scholarly journals Combined 20-gauge and 23-gauge pars plana vitrectomy for the management of posteriorly dislocated lens: a case series

2010 ◽  
pp. 625 ◽  
Author(s):  
Pipat Kongsap
2020 ◽  
Author(s):  
Bahaeddin El Khatib ◽  
Alexander Hacopian ◽  
Menka S. Patel ◽  
Monica Dalal ◽  
H. Nida Sen ◽  
...  

Abstract Sympathetic Ophthalmia (SO) is a rare disease that presents as a bilateral, diffuse, granulomatous panuveitis. Sympathetic Ophthalmia is a clinical diagnosis with history of penetrating ocular injury in the inciting eye and presence of panuveitis in the sympathizing eye. Though early enucleation is believed to minimize the risk, there have been reports of SO even after enucleation of inciting eyes. The possible association between vitrectomy and SO has been initially proposed by Gass [9] and later studied extensively in a large cohort in the UK with an estimated SO risk of 1 in 799 vitrectomies [11]. There have been several case series and reports of SO following vitrectomy, however only three documented cases of SO following vitrectomy without use of silicone oil. These cases demonstrated an onset of SO ranging between 4 weeks to 2 months. We present a patient with SO in the sympathizing eye presenting 16 days after an uncomplicated 23-gauge (23G) sutureless pars plana vitrectomy (PPV) without the use of silicone oil.


2020 ◽  
Author(s):  
Bahaeddin El Khatib ◽  
Menka S. Patel ◽  
Alexander Hacopian ◽  
Monica Dalal ◽  
H. Nida Sen ◽  
...  

Abstract Sympathetic Ophthalmia (SO) is a rare disease that presents as a bilateral, diffuse, granulomatous panuveitis. Sympathetic Ophthalmia is a clinical diagnosis with history of penetrating ocular injury in the inciting eye and presence of panuveitis in the sympathizing eye. Though early enucleation is believed to minimize the risk, there have been reports of SO even after enucleation of inciting eyes. The possible association between vitrectomy and SO has been initially proposed by Gass [9] and later studied extensively in a large cohort in the UK with an estimated SO risk of 1 in 799 vitrectomies [11]. There have been several case series and reports of SO following vitrectomy, however only three documented cases of SO following vitrectomy without use of silicone oil. These cases demonstrated an onset of SO ranging between 4 weeks to 2 months. We present a patient with SO in the sympathizing eye presenting 16 days after an uncomplicated 23-gauge (23G) sutureless pars plana vitrectomy (PPV) without the use of silicone oil.


2020 ◽  
pp. bjophthalmol-2020-317214
Author(s):  
Hasan Naveed ◽  
Fong May Chew ◽  
Hanbin Lee ◽  
Edward Hughes ◽  
Mayank A Nanavaty

PurposeTo assess whether pars plana vitrectomy (PPV) is an aerosol-generating procedure (AGP) in an ex vivo experimental model.MethodsIn this ex vivo study on 10 porcine eyes, optical particle counter was used to measure particles ≤10 μm using cumulative mode in the six in-built channels: 0.3 μm, 0.5 μm, 1 μm, 2.5 μm, 5 μm and 10 μm aerosols during PPV. Two parts of the study were as follows: (1) to assess the pre-experimental baseline aerosol count in the theatre environment where there are dynamic changes in temperature and humidity and (2) to measure aerosol generation with 23-gauge and 25-gauge set-up. For each porcine eye, five measurements were taken for each consecutive step in the experiment including pre-PPV, during PPV, fluid–air exchange (FAX) and venting using a flute with 23-gauge set-up and a chimney with 25-gauge set-up. Therefore, a total of 200 measurements were recorded.ResultsWith 23-gauge and 25-gauge PPV, there was no significant difference in aerosol generation in all six channels comparing pre-PPV versus PPV or pre-PPV versus FAX. Venting using flute with 23-gauge PPV showed significant reduction of aerosol ≤1 μm. Air venting using chimney with 25-gauge set-up showed no significant difference in aerosol of ≤1 μm. For cumulative aerosol counts of all particles measuring ≤5 μm, compared with pre-PPV, PPV or FAX, flute venting in 23-gauge set-up showed significant reduction unlike the same comparison for chimney venting in 25-gauge set-up.ConclusionPPV and its associate steps do not generate aerosols ≤10 μm with 23-gauge and 25-gauge set-ups.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Enchi Kristina Chang ◽  
Sanchay Gupta ◽  
Marika Chachanidze ◽  
John B. Miller ◽  
Ta Chen Chang ◽  
...  

Abstract Purpose The purpose of this study is to report the safety and efficacy of pars plana glaucoma drainage devices with pars plana vitrectomy using one of the vitrectomy sclerotomy sites for tube placement in patients with refractory glaucoma. Methods Retrospective case series of 28 eyes of 28 patients who underwent combined pars plana glaucoma drainage device and pars plana vitrectomy between November 2016 and September 2019 at Massachusetts Eye and Ear. Main outcome measures were intraocular pressure (IOP), glaucoma medication burden, best corrected visual acuity, and complications. Statistical tests were performed with R and included Kaplan-Meier analyses, Wilcoxon paired signed-rank tests, and Fisher tests. Results Mean IOP decreased from 22.8 mmHg to 11.8 mmHg at 1.5 years (p = 0.002), and mean medication burden decreased from 4.3 to 2.1 at 1.5 years (p = 0.004). Both IOP and medication burden were significantly lower at all follow-up time points. The probability of achieving 5 < IOP ≤ 18 mmHg with at least 20% IOP reduction from preoperative levels was 86.4% at 1 year and 59.8% at 1.5 years. At their last visit, three eyes (10.7%) achieved complete success with IOP reduction as above without medications, and 14 eyes (50.0%) achieved qualified success with medications. Hypotony was observed in 1 eye (3.6%) prior to 3 months postoperatively and 0 eyes after 3 months. Visual acuity was unchanged or improved in 23 eyes (82.1%) at their last follow-up. Two patients had a visual acuity decrease of > 2 lines. Two eyes required subsequent pars plana vitrectomies for tube obstruction, and one eye had transient hypotony. Conclusions The results of pars plana glaucoma drainage device and pars plana vitrectomy using one of the vitrectomy sclerotomy sites for tube placement are promising, resulting in significant IOP and medication-burden reductions through postoperative year 1.5 without additional risk of postoperative complications. Inserting glaucoma drainage devices into an existing vitrectomy sclerotomy site may potentially save surgical time by obviating the need to create another sclerotomy for tube placement and suture one of the vitrectomy ports.


Author(s):  
Ramandeep Singh ◽  
Neha Kumari ◽  
Deeksha Katoch ◽  
Gaurav Sanghi ◽  
Amod Gupta ◽  
...  

2016 ◽  
Vol 7 (3) ◽  
pp. 433-439
Author(s):  
Spyridon E. Chalkiadakis ◽  
Efstratios A. Parikakis ◽  
Simon R.J. Taylor

Background: The surgical case of a dropped intraocular lens inside the vitreous cavity constitutes a real challenge for the operating surgeon. Herein, we describe a case series where an alternative optical rehabilitation technique for late intraocular lens-bag complex dislocation has been used. Methods: A modern vitrectomy device was used to remove the capsule with the dropped intraocular lens using sutureless 25-gauge pars plana vitrectomy. To ensure a better aesthetic result, with faster patient recovery and a reduced number of operations, the whole procedure was performed during the same operating session; an iris-claw intraocular lens for aphakia was selected for implantation. The implant was passed behind the constricted iris with the concave surface facing it. The lens was grasped with the manufacturer’s holding forceps and fixed onto the posterior surface of the iris using the special enclavation needles. Results: We have operated 12 eyes in two different clinical centres successfully, with minimal intra- and/or postoperative complications. Conclusion: We believe that this is a viable solution for the visual rehabilitation of patients, who would otherwise need more than one operation for a lens exchange.


2019 ◽  
Vol 2019 ◽  
pp. 1-6 ◽  
Author(s):  
Fabrizio Giansanti ◽  
Ruggero Tartaro ◽  
Tomaso Caporossi ◽  
Daniela Bacherini ◽  
Alfonso Savastano ◽  
...  

Introduction. Recurrent or persistent macular holes (MHs) are rare today due to the tendency to carefully peel the internal limiting membrane. Conversely, their treatment is still a challenge for a vitreoretinal surgeon. Materials and Methods. This is a retrospective, consecutive, and nonrandomized study of patients affected by recurrent or persistent MHs treated using small-gauge pars plana vitrectomy (25- or 23-gauge) and an autologous ILM plug, at the Eye Clinic of Azienda Ospedaliera Universitaria Careggi (Florence, Italy) between January 2016 and May 2018. We included 8 eyes of 8 patients in the study. Five patients had a recurrent MH while 3 had a persistent MH. The case series includes patients with myopic eyes and with large macular holes (>400 μ). Patients were followed up with ophthalmoscopic examinations and swept-source optical coherence tomography (SS-OCT). Results. The mean age of the patients was 74 years (±4.81 standard deviation (SD)), 3 patients were men and 5 women. The average axial length was 26.28 mm (±2.84 SD). Four patients had an AL ≧ 26 mm. The mean MH diameter was 436.5 (±49.82 SD). Average preoperative best-corrected visual acuity (BCVA) was 0.81 logMAR (±0.16 SD) and 20/125 Snellen. The ILM plug has been found integrated in the MH in all the follow-ups. Conclusion. In our study, an ILM autologous macular transplant was used successfully in 5 cases of macular hole recurrence and 3 cases of macular hole persistence. The anatomical success was achieved in all the cases; 4 patients improved their BCVA, and 4 patients maintained it. No macular alterations such as RPE or retinal atrophy/dystrophy were observed after 6 months.