Dynamic Error Analysis of Measurement While Drilling Using Variable Geomagnetic In-Field Referencing

SPE Journal ◽  
2018 ◽  
Vol 23 (06) ◽  
pp. 2327-2338 ◽  
Author(s):  
Hojjat Kabirzadeh ◽  
Elena Rangelova ◽  
Gyoo Ho Lee ◽  
Jaehoon Jeong ◽  
Ik Woo ◽  
...  

Summary The safe and economical determination of a wellbore trajectory in directional drilling is traditionally achieved by measurement-while-drilling (MWD) methods, which implement magnetic north-seeking sensor packages. Inaccuracies in the determination of well path arise because of random and systematic errors in the measurements of the sensors. Multistation analysis (MSA) and magnetic in-field referencing (IFR) have already demonstrated the potential to decrease the effects of errors because of magnetization of drillstring components along with variable errors caused by irregularities in the magnetization of crustal rocks in the vicinity of wells. Advanced MSA methodologies divide a borehole into several sections and use the average reference values of the total magnetic field, declination, and dip angle for analysis of errors in each section. Our investigations indicate that the variable-reference MSA (VR-MSA) can lead to a better determination of errors, specifically in areas of high magnetization. In this methodology, magnetic reference values are estimated at each station using forward and inverse modeling of surface-magnetic observations from IFR surveys. The fixed errors in magnetometer components are then calculated by minimizing the variance of the difference between the measured and unique estimated reference values at each station. A Levenberg-Marquardt algorithm (LMA) is adopted to solve the nonlinear optimization problem. Examination of this methodology using MWD data confirms more than 20% improvement in well-path-determination accuracy by comparing the results with the corrected path from the conventional MSA method and gyro surveys.

2010 ◽  
Vol 138 (5-6) ◽  
pp. 297-299 ◽  
Author(s):  
Milos Jesic ◽  
Maja Jesic ◽  
Tamara Krstajic ◽  
Zoran Vujnovic ◽  
Nedjo Cutura ◽  
...  

Introduction Haemoglobin saturation is an obligatory oxygen parameter in the assessment of neonatal oxygenation. Although, pulse oximetry is currently one of the major methods in the determination of haemoglobin saturation, capillary blood saturation is still present in the diagnostic process. As well known, haemoglobin saturation value of capillary blood is insufficiently accurate, but not as much as the difference in relation to the values determined by pulse oximetry. Until now published studies have reported that capillary samples are obtained according to a protocol by the principle of free blood outflow, which is practically almost unachievable in the neonate. Objective Determination of the reference values of oxygen saturation (ScO2) and partial pressure (pcO2) of capillary blood by squeezing of the foot. The determination of difference between ScO2 and pulse oximetry (SpO2). Methods In 134 term newborns, we determined SpO2 . Subsequently, we measured the values of ScO2 and pcO2 from the same extremity. While withdrawing a capillary sample, we exerted multiple squeezing of the foot. The mean value of ScO2, pcO2, SpO2 and the difference between ScO2 and SpO2 were determined. Results Mean ScO2 value was 80.5?}8.5%, pcO2 was 48.2?}11.4 mm Hg and SpO2 was 98?}1.9%. The difference between ScO2 and SpO2 values was 17.5?}8.6% (t=23.568; p=0.000). Conclusion There is a statistically highly significant difference between the values of ScO2 and SpO2. Having the knowledge of this difference can increase the accuracy of clinical evaluation and further diagnostics. Comparison in up-to-now conducted studies suggests that the squeezing of the foot for obtaining a capillary sample in relation to free blood outflow does not bear any significant influence on the resultant values of haemoglobin saturation. .


1975 ◽  
Vol 26 ◽  
pp. 341-380 ◽  
Author(s):  
R. J. Anderle ◽  
M. C. Tanenbaum

AbstractObservations of artificial earth satellites provide a means of establishing an.origin, orientation, scale and control points for a coordinate system. Neither existing data nor future data are likely to provide significant information on the .001 angle between the axis of angular momentum and axis of rotation. Existing data have provided data to about .01 accuracy on the pole position and to possibly a meter on the origin of the system and for control points. The longitude origin is essentially arbitrary. While these accuracies permit acquisition of useful data on tides and polar motion through dynamio analyses, they are inadequate for determination of crustal motion or significant improvement in polar motion. The limitations arise from gravity, drag and radiation forces on the satellites as well as from instrument errors. Improvements in laser equipment and the launch of the dense LAGEOS satellite in an orbit high enough to suppress significant gravity and drag errors will permit determination of crustal motion and more accurate, higher frequency, polar motion. However, the reference frame for the results is likely to be an average reference frame defined by the observing stations, resulting in significant corrections to be determined for effects of changes in station configuration and data losses.


1962 ◽  
Vol 41 (1) ◽  
pp. 123-128 ◽  
Author(s):  
Pentti A. Järvinen ◽  
Sykkö Pesonen ◽  
Pirkko Väänänen

ABSTRACT The fractional determination of 17-ketosteroids in the daily urine was performed in nine cases of hyperemesis gravidarum and in four control cases, in the first trimester of pregnancy both before and after corticotrophin administration. The excretion of total 17-KS is similar in the two groups. Only in the hyperemesis group does the excretion of total 17-KS increase significantly after corticotrophin administration. The fractional determination reveals no difference between the two groups of patients with regard to the values of the fractions U (unidentified 17-KS), A (androsterone) and Rest (11-oxygenated 17-KS). The excretion of dehydroepiandrosterone is significantly higher in the hyperemesis group than in the control group. The excretion of androstanolone seems to be lower in the hyperemesis group than in the control group, but the difference is not statistically significant. The differences in the correlation between dehydroepiandrosterone and androstanolone in the two groups is significant. The high excretion of dehydroepiandrosterone and low excretion of androstanolone in cases of hyperemesis gravidarum is a sign of adrenal dysfunction.


Author(s):  
A. D. Terenteva

In civil engineering in Russia, trenching for utilities is currently under digging. To perform such works, it is necessary to use high-precision construction machinery, because inaccurate performance of works can lead to the break down of existing utilities, thereby affecting the residents of nearby houses and demanding the additional works for renewal.The most universal labour saver to perform construction works is hydraulic driven single-bucket excavators, which provide up to 38% of works. Therefore, to improve technical characteristics that affect the accuracy of the work performed is an important task.High requirements for the performance of works are defined by existing construction regulations: an allowable soil layer to remain is at most 0.05 m. To fulfil such requirements, an exact assessment of the working mechanism position and a trench profile is necessary.Examination of a manually operated digging process shows that an operator provides operations untimely, however an automated control system can solve this problem. Dynamic phenomena in the working mechanism have the greatest impact on the accuracy of the works performed.To assess the bucket digging edge position accuracy, a mathematical model of the working mechanism has been created. Based on the cycle scheme of the working process, the excessive displacements of the hydraulic cylinder rods under the load are taken into account. By the end of the cycle, the difference between the specified and obtained positions along the vertical coordinate has been 0.0892 m.A dynamic error of the hydraulic drive system of the working mechanism is considered as a sum of the error due to excessive displacements of the hydraulic cylinder rods and the error due to delay of the hydraulic drive, with the latter being calculated for the average time of delay taking into account the data available in the literature. The total error of the bucket digging edge position of the working mechanism is 0.1176 m, which is 2 times more than the value of 0.05 mConformity of all the links with specification requirements does not guarantee compliance with the required displacement accuracy of the bucket digging edge, and, thus, the soil layer to remain in the base of the trench can exceed the regulated value of 0.05 m.


Author(s):  
Irina Mordous

The development of modern civilization attests to its decisive role in the progressive development of institutions. They identified the difference between Western civilization and the rest of the world. Confirmation of the institutional advantages of the West was its early industrialization. The genesis and formation of institutionalism in its ideological and conceptualmethodological orientation occurs as a process alternative to neoclassic in the context of world heterodoxia, which quickly spread in social science. Highlighting institutional education as a separate area of sociocultural activity is determined by the factor of differentiation of institutional theory as a whole. A feature of institutional education is its orientation toward the individual and his/her transformation into a personality. The content of institutional education is revealed through the analysis of the institution, which includes a set of established customs, traditions, ways of thinking, behavioral stereotypes of individuals and social groups. The dynamics of socio-political, economic transformations in Ukraine requires a review of the foundations of national education and determination of the prospects for its development in the 21st century in the context of institutionalism.


Molecules ◽  
2021 ◽  
Vol 26 (13) ◽  
pp. 3983
Author(s):  
Ozren Gamulin ◽  
Marko Škrabić ◽  
Kristina Serec ◽  
Matej Par ◽  
Marija Baković ◽  
...  

Gender determination of the human remains can be very challenging, especially in the case of incomplete ones. Herein, we report a proof-of-concept experiment where the possibility of gender recognition using Raman spectroscopy of teeth is investigated. Raman spectra were recorded from male and female molars and premolars on two distinct sites, tooth apex and anatomical neck. Recorded spectra were sorted into suitable datasets and initially analyzed with principal component analysis, which showed a distinction between spectra of male and female teeth. Then, reduced datasets with scores of the first 20 principal components were formed and two classification algorithms, support vector machine and artificial neural networks, were applied to form classification models for gender recognition. The obtained results showed that gender recognition with Raman spectra of teeth is possible but strongly depends both on the tooth type and spectrum recording site. The difference in classification accuracy between different tooth types and recording sites are discussed in terms of the molecular structure difference caused by the influence of masticatory loading or gender-dependent life events.


Author(s):  
Hao Wang ◽  
Ning Li ◽  
Caizhi Wang ◽  
Hongliang Wu ◽  
Peng Liu ◽  
...  

Abstract In the process of dipole-source acoustic far-detection logging, the azimuth of the fracture outside the borehole can be determined with the assumption that the SH–SH wave is stronger than the SV–SV wave. However, in slow formations, the considerable borehole modulation highly complicates the dipole-source radiation of SH and SV waves. A 3D finite-difference time-domain method is used to investigate the responses of the dipole-source reflected shear wave (S–S) in slow formations and explain the relationships between the azimuth characteristics of the S–S wave and the source–receiver offset and the dip angle of the fracture outside the borehole. Results indicate that the SH–SH and SV–SV waves cannot be effectively distinguished by amplitude at some offset ranges under low- and high-fracture dip angle conditions, and the offset ranges are related to formation properties and fracture dip angle. In these cases, the fracture azimuth determined by the amplitude of the S–S wave not only has a $180^\circ $ uncertainty but may also have a $90^\circ $ difference from the actual value. Under these situations, the P–P, S–P and S–S waves can be combined to solve the problem of the $90^\circ $ difference in the azimuth determination of fractures outside the borehole, especially for a low-dip-angle fracture.


Author(s):  
P Bijster ◽  
H L Vader ◽  
C L J Vink

We have shown that the sodium concentration in whole blood measured by direct potentiometry is higher than in plasma. The ‘erythrocyte-effect’, already described by Siggaard Andersen, is most pronounced for instruments equipped with a reference electrode with an open static liquid junction and is thus a general phenomenon. Instruments with a modified liquid junction show less interference. The same phenomenon appears for the determination of the potassium concentration, although the difference between whole blood and plasma, when measured with instruments equipped with a modified liquid junction, can be neglected in practice.


1996 ◽  
Vol 15 (6) ◽  
pp. 497-503 ◽  
Author(s):  
T. Soriano ◽  
M. Menéndez ◽  
P. Sanz ◽  
M. Repetto

1 The described analytical procedure permits the simultaneous determination of the main n-hexane meta bolites in urine. 2-Hexanone, 2-hexanol, 2, 5-hexanediol and 2, 5-hexanedione, were chosen to dose the rats used in this study. All urine samples were collected and analysed on a daily basis, before and after acidic hydrolysis (pH 0.1) by GC/MS. 2-Hexanone, 2, 5-dimethylfurane, γ-valerolac tone and 2, 5-hexanedione were determined before hydro lysis ; 2-hexanol and 2, 5-hexanediol, after hydrolysis; and 5-hydroxy-2-hexanone and 4, 5-dihydroxy-2-hexanone were calculated by the difference between γ-valerolactone and 2, 5-hexanedione with and without hydrolysis, respectively. 2 A metabolic scheme was proposed reflecting the biotransformations undergone by the four compounds assayed. We consider 2, 5-dimethylfurane as a 'true metabolite' because the quantities detected were always greater before hydrolysis. 3 It has been reported that human and rat n-hexane metabolism follow a similar pattern. Therefore, as a practical application and without increasing either sample or time requirements, the simultaneous quantifi cation of the different metabolites and their excretion profile could provide better information about the metabolic situation of exposed workers than the determi nation of 2, 5-hexanedione alone. According to our experimental results, 4, 5-dihydroxy-2-hexanone itself would be a good toxicity indicator.


Sign in / Sign up

Export Citation Format

Share Document