Analysis and viability of microturbines in hydraulic networks: a case study

2019 ◽  
Vol 68 (6) ◽  
pp. 474-482
Author(s):  
Ángel Mariano Rodríguez-Pérez ◽  
Inmaculada Pulido-Calvo

Abstract The purpose of this study is to examine the use of hydraulic microturbines to make the most of the hydraulic energy available in pressurized water distribution systems. The study was carried out on suitable points of pressurized hydraulic networks, which are managed by Giahsa, a public enterprise responsible for the management of the municipal communities of services (MAS) in the province of Huelva, southwestern Spain. The distribution system situated between the Cabeza del Pasto reservoir in the Andévalo area (Huelva, Spain) and the wastewater treatment plant (WWTP) in the municipality of Puebla de Guzmán (Huelva, Spain) was examined. To obtain the exact amount of energy which reaches the microturbine, the energy conservation equation considering the loss of energy from friction was used. The results show different locations where it is possible to carry out the installation of a Francis turbine, which can generate an annual energy of approximately 280 MWh per year at the selected point, with an approximate investment cost of €20,000 per year, which means a recovery period of this investment of 2 years.

2006 ◽  
Vol 72 (9) ◽  
pp. 5864-5869 ◽  
Author(s):  
Elizabeth D. Hilborn ◽  
Terry C. Covert ◽  
Mitchell A. Yakrus ◽  
Stephanie I. Harris ◽  
Sandra F. Donnelly ◽  
...  

ABSTRACT There is evidence that drinking water may be a source of infections with pathogenic nontuberculous mycobacteria (NTM) in humans. One method by which NTM are believed to enter drinking water distribution systems is by their intracellular colonization of protozoa. Our goal was to determine whether we could detect a reduction in the prevalence of NTM recovered from an unfiltered surface drinking water system after the addition of ozonation and filtration treatment and to characterize NTM isolates by using molecular methods. We sampled water from two initially unfiltered surface drinking water treatment plants over a 29-month period. One plant received the addition of filtration and ozonation after 6 months of sampling. Sample sites included those at treatment plant effluents, distributed water, and cold water taps (point-of-use [POU] sites) in public or commercial buildings located within each distribution system. NTM were recovered from 27% of the sites. POU sites yielded the majority of NTM, with >50% recovery despite the addition of ozonation and filtration. Closely related electrophoretic groups of Mycobacterium avium were found to persist at POU sites for up to 26 months. Water collected from POU cold water outlets was persistently colonized with NTM despite the addition of ozonation and filtration to a drinking water system. This suggests that cold water POU outlets need to be considered as a potential source of chronic human exposure to NTM.


2021 ◽  
Vol 11 (3) ◽  
pp. 55-63
Author(s):  
Osama Khasraw Mohammed Amin ◽  
Mohammad Zaher Akkad ◽  
Tamás Bányai

Water distribution system (WDS) aims to distribute water from reservoirs or aqueducts to the end-users. This system is part of the water supply network that carries potable water from a central treatment plant or wells to water consumers in order to deliver water sufficiently to meet residential, commercial, industrial, and firefighting requirements. Modern systems aim to solve water distribution systems management problems, such as the lowest cost, and most efficient design by using linear/nonlinear optimization schemes, which are limited by the system size, the number of constraints, and the number of loading conditions. After a literature review for the articles that dealt with this topic, designing two parts of the water distribution system is discussed as a case study in Erbil. Pumps and storage tanks, while optimizing the water distribution system by minimizing the project cost through minimizing the volume of the elevated tank according to the pump working hours.


2002 ◽  
Vol 2 (4) ◽  
pp. 97-104 ◽  
Author(s):  
S. Okabe ◽  
T. Kokazi ◽  
Y. Watanabe

When biodegradable organic matter and other nutrients, such as ammonia and phosphorus, are not sufficiently removed during water treatment, bacteria may proliferate in the water distribution system. Bacterial regrowth deteriorates water quality (taste and odor), accelerates corrosion, and potentially increases the risk of microbial diseases. Therefore, this research was conducted to evaluate the impact of four different advanced water treatment processes, including biological treatments such as a rotating biofilm membrane reactor (RBMR) and a biological activated carbon (BAC) filter and ultrafiltration (UF), on reduction of nutrient levels and biofilm formation potentials of the treated water entering model distribution systems (annular reactors). Our results revealed that biological treatments significantly improved the “biostability” of water leaving from the treatment plant. On average, The RBMR and BAC filter reduced easily assimilable organic carbon (AOC) concentration by half when compared with conventional treatment (multi-media filtration; MF) and ultrafiltration (from 35-49 to 18-23 mg C L-1). Consequently, biofilm formation potential was reduced by a factor of 5 to 10 (from 3,200-5,100 to 490-710 pg ATP cm-2). With respect to “biostability” of water, ultrafiltration was less effective in reducing AOC concentrations. In addition, the impact of chlorine disinfection on biofilm accumulation and AOC levels in the distribution system were studied.


2017 ◽  
Vol 43 (4) ◽  
pp. 3-12 ◽  
Author(s):  
Katarzyna Pietrucha-Urbanik ◽  
Barbara Tchórzewska-Cieślak ◽  
Dorota Papciak ◽  
Izabela Skrzypczak

AbstractThe main goal of this work is to show the new approach to determining safety technological levels (SLs) in terms of water quality and its chemical stability, as well as issues of water corrosion properties in water distribution systems (WDSs), due to the fact that water supply pipes are prone to corrosion. In the paper the methodology of determining the risk associated with threat to technical infrastructure was considered. The concept was studied on the basis of real operational data from the water treatment plant. The probability of exceeding the individual parameters for WTPI is slightly larger than for WTPII, which means that this water treatment process may cause lack of chemical stability in the water supply network. Operators should anticipate in the process of designing water distribution system, using proper materials, as to ensure an adequate level of safety from the water source to the water recipient. It should be noted that it is necessary to adjust the material of internal installation of water supply networks to the parameters of the water. At present, there are no correlations between the designing step and water parameters. It was concluded that to protect the water supply infrastructure, which belongs to critical infrastructure, water company should put more emphasis on distribution of stable water that has not potentially corrosion properties. Some suggestions were made for the protection of WDS and to ensure safety of system functioning and long-term usability of water pipes.


2004 ◽  
Vol 4 (5-6) ◽  
pp. 421-429
Author(s):  
J.C. Ahn ◽  
Y.W. Kim ◽  
K.S. Lee ◽  
J.Y. Koo

Twelve sampling locations in a network from a water treatment plant to consumers' taps were selected for measuring residual chlorine loss, THMs, TOC, etc. and 24 hour sampling in the locations was conducted on a bimonthly basis for one year. Chlorine bulk decay and THM formation tests were carried out by bottle tests under controlled temperatures for three locations: a water treatment plant, a large service reservoir, and a pumping station. Water quality modelling of chlorine loss in the distribution system was performed using data collected in the field study. This study contributed to the improvement of chlorine management in the distribution system by providing information for operators to maintain a minimum level of chlorine residual in a service reservoir.


Water ◽  
2020 ◽  
Vol 12 (6) ◽  
pp. 1818
Author(s):  
Luis Camilo Rosado ◽  
P. López-Jiménez ◽  
Francisco-Javier Sánchez-Romero ◽  
Pilar Conejos Fuertes ◽  
Modesto Pérez-Sánchez

Sustainable development has been an idea raised in recent years. The results are related to the improvement and the use of new technologies to maximize efficiency in water management. However, energy consumption has been increasing as a consequence of new management and uses of water. Especially in pressurized water distribution systems, the use of pressure reduction valves (PRVs) increases the water usage efficiency but it decreases the energy consumption efficiency, since the valves dissipate energy that could be recovered. This research presents a proposal of a recovery system based on the installation of pumps used as turbines (PATs). These machines are located in different points of the high-pressure water distribution system in the Valencia Metropolitan System (Spain). An annual estimate of the theoretical recoverable energy as well as the “ideal” pump for each point were proposed. The theoretical recovered energy value was 847,301 kWh/year for a specific analyzed point. Besides, the characteristic curves of the PATs from a selected point were determined, estimating an improvement in the sustainable indexes. The calculus of these green parameters showed that the implementation of this solution caused a reduction in consumed energy of 1.50 kWh/m3.


2020 ◽  
Vol 21 (2) ◽  
pp. 227-235
Author(s):  
Muhammad Rizki Apritama ◽  
I Wayan Koko Suryawan ◽  
Yosef Adicita

ABSTRACTThe clean water supply system network on Lengkang Kecil Island was developed in 2019. A small portion of the community's freshwater comes from harvesting rainwater and dug wells, which are only obtained during the rainy season. The primary source of clean water used by the community comes from underwater pipelines with a daily discharge of 0.86 l/sec. The water supply of the Lengkang Kecil Island community is 74.3 m3/day, with 146 House Connections (HCs) and to serve public facilities such as elementary schools, primary health centers, and mosques. Hydraulic evaluation of clean water distribution using EPANET 2.0 software on flow velocity shows the lowest rate of 0.29 m/s and the highest of 1.21 m/s. The lowest pressure value in the distribution system is 6.94-6.96 m and headloss units in the range 0.08-0.25 m/km. These three criteria are still within the distribution network design criteria (feasible). A carbon footprint can be calculated from each activity from the analysis of the evaluation of clean water distribution networks. The most massive emissions came from pumping activities with 131 kg CO2-eq, followed by emissions from wastewater 62.5 kgCO2-eq. Further research is needed to determine the quality of wastewater and the design for a centralized wastewater treatment plant (IPALT) to improve Lengkang Kecil Island residents' living standards.Keywords: Lengkang Kecil Island, water, EPANET, carbon footprintABSTRAKJaringan sistem penyediaan air bersih pada Pulau Lengkang Kecil dimulai pada tahun 2019. Sebagian kecil air bersih yang digunakan masyarakat berasal dari pemanenan air hujan dan sumur gali yang hanya didapat pada musim hujan. Sumber air bersih utama yang digunakan masyarakat berasal dari pengaliran perpipaan bawah laut dengan debit harian 0,86 l/detik. Kebutuhan air masyarakat Pulau Lengkang Kecil adalah 74,3 m3/hari dengan 146 Sambungan Rumah (SR) serta untuk melayani fasilitas umum seperti sekolah dasar (SD), puskesmas, dan masjid. Evaluasi hidrolis distribusi air bersih dengan menggunakan software EPANET 2.0 terhadap kriteria kecepatan aliran menunjukkan nilai terendah 0,29 m/s dan tertinggi 1,21 m/s. Nilai sisa tekan dalam sistem distribusi adalah 6,94–6,96 m dan unit headloss pada kisaran 0,08–0,25 m/km. Ketiga kriteria ini masih berada dalam kriteria desain jaringan distribusi (layak). Dari analisis evaluasi jaringan distribusi air bersih, dapat dihitung jejak karbon yang dihasilkan dari setiap kegiatannya. Emisi terbesar berasal dari kegiatan pemompaan dengan nilai 131 kgCO2-eq, diikuti dengan emisi yang berasal dari air limbah dengan nilai 62,5 kgCO2-eq. Penelitian lanjutan diperlukan untuk mengetahui kualitas dari air limbah dan desain untuk instalasi pengolahan air limbah terpusat (IPALT) untuk meningkatkan taraf hidup penduduk Pulau Lengkang Kecil.Kata kunci: Pulau Lengkang Kecil, air, EPANET, jejak karbon


2001 ◽  
Vol 1 (3) ◽  
pp. 91-96 ◽  
Author(s):  
L.J. Hem ◽  
E.A. Vik ◽  
A. Bjørnson-Langen

In 1995 the new Skullerud water treatment plant was put into operation. The new water treatment includes colour removal and corrosion control with an increase of pH, alkalinity and calcium concentration in addition to the old treatment, which included straining and chlorination only. Comparative measurements of internal corrosion were conducted before and after the installation of the new treatment plant. The effect of the new water treatment on the internal corrosion was approximately a 20% reduction in iron corrosion and a 70% reduction in copper corrosion. The heavy metals content in standing water was reduced by approximately 90%. A separate internal corrosion monitoring programme was conducted, studying the effects of other water qualities on the internal corrosion rate. Corrosion coupons were exposed to the different water qualities for nine months. The results showed that the best protection of iron was achieved with water supersaturated with calcium carbonate. Neither a high content of free carbon dioxide or the use of the corrosion inhibitor sodium silicate significantly reduced the iron corrosion rate compared to the present treated water quality. The copper corrosion rate was mainly related to the pH in the water.


2010 ◽  
Vol 13 (3) ◽  
pp. 419-428 ◽  
Author(s):  
Qiang Xu ◽  
Qiuwen Chen ◽  
Weifeng Li

The water loss from a water distribution system is a serious problem for many cities, which incurs enormous economic and social loss. However, the economic and human resource costs to exactly locate the leakage are extraordinarily high. Thus, reliable and robust pipe failure models are demanded to assess a pipe's propensity to fail. Beijing City was selected as the case study area and the pipe failure data for 19 years (1987–2005) were analyzed. Three different kinds of methods were applied to build pipe failure models. First, a statistical model was built, which discovered that the ages of leakage pipes followed the Weibull distribution. Then, two other models were developed using genetic programming (GP) with different data pre-processing strategies. The three models were compared thereafter and the best model was applied to assess the criticality of all the pipe segments of the entire water supply network in Beijing City based on GIS data.


Water ◽  
2021 ◽  
Vol 13 (9) ◽  
pp. 1163
Author(s):  
Mengning Qiu ◽  
Avi Ostfeld

Steady-state demand-driven water distribution system (WDS) solution is the bedrock for much research conducted in the field related to WDSs. WDSs are modeled using the Darcy–Weisbach equation with the Swamee–Jain equation. However, the Swamee–Jain equation approximates the Colebrook–White equation, errors of which are within 1% for ϵ/D∈[10−6,10−2] and Re∈[5000,108]. A formulation is presented for the solution of WDSs using the Colebrook–White equation. The correctness and efficacy of the head formulation have been demonstrated by applying it to six WDSs with the number of pipes ranges from 454 to 157,044 and the number of nodes ranges from 443 to 150,630. The addition of a physically and fundamentally more accurate WDS solution method can improve the quality of the results achieved in both academic research and industrial application, such as contamination source identification, water hammer analysis, WDS network calibration, sensor placement, and least-cost design and operation of WDSs.