scholarly journals Heat Development in the Pulp Chamber During Curing Process of Resin-Based Composite Using Multi-Wave LED Light Curing Unit

2020 ◽  
Vol Volume 12 ◽  
pp. 271-280
Author(s):  
Bo Wold Nilsen ◽  
Mathieu Mouhat ◽  
Torbjørn Haukland ◽  
Ulf Thore Örtengren ◽  
James B Mercer
2016 ◽  
Vol 7 (3) ◽  
pp. 184-191 ◽  
Author(s):  
Rajesh Harivadanbhai Mahant ◽  
Shraddha Chokshi ◽  
Rupal Vaidya ◽  
Pruthvi Patel ◽  
Asima Vora ◽  
...  

2020 ◽  
Author(s):  
RQ Ramos ◽  
RR Moraes ◽  
GC Lopes

Clinical Relevance The use of multipeak LED light-curing guarantees efficiency on light activation of Ivocerin-containing light-cured resin cement.


10.2341/05-26 ◽  
2006 ◽  
Vol 31 (2) ◽  
pp. 261-265 ◽  
Author(s):  
A. R. Yazici ◽  
A. Müftü ◽  
G. Kugel ◽  
R. D. Perry

Clinical Relevance The thickness of the residual dentin is a critical factor in the reducing thermal transfer to pulp, and this transfer varies with the curing unit used.


2019 ◽  
Vol 73 (4) ◽  
pp. 239-248
Author(s):  
Violeta Petrovic ◽  
Jovana Stasic ◽  
Vojislav Komlenic ◽  
Tatjana Savic-Stankovic ◽  
Marina Latkovic ◽  
...  

The objective of this study was to measure temperature changes in the pulp chamber induced by polymerization of resin-based dental restoratives following a simulated procedure of direct pulp capping. Class I cavities with a microperforation at the pulp horn were prepared in extracted human molar teeth. The complete procedure of direct pulp capping and cavity restoration was performed with the root part of extracted teeth fixed in a water bath at 37 ?C. Mineral trioxide aggregate, bioactive dentin substitute or calcium-hydroxide paste were used as pulp capping materials. Cavities were restored with a light-cured or chemically-cured resin-modified glass ionomer, universal adhesive and a bulk-fill composite, cured with a high-intensity LED unit. Pulp capping materials caused a slight temperature decrease. Lower temperature increase was recorded during light-curing of the glass ionomer liner after direct capping with mineral trioxide aggregate and calcium-hydroxide than that recorded for the bioactive dentin substitute. Adhesive light-curing increased temperature in all groups with higher mean temperatures in groups with chemically-cured as compared to those for the light-cured glass ionomer liner. Direct pulp capping with mineral trioxide aggregate or calcium-hydroxide followed by the light-cured resin-modified glass ionomer liner and a bonded bulk-fill composite restoration induced temperature changes below the potentially adverse threshold of 42.5?C.


2021 ◽  
Author(s):  
A Altaie ◽  
MA Hadis ◽  
V Wilson ◽  
MJ German ◽  
BR Nattress ◽  
...  

SUMMARY Objective: This study aimed to evaluate the irradiance and the quality of LED light curing units (LCUs) in primary and secondary clinics in the UK and to assess the effect of damage, contamination, use of protective sleeves, and distance of light tips to target on the irradiance and performance of LCUs. Methods: The irradiance levels (mW/cm2) of 26 LED LCUs from general dental practices and 207 LED LCUs from two dental hospitals were measured using a digital radiometer (Blue Phase II, Ivoclar, Vivadent, Amherst, NY). Ten LED light guide tips (Satelec Mini, Acteon, Merignac, France) were selected to evaluate the effect of chipping, contamination (tip debris), and use of protective sleeves and tips to sensor distance on irradiance (mW/cm2) using a MARC Resin Calibrator (Blue Light Analytics, Halifax, Canada). Homogeneity of the light output was evaluated using a laser beam profiler (SP620; Ophir-Spiricon, North Longan, UT, USA). Statistical analysis was conducted using a one-way analysis of variance (ANOVA) with post hoc Tukey test (α=0.05) and linear regression with stepwise correlation tests. Results: Thirty-three percent of the LCUs delivered irradiance output less than 500 mW/cm2. The condition of the light curing tips was poor, with 16% contaminated with resin debris, 26% damaged, and 10% both contaminated and damaged. The irradiance output was significantly reduced in contaminated (62%) and chipped (50%) light curing tips and when using protective sleeves (24%) (p<0.05). Irradiance was also reduced when increasing the distance with 25% and 34% reduction at 7 mm and 10 mm, respectively (p<0.05). Conclusion: There remains a lack of awareness of the need for regular monitoring and maintenance of dental LCUs. Damaged and contaminated light curing tips, use of protective sleeves, and increasing the distance from the restoration significantly reduced the irradiance output and the performance of the LCUs.


2015 ◽  
Vol 31 (5) ◽  
pp. 505-513 ◽  
Author(s):  
Patrício Runnacles ◽  
Cesar Augusto Galvão Arrais ◽  
Marcia Thais Pochapski ◽  
Fábio André dos Santos ◽  
Ulisses Coelho ◽  
...  