieszka Sroda ◽  
Josef Jampilek ◽  
...  

The potential implementation of Envifer®, a commercial product containing potassium ferrate (40.1% K2FeO4), for the purification of highly contaminated tannery wastewater from leather dyeing processes was proposed. The employment of the Taguchi method for optimization of experiments allowed the discoloration (98.4%), chemical oxygen demand (77.2%), total organic carbon (75.7%), and suspended solids (96.9%) values to be lowered using 1.200 g/L K2FeO4 at pH 3 within 9 min. The application of the central composite design (CCD) and the response surface methodology (RSM) with the use of 1.400 g/L K2FeO4 at pH 4.5 diminished the discoloration, the chemical oxygen demand, the total organic carbon, and suspended solids within 9 min. The Taguchi method is suitable for the initial implementation, while the RSM is superior for the extended optimization of wastewater treatment processes.


Sign in / Sign up

Export Citation Format

Share Document