Baseline monitoring for time-lapse pressure tomography: Initial results from Otway Stage 3

2021 ◽  
Author(s):  
Samuel Jackson ◽  
James Gunning ◽  
Jonathan Ennis-King ◽  
Charles Jenkins ◽  
Tess Dance ◽  
...  
2020 ◽  
Author(s):  
Peter Talling ◽  
Ricardo de Silva Jacinto ◽  
Megan Baker ◽  
Ed Pope ◽  
Maarten Heijnen ◽  
...  

<p>Turbidity currents form many of the largest sediment accumulations, longest channels, and deepest canyons on our planet. These seabed sediment avalanches can be very (> 10 m/s) fast, runout for hundreds of kilometres, and break seabed cables that now form the backbone of the internet and global data transfer. It was once thought that detailed monitoring of turbidity currents in action was impractical, ensuring these flows were relatively poorly understood. However, a series of recent projects have used new approaches and technology to show how these flows can be measured in shallow water (< 2 km) settings, such as Monterey Canyon and Canadian fjords, where flows ran out for < ~50 km and had speeds of up to 8 m/s. Here we present initial results from an ambitious project to measure active flows that runout for >1,000 km to form a major submarine fan in the deep ocean. The project studies the Congo submarine canyon-channel system that extends for ~1,100 km from the mouth of the Congo River, offshore West Africa. Monitoring in 2010 at a single site in the upper Congo Canyon had previously shown that flows are active for ~30% of the time, and reach speeds of up to 3 m/s. In this new project, direct flow monitoring at 11 sites are being combined with detailed time-lapse mapping and coring of flow deposits, through a series of 4 or 5 major research cruises from 2019 to 2023. Here we present initial results from the first of these cruises (JC187) in August-to-October 2019, which placed 11 moorings with sensors at water depths of 1.6 to 5.5 km. The presentation will initially focus on the geomorphology of the channel system, and how it varies down-slope and through time. For example, it is apparent that a landslide partly blocked one location in the upper canyon in the last 20 years, causing meander bend cut-off and sediment ponding. The talk will then discuss models for how submarine channel bends evolve, and the implications for channel deposits. Recent work in sandy submarine channels suggests that they can be dominated by very fast-moving knickpoints (waterfall like features). However, the much muddier Congo channel displays well-developed meander bend bars for which cores are available. We therefore start to show how muddy deep-sea channels may differ in significant ways from their sandier cousins in shallow water. </p>


Author(s):  
Raul I. Garcia ◽  
Evelyn A. Flynn ◽  
George Szabo

Skin pigmentation in mammals involves the interaction of epidermal melanocytes and keratinocytes in the structural and functional unit known as the Epidermal Melanin Unit. Melanocytes(M) synthesize melanin within specialized membrane-bound organelles, the melanosome or pigment granule. These are subsequently transferred by way of M dendrites to keratinocytes(K) by a mechanism still to be clearly defined. Three different, though not necessarily mutually exclusive, mechanisms of melanosome transfer have been proposed: cytophagocytosis by K of M dendrite tips containing melanosomes, direct injection of melanosomes into the K cytoplasm through a cell-to-cell pore or communicating channel formed by localized fusion of M and K cell membranes, release of melanosomes into the extracellular space(ECS) by exocytosis followed by K uptake using conventional phagocytosis. Variability in methods of transfer has been noted both in vivo and in vitro and there is evidence in support of each transfer mechanism. We Have previously studied M-K interactions in vitro using time-lapse cinemicrography and in vivo at the ultrastructural level using lanthanum tracer and freeze-fracture.


Author(s):  
Avril V. Somlyo ◽  
H. Shuman ◽  
A.P. Somlyo

This is a preliminary report of electron probe analysis of rabbit portal-anterior mesenteric vein (PAMV) smooth muscle cryosectioned without fixation or cryoprotection. The instrumentation and method of electron probe quantitation used (1) and our initial results with cardiac (2) and skeletal (3) muscle have been presented elsewhere.In preparations depolarized with high K (K2SO4) solution, significant calcium peaks were detected over the sarcoplasmic reticulum (Fig 1 and 2) and the continuous perinuclear space. In some of the fibers there were also significant (up to 200 mM/kg dry wt) calcium peaks over the mitochondria. However, in smooth muscle that was not depolarized, high mitochondrial Ca was found in fibers that also contained elevated Na and low K (Fig 3). Therefore, the possibility that these Ca-loaded mitochondria are indicative of cell damage remains to be ruled out.


Author(s):  
J.N. Turner ◽  
W.G. Shain ◽  
V. Madelian ◽  
R.A. Grassucci ◽  
D.L. Forman

Homogeneous cultures of astroglial cells have proved useful for studying biochemical, pharmacological, and toxicological responses of astrocytes to effectors of central nervous system function. LRM 55 astroglial cells, which were derived from a rat glioma and maintained in continuous culture, exhibit a number of astrocyte properties (1-3). Stimulation of LRM 55s and astrocytes in primary cell cultures with the beta-adrenergic agonist isoproterenol results in rapid changes of morphology. Studies with time lapse video light microscopy (VLM) and high-voltage electron microscopy (HVEM) have been correlated to changes in intracellular levels of c-AMP. This report emphasizes the HVEM results.


Author(s):  
R H. Selinfreund ◽  
A. H. Cornell-Bell

Cellular electrophysiological properties are normally monitored by standard patch clamp techniques . The combination of membrane potential dyes with time-lapse laser confocal microscopy provides a more direct, least destructive rapid method for monitoring changes in neuronal electrical activity. Using membrane potential dyes we found that spontaneous action potential firing can be detected using time-lapse confocal microscopy. Initially, patch clamp recording techniques were used to verify spontaneous electrical activity in GH4\C1 pituitary cells. It was found that serum depleted cells had reduced spontaneous electrical activity. Brief exposure to the serum derived growth factor, IGF-1, reconstituted electrical activity. We have examined the possibility of developing a rapid fluorescent assay to measure neuronal activity using membrane potential dyes. This neuronal regeneration assay has been adapted to run on a confocal microscope. Quantitative fluorescence is then used to measure a compounds ability to regenerate neuronal firing.The membrane potential dye di-8-ANEPPS was selected for these experiments. Di-8- ANEPPS is internalized slowly, has a high signal to noise ratio (40:1), has a linear fluorescent response to change in voltage.


Author(s):  
W.F. Marshall ◽  
K. Oegema ◽  
J. Nunnari ◽  
A.F. Straight ◽  
D.A. Agard ◽  
...  

The ability to image cells in three dimensions has brought about a revolution in biological microscopy, enabling many questions to be asked which would be inaccessible without this capability. There are currently two major methods of three dimensional microscopy: laser-scanning confocal microscopy and widefield-deconvolution microscopy. The method of widefield-deconvolution uses a cooled CCD to acquire images from a standard widefield microscope, and then computationally removes out of focus blur. Using such a scheme, it is easy to acquire time-lapse 3D images of living cells without killing them, and to do so for multiple wavelengths (using computer-controlled filter wheels). Thus, it is now not only feasible, but routine, to perform five dimensional microscopy (three spatial dimensions, plus time, plus wavelength).Widefield-deconvolution has several advantages over confocal microscopy. The two main advantages are high speed of acquisition (because there is no scanning, a single optical section is acquired at a time by using a cooled CCD camera) and the use of low excitation light levels Excitation intensity can be much lower than in a confocal microscope for three reasons: 1) longer exposures can be taken since the entire 512x512 image plane is acquired in parallel, so that dwell time is not an issue, 2) the higher quantum efficiently of a CCD detect over those typically used in confocal microscopy (although this is expected to change due to advances in confocal detector technology), and 3) because no pinhole is used to reject light, a much larger fraction of the emitted light is collected. Thus we can typically acquire images with thousands of photons per pixel using a mercury lamp, instead of a laser, for illumination. The use of low excitation light is critical for living samples, and also reduces bleaching. The high speed of widefield microscopy is also essential for time-lapse 3D microscopy, since one must acquire images quickly enough to resolve interesting events.


2001 ◽  
Vol 120 (5) ◽  
pp. A226-A226 ◽  
Author(s):  
W LAMMERS ◽  
S DHANASEKARAN ◽  
J SLACK ◽  
B STEPHEN

2007 ◽  
Vol 177 (4S) ◽  
pp. 364-364 ◽  
Author(s):  
Surena F. Matin ◽  
Christopher G. Wood ◽  
Shi-Ming Tu ◽  
Nizar M. Tannir ◽  
Eric Jonasch

Sign in / Sign up

Export Citation Format

Share Document