scholarly journals Detecting In-Vitro Colistin Resistance- A Comparative Study Between Broth Microdilution Versus Vitek-2 For Colistin Susceptibility Testing

2020 ◽  
Vol 7 (7) ◽  
pp. A336-340
Author(s):  
Hena Butta ◽  
Leena Mendiratta ◽  
Raman Sardana ◽  
Kirti Gilotra ◽  
Sana Hasan ◽  
...  

Background: Susceptibility testing for polymyxins is a great challenge for a Clinical Microbiology laboratory. There are several methodological issues associated with MIC (Minimum Inhibitory Concentration) determination of colistin. Methods: In our study, we have compared the results of colistin susceptibility testing by Automated system (Vitek-2, Biomerieux, France) with the reference Broth Microdilution method (BMD) to identify the type of discrepancies by Vitek-2 method and thus develop a practical and accurate approach for colistin susceptibility testing in a Clinical Microbiology laboratory. A total of 730 strains of Gram negative bacteria [Escherichia coli (325), Klebsiella sp.(346), Acinetobacter baumanii complex (37) and Pseudomonas aeruginosa (22)] from 485 patents were tested simultaneously by BMD and Vitek-2 method for colistin susceptibility testing. Results: The Essential agreement (EA), Categorical agreement (CA), Very major error (VME) and Major error (ME) rates for Klebsiella sp. were 87.3%, 89.3%, 8% and 2.3% respectively, for Escherichia coli were 88.3%, 89.5%, 9.2% and 1.2%  respectively, for Acinetobacter baumannii complex were 89.1%, 91.8%, 8.1% and 0% respectively, for Pseudomonas aeruginosa were 68.1%, 72.7%, 0% and 27.2% respectively. Conclusions: Colistin susceptibility testing by Vitek-2 method is an easily adoptable method and the results of Vitek-2 with reference to BMD are acceptable to a great extent in Klebsiella sp., Escherichia coli and Acinetobacter baumanii complex. So, we believe that Vitek-2 method may be used for colistin susceptibility testing in low risk patients. However, BMD should be used in high risk immunosupressed and immunocompromised patients who are admitted in critical care units. For Pseudomonas aeruginosa, BMD should be routinely used.

Author(s):  
Romney Humphries ◽  
Shelley Campeau ◽  
Thomas E. Davis ◽  
Kristin J. Nagaro ◽  
Vincent J. LaBombardi ◽  
...  

In this multisite study, VITEK® 2 AST-Gram-Negative Ceftazidime-Avibactam (CZA) test results for 1073 isolates (866 Enterobacterales and 207 Pseudomonas aeruginosa) were compared to the Clinical & Laboratory Standards Institute (CLSI) broth microdilution (BMD) reference method. The results were analyzed for essential agreement (EA), category agreement (CA), major error rates, and very major error rates following FDA/ISO performance criteria using the FDA-recognized CLSI/EUCAST breakpoints (S ≤8/4 μg/ml and R ≥16/4 μg/ml). The overall EA was 94.5% (1014/1073) and CA was 98.7% (1059/1073). No very major errors were reported. The major error rate was 1.4% (14/998). Out of 14 major errors, 9 were within EA. Based on the EA and lack of an intermediate category for CZA, the adjusted major error rate for FDA criteria was 0.5% (5/998). The performance for ISO criteria after error resolutions included EA 94.5% (1014/1073), CA 98.9% (1061/1073), major error 1.2% (12/998), and no very major error. Vitek 2 met the ISO and FDA criteria of ≥95% reproducibility and ≥95% quality control (QC) results within acceptable ranges for QC organisms. Vitek 2 overall performance for Enterobacterales and P. aeruginosa met or exceeded the FDA and ISO performance criteria and thus is a reliable alternative to BMD reference method for routine CZA susceptibility testing.


1976 ◽  
Vol 4 (6) ◽  
pp. 511-514
Author(s):  
M J Hicks ◽  
K J Ryan

A brief, simplified scheme involving the spot indole test and colonial morphology was evaluated for genus level identification of prompt lactose-fermenting (PLF) members of the Enterobacteriaceae. One hundred and ninety-four consecutive, clinically important PLF gram-negative rods isolated in a clinical microbiology laboratory were identified by this simplified scheme, as well as by standard biochemical tests, and the API 20E (Analytab Products, Inc., Plainview, N.Y.) system. In the simplified scheme a flat, spot indole-positive colony was identified as Escherichia coli. Spot indole-negative organisms forming nucoid colonies were identified as Klebsiella sp. or Enterobacter sp. on the basis of semisolid motility and ornithine decarboxylase tests. Approximately 94% of the study isolates followed reactions typical for E. coli, Klebsiella sp., and Enterobacter sp. as defined by this simplified scheme. When compared with the standard and Analytab Products Inc. identifications, the overall accuracy was 97.4%. The accuracy of identification of E. coli, Klebsiella sp., and Enterobacter sp. was 98.1%, 95.6%, and 87.5%, respectively. This simplified scheme is recommended for identification of selected PLF isolates in the clinical microbiology laboratory.


2015 ◽  
Vol 59 (8) ◽  
pp. 5036-5039 ◽  
Author(s):  
Ronald N. Jones ◽  
Nicole M. Holliday ◽  
Kevin M. Krause

ABSTRACTCeftazidime-avibactam is a broad-spectrum-β-lactamase inhibitor combination in late-stage clinical development for the treatment of serious infections. In preparation for clinical microbiology laboratory use, a validation experiment was initiated to evaluate a commercial broth microdilution product (Sensititre dried MIC susceptibility system) compared to reference panels using 525 recent clinical isolates. Among 11 pathogen groups, all had Sensititre MIC/reference MIC ratios predominantly at 1 (47.5% to 97.5%), and automated and manual endpoint results did not differ.EnterobacteriaceaeMIC comparisons showed a modest skewing of Sensititre MIC results toward an elevated MIC (33.9%), but the essential agreement was 98.9% with 100.0% reproducibility. In conclusion, Sensititre panels produced accurate ceftazidime-avibactam MIC results, allowing quality MIC guidance for therapy following regulatory approvals.


Author(s):  
Elisa Rampacci ◽  
Michele Trotta ◽  
Caterina Fani ◽  
Serenella Silvestri ◽  
Valentina Stefanetti ◽  
...  

Staphylococcus pseudintermedius is the primary cause of canine cutaneous infections and sporadically isolated as pathogen from humans. Rapidly emerging antibiotic-resistant strains are creating serious health concern so that accurate and timely antimicrobial susceptibility testing (AST) is crucial for patient care. Here, the performances of AST methods Vitek-2, Disk Diffusion (DD) and Broth Microdilution (BMD) were compared for the determination of susceptibility of 79 S. pseudintermedius isolates from canine cutaneous infections and one from human pyoderma to oxacillin (OXA), amoxicillin/clavulanate (AMC), cephalothin (CEF), gentamicin (GEN), enrofloxacin (ENR), doxycycline (DOX), clindamycin (CLI), inducible clindamycin resistance (ICR), mupirocin (MUP) and trimethoprim-sulfamethoxazole (SXT). Overall, the agreement of DD and Vitek-2 using veterinary AST-GP80 card with reference BMD was ≥ 90%, suggesting reliable AST performances. While DD generated mainly minor errors and one major error for OXA, Vitek-2 produced one very major error for GEN and it failed in identifying one ICR-positive isolate. Moreover, five bacteria were diagnosed as ICR-positive by Vitek-2 but they showed a non-induction resistance phenotype by manual methods. All S. pseudintermedius were interpreted as susceptible or intermediately susceptible to DOX using CLSI breakpoints for human staphylococci that match the DOX concentration range included in AST-GP80. However, this could lead to inappropriate antimicrobial prescription for S. pseudintermedius infections in companion animals. Considering the clinical and epidemiological importance of S. pseudintermedius , we encourage updating action by the system manufacturer to address AST for this bacterium.


2014 ◽  
Vol 63 (2) ◽  
pp. 235-241 ◽  
Author(s):  
Angella Charnot-Katsikas ◽  
Vera Tesic ◽  
Sue Boonlayangoor ◽  
Cindy Bethel ◽  
Karen M. Frank

This study assessed the accuracy of bacterial and yeast identification using the VITEK MS, and the time to reporting of isolates before and after its implementation in routine clinical practice. Three hundred and sixty-two isolates of bacteria and yeast, consisting of a variety of clinical isolates and American Type Culture Collection strains, were tested. Results were compared with reference identifications from the VITEK 2 system and with 16S rRNA sequence analysis. The VITEK MS provided an acceptable identification to species level for 283 (78 %) isolates. Considering organisms for which genus-level identification is acceptable for routine clinical care, 315 isolates (87 %) had an acceptable identification. Six isolates (2 %) were identified incorrectly, five of which were Shigella species. Finally, the time for reporting the identifications was decreased significantly after implementation of the VITEK MS for a total mean reduction in time of 10.52 h (P<0.0001). Overall, accuracy of the VITEK MS was comparable or superior to that from the VITEK 2. The findings were also comparable to other studies examining the accuracy of the VITEK MS, although differences exist, depending on the diversity of species represented as well as on the versions of the databases used. The VITEK MS can be incorporated effectively into routine use in a clinical microbiology laboratory and future expansion of the database should provide improved accuracy for the identification of micro-organisms.