scholarly journals Detection of drinking water contamination by an optical real-time bacteria sensor

2018 ◽  
Vol 1 (2) ◽  
pp. 160-168 ◽  
Author(s):  
B. Højris ◽  
S. N. Kornholt ◽  
S. C. B. Christensen ◽  
H.-J. Albrechtsen ◽  
L. S. Olesen

Abstract In a drinking water distribution system, little is known about the characteristics of a microbiological pollution, how it enters the system, and how it can be detected. The drinking water industry has relied on various pollution indicators, through grab sampling and laboratory analyses, revealing results long after the water has been used. To be able to react more proactively to pollution events, many drinking water distributors supplement grab sampling with proportional sampling and/or real-time sensors. We have tested the ability of a new bacteria monitor to detect four different pollution events: wastewater intrusion, rainwater runoff, resuspension of drinking water sediments, and bird droppings entering the distribution system. The monitor response, in terms of bacteria and abiotic particle concentrations, was compared with traditional laboratory methods. The results illustrate the benefits of using such real-time bacteria sensors for monitoring the dynamics of drinking water microbiology and for early warning of potential pollution events.

2009 ◽  
Vol 8 (2) ◽  
pp. 205-211 ◽  
Author(s):  
María Alejandra Córdoba ◽  
Valeria Fernanda Del Coco ◽  
Marta Cecilia Minvielle ◽  
Juan Ángel Basualdo

The objective of this study was to evaluate the influencing factors in the occurrence of coliforms in the drinking water in La Plata (Argentina) from June 1999 to June 2001. A total of 180 samples were collected from Rio de La Plata (102 samples) and Puelche Aquifer (78 samples); 45 samples were collected for each of the four seasons. The membrane filter procedure was used for isolating bacteria, and each sample was tested for chlorine and pH. The highest percentage of samples positive for coliforms in the two tested media was obtained in summer while the highest percentage of negative samples was obtained in winter. No Escherichia coli was isolated. The percentage of injured coliforms fluctuated between 70 and 100%. The most frequently isolated bacteria was Enterobacter cloacae in summer, Enterobacter agglomerans in autumn and Klebsiella oxytoca in winter and spring. Significant correlations were observed between coliforms and the distance from the initial treatment point, and with the level of free chlorine. We conclude that drinking water contamination in La Plata occurs in the distribution system due to increased temperatures and reduced disinfectant levels, which result in bacterial regrowth.


2008 ◽  
Vol 8 (4) ◽  
pp. 421-426
Author(s):  
J. Menaia ◽  
M. Benoliel ◽  
A. Lopes ◽  
C. Neto ◽  
E. Ferreira ◽  
...  

Concerns arise from the possible occurrence of pathogens in drinking water pipe biofilms and storage tank sediments. In these studies, biofilm samples from pipes and sediments from storage tanks of the Lisbon drinking water distribution system were analyzed. Protein determinations and heterotrophic counts on pipe biofilm samples were used to assess the Lisbon network sessile colonization intensity and distribution. Indicator and pathogenic microorganisms were analyzed in pipe biofilm samples, as well as in storage tanks biofilm and sediments, by using cultural methods and PCR, to assess risks. Results have shown that the Lisbon network sessile colonization is relatively weak in intensity. In addition, no meaningful hazards were apparent for both the network biofilm and the storage tanks biofilm and sediments.


2009 ◽  
Vol 43 (20) ◽  
pp. 5005-5014 ◽  
Author(s):  
Jeffrey G. Szabo ◽  
Christopher A. Impellitteri ◽  
Shekar Govindaswamy ◽  
John S. Hall

2007 ◽  
Vol 2007 (1) ◽  
pp. 449-467
Author(s):  
Stacia L. Thompson ◽  
Elizabeth Casman ◽  
Paul Fischbeck ◽  
Mitchell J. Small ◽  
Jeanne M. VanBriesen