scholarly journals Biofoam formation and defoamation in global wastewater treatment systems

Author(s):  
Cynthia Dlangamandla ◽  
Moses Basitere ◽  
Benjamin Ifeoluwa Okeleye ◽  
Boredi Silas Chidi ◽  
Seteno Karabo Obed Ntwampe

Abstract Municipal wastewater treatment is largely based on activated sludge (AS) systems due to their ability to reduce biological and chemical oxygen demand (BOD/COD). They are similarly efficient in nitrification and denitrification. However, major drawbacks such as foaming associated with the prevalence of lipids (fats, oil, grease (FOG)) and proteinaceous material arise, which reduces AS efficiency – a focus of this review. Many strategies are employed for foam reduction in AS systems, where proliferation of foam-forming microorganisms can be challenging. To understand foam formation, prevention and deterioration, including destabilization, a multidisciplinary mitigation approach is required, in which some bioprocess aspects such as foam destabilization kinetics should be understood and quantified. This review reports on biological foam formation and source in wastewater treatment, defoaming strategies, and biofoam destabilisation kinetics as well as factors affecting foam stability.

2013 ◽  
Vol 67 (9) ◽  
pp. 1923-1933 ◽  
Author(s):  
Yoshiaki Tsuzuki ◽  
Thammarat Koottatep ◽  
Thitiphon Sinsupan ◽  
Supattra Jiawkok ◽  
Chira Wongburana ◽  
...  

The concept of pollution load indicators for planning and management of the mixture conditions of centralised and on-site wastewater treatment systems has not been discussed in detail so far. In this paper, pollutant discharge (load) indicators and pollutant removal efficiencies were quantitatively analysed to develop a part of a strategy for planning and management of municipal wastewater treatment systems (WWTSs) under the mixture conditions in Bangkok, Thailand, as a case study. Pollutant discharge indicators of on-site WWTSs were estimated based on the relevant literature. Three kinds of pollutant removal efficiency function at centralised wastewater treatment plants (CWWTPs) were empirically developed for biological oxygen demand, chemical oxygen demand, total nitrogen, total phosphorus, total coliforms and faecal coliforms based on the existing CWWTP management data. These results will be integrated into the scenario-based analysis in the second paper in the series. The results will be base datasets, and the concept and estimation methods can be applied for wastewater treatment planning and management in other areas.


Author(s):  
Klaus Doelle ◽  
Qian Wang

The study tested a designed and built pilot scale packed bio-tower system under continuous operation using pre-clarified municipal wastewater. Performance was evaluated by measuring the removal of chemical oxygen demand and nitrogen ammonia. The pilot scale packed bio-tower system had a diameter of 1209 mm (4 ft.) and a height of 3,962 mm (13 ft.) and contained Bentwood CF-1900 bacteria growth media with a surface area of 6,028.80 ft² (560.09 m²). The municipal residential sewage was fed into a 1,481 l (375 gal.) recirculation reservoir at a temperature of 15°C (59.0°F) and a flow rate between 7,571 l/d (2000 gal/d) and 90,850 l/d (24,000 gal/d) and recirculated through the bio-tower with a fixed recirculation rate of 75.7 l/min (20 gal/min). The influent COD value reduction achieved is between 63.4% and 84.8%, whereas the COD influent value varied between 87 mg/l and 140 mg/l. The influent NH3-N reduction achieved was between 99.8% and 91.8% whereas the influent NH3-N value was between 28.8 mg/l and 18.6 mg/l  at a flow rate between 7571 l/d (2000 gal/d) and 90,850 l/d (24,000 gal/d).


1991 ◽  
Vol 23 (10-12) ◽  
pp. 1723-1732 ◽  
Author(s):  
T. Matsui ◽  
S. Kyosai ◽  
M. Takahashi

Application of biotechnology to wastewater treatment for its improvement and greater understanding was investigated in the Japanese national project named Biofocus WT as to a microorganism bank, genetic engineering application, immobilization of microorganisms, bioreactors for wastewater treatment, bioreactors for sludge treatment, SS separators for raw wastewater, biosensors and new wastewater treatment systems.


2020 ◽  
Vol 15 (2) ◽  
pp. 515-527
Author(s):  
L. Desa ◽  
P. Kängsepp ◽  
L. Quadri ◽  
G. Bellotti ◽  
K. Sørensen ◽  
...  

Abstract Many wastewater treatment plants (WWTP) in touristic areas struggle to achieve the effluent requirements due to seasonal variations in population. In alpine areas, the climate also determines a low wastewater temperature, which implies long sludge retention time (SRT) needed for the growth of nitrifying biomass in conventional activated sludge (CAS). Moreover, combined sewers generate high flow and dilution. The present study shows how the treatment efficiency of an existing CAS plant with tertiary treatment can be upgraded by adding a compact line in parallel, consisting of a Moving Bed Biofilm Reactor (MBBR)-coagulation-flocculation-disc filtration. This allows the treatment of influent variations in the MBBR and a constant flow supply to the activated sludge. The performance of the new 2-step process was comparable to that of the improved existing one. Regardless significant variations in flow (10,000–25,000 m3/d) and total suspended solids (TSS) (50–300 mg/L after primary treatment) the effluent quality fulfilled the discharge requirements. Based on yearly average effluent data, TSS were 11 mg/L, chemical oxygen demand (COD) 27 mg/L and total phosphorus (TP) 0.8 mg/L. After the upgrade, ammonium nitrogen (NH4-N) dropped from 4.9 mg/L to 1.3 mg/L and the chemical consumption for phosphorus removal was reduced.


2018 ◽  
Vol 77 (9) ◽  
pp. 2242-2252 ◽  
Author(s):  
M. Vaccari ◽  
P. Foladori ◽  
S. Nembrini ◽  
F. Vitali

Abstract One of the largest surveys in Europe about energy consumption in Italian wastewater treatment plants (WWTPs) is presented, based on 241 WWTPs and a total population equivalent (PE) of more than 9,000,000 PE. The study contributes towards standardised resilient data and benchmarking and to identify potentials for energy savings. In the energy benchmark, three indicators were used: specific energy consumption expressed per population equivalents (kWh PE−1 year−1), per cubic meter (kWh/m3), and per unit of chemical oxygen demand (COD) removed (kWh/kgCOD). The indicator kWh/m3, even though widely applied, resulted in a biased benchmark, because highly influenced by stormwater and infiltrations. Plants with combined networks (often used in Europe) showed an apparent better energy performance. Conversely, the indicator kWh PE−1 year−1 resulted in a more meaningful definition of a benchmark. High energy efficiency was associated with: (i) large capacity of the plant, (ii) higher COD concentration in wastewater, (iii) separate sewer systems, (iv) capacity utilisation over 80%, and (v) high organic loads, but without overloading. The 25th percentile was proposed as a benchmark for four size classes: 23 kWh PE−1 y−1 for large plants > 100,000 PE; 42 kWh PE−1 y−1 for capacity 10,000 < PE < 100,000, 48 kWh PE−1 y−1 for capacity 2,000 < PE < 10,000 and 76 kWh PE−1 y−1 for small plants < 2,000 PE.


2013 ◽  
Vol 20 (1) ◽  
pp. 199-208 ◽  
Author(s):  
Marketa Julinova ◽  
Jan Kupec ◽  
Roman Slavik ◽  
Maria Vaskova

Abstract A synthetic polymer, polyvinylpyrrolidone (PVP - E 1201) primarily finds applications in the pharmaceutical and food industries due to its resistance and zero toxicity to organisms. After ingestion, the substance passes through the organism unchanged. Consequently, it enters the systems of municipal wastewater treatment plants (WWTP) without decomposing biologically during the waste treatment process, nor does it attach (through sorption) to particles of activated sludge to any significant extent, therefore, it passes through the system of a WWTP, which may cause the substance to accumulate in the natural environment. For this reason the paper investigates the potential to initiate aerobic biodegradation of PVP in the presence of activated sludge from a municipal wastewater treatment plant. The following agents were selected as the initiators of the biodegradation process - co-substrates: acrylamide, N-acethylphenylalanine and 1-methyl-2-pyrrolidone, a substance with a similar structure to PVP monomer. The biodegradability of PVP in the presence of co-substrates was evaluated on the basis of biological oxygen demand (BOD) as determined via a MicroOxymax O2/CO2/CH4 respirometer. The total substrate concentration in the suspension equaled 400 mg·dm-3, with the ratio between PVP and the cosubstrate being 1:1, while the concentration of the dry activated sludge was 500 mg·dm-3. Even though there was no occurrence of a significant increase in the biodegradation of PVP alone in the presence of a co-substrate, acrylamide appeared to be the most effective type of co-substrate. Nevertheless, a recorded decrease in the slope of biodegradation curves over time may indicate that a process of primary decomposition was underway, which involves the production of metabolites that inhibit activated sludge microorganisms. The resulting products are not identified at this stage of experimentation.


Sign in / Sign up

Export Citation Format

Share Document