scholarly journals Rainwater harvesting: quality assessment and utilization in The Netherlands

2009 ◽  
Vol 8 (2) ◽  
pp. 224-235 ◽  
Author(s):  
F. M. Schets ◽  
R. Italiaander ◽  
H. H. J. L. van den Berg ◽  
A. M. de Roda Husman

The use of roof-collected rainwater as a freely available and sustainable alternative to drinking water produced by drinking water companies increases worldwide. Initially, rainwater is free of microbial contamination, but it may become contaminated by animals and humans or, alternatively, human pathogens may grow in stored rainwater resulting in a significant human health risk from infectious diseases. This three-year study demonstrated that rainwater stored in different reservoirs in The Netherlands was frequently faecally contaminated and incidentally contained potential human pathogens such as Campylobacter, Cryptosporidium, Giardia, Aeromonas hydrophila and Legionella. Analysis of samples during a period with variable weather conditions showed a correlation between rainfall intensity and faecal indicator counts and increased detection of pathogens after heavy rainfall incidents. Outside temperature had a limited effect on both the temperature and the microbiological quality of the water in the reservoirs, which did not comply with Dutch drinking water legislation and should thus not be consumed without treatment. In general, a health risk may arise from exposure to pathogens when contaminated droplets are inhaled, ingested or come into contact with the skin. Health risks may be reduced by regular cleaning of the collection, storage and transport means, but to assess their efficacy field intervention studies are required.

2013 ◽  
Vol 60 ◽  
pp. 93-101 ◽  
Author(s):  
Sardar Khan ◽  
Maria Shahnaz ◽  
Noor Jehan ◽  
Shafiqur Rehman ◽  
M. Tahir Shah ◽  
...  

2018 ◽  
Vol 19 (2) ◽  
pp. 404-416 ◽  
Author(s):  
B. A. Wols ◽  
A. Vogelaar ◽  
A. Moerman ◽  
B. Raterman

Abstract The influence of the weather parameters of temperature, wind and drought on pipe failure of drinking water distribution pipes was studied for the Netherlands. Several data sources were used relating weather effects to pipe failure: pipe failure data, regional weather data from different weather stations in the Netherlands, soil settlement data obtained from satellites and (modelled) pressure data. For asbestos-cement (AC) and cast iron (CI) pipes, temperature was an important factor. CI pipes showed increased pipe failures at low temperatures, which confirms results from previous studies, whereas AC pipes showed increased pipe failures at high temperatures. Pipe failure rates were higher for pipes that on average received higher internal pressures. This study also showed that wind resulted in additional pipe failures caused by uprooting of trees during a severe storm. With respect to drought, in some regions in the Netherlands, increased pipe failures during periods of drought were found. A small influence of soil settlement on pipe failure was found using remote-sensing techniques for a small area (5 × 10 km) in the Netherlands.


2019 ◽  
Vol 180 ◽  
pp. 549-556 ◽  
Author(s):  
Sarva Mangala Praveena ◽  
Maizatul Zahirah Mohd Rashid ◽  
Fauzan Adzima Mohd Nasir ◽  
Wee Sze Yee ◽  
Ahmad Zaharin Aris