Full-Scale Test and Numerical Simulation of Guided Flexible Protection System under a Blasting Load

2020 ◽  
Vol 26 (2) ◽  
pp. 243-256
Author(s):  
Xin Qi ◽  
Hu Xu ◽  
Zhixiang Yu ◽  
Keqin Sun ◽  
Shichun Zhao

ABSTRACT Both active and passive flexible protection methods are effective against rockfalls, but they can result in a secondary hazard due to cumulate rocks inside the structure. To solve this problem, guided flexible protection systems are receiving increased attention in the engineering community. In this study, a full-scale test of a guided flexible protection system was carried out, where the bottom of the mesh was anchored under a blasting load, which can be considered as an extreme loading event related to rockfall hazards. The fluid-solid coupling method was employed in a finite element model to simulate the entire process from the blast to the accumulation of rocks at the bottom of the slope. Based on the experimental and numerical results, a two-stage process was revealed, the internal force and the dissipated energy of each component were compared and analyzed, and the load-transferring path within the system was obtained. The internal forces of the support ropes reached their maximum values in the intercept stage. The posts experienced two peak values, the first of which, in the guide stage, was twice that in the intercept stage. The brake rings were the main energy-dissipating components, and the energy dissipation in the intercept stage was much greater than that in the guide stage. Furthermore, the interaction in terms of collision and friction between the rocks, the slope, and the system was not insignificant, particularly in the guide stage, which can account for more than 40 percent of the consumed energy of the rockfall.

2012 ◽  
Vol 594-597 ◽  
pp. 1590-1594
Author(s):  
Xiao Zhen Li ◽  
Hong Duan ◽  
Heng Li ◽  
Wei Ye ◽  
Xiao Han Liu

This paper is focused on the load distribution problem, which is especially concerned in design phase, for a long cantilever steel-concrete composite cable-stayed bridge with single tower and single cable plane. A large scale full-scale test is performed to make a systematical study on the load distribution coefficient under different conditions. A refined finite element model is gained by FEM software ANSYS to obtain the theoretical results, which are compared with measured data in model test. Finally, a suggested value of the coefficient is drawn through the test result.


1994 ◽  
Vol 1 (1) ◽  
pp. 77-83
Author(s):  
Yoshiji Moro ◽  
Tomoo Fujita ◽  
Takeshi Kanno ◽  
Akira Kobayashi

2019 ◽  
Vol 18 (1) ◽  
pp. 76-80 ◽  
Author(s):  
Kichul Kim ◽  
Pil-Ju Park ◽  
Soomi Eo ◽  
Seungmi Kwon ◽  
Kwangrae Kim ◽  
...  

1992 ◽  
Vol 35 (3) ◽  
pp. 977-985 ◽  
Author(s):  
K. G. Gebremedhin ◽  
J. A. Bartsch ◽  
M. C. Jorgensen

2020 ◽  
pp. 1420326X2097902
Author(s):  
Hai-Xia Xu ◽  
Yu-Tong Mu ◽  
Yin-Ping Zhang ◽  
Wen-Quan Tao

Most existing models and standards for volatile organic compounds emission assume that contaminants are uniform in the testing devices. In this study, a three-dimensional transient numerical model was proposed to simulate the mass transport process based on a full-scale test chamber with a mixing fan, and the airflow field and contaminants concentration distribution were obtained within the chamber under airtight and ventilated conditions. The model was validated by comparing the numerical results with experimental data. The numerical results show that the contaminant source position and the airflow field characteristics have significant impact on the contaminant mixing, and the fan rotation has an important role in accelerating mixing. In the initial mixing stage, the concentration distribution is obviously uneven; as the mixing progresses, it gradually reaches acceptable uniformity except for some sensitive regions, such as high concentration region at the injection point of the contaminants and low concentration region at the air inlet. To ensure test accuracy, the monitor should avoid above sensitive regions; and some special regions are recommended where contaminant concentration uniformity can be reached sooner. The ventilated chamber results indicate that the mixture of contaminants in the chamber is actually better than the results shown by conventional test method.


2002 ◽  
Vol 218 (1-3) ◽  
pp. 169-178 ◽  
Author(s):  
J.G Liu ◽  
H.L Xiao ◽  
C.P Li

2014 ◽  
Vol 501-504 ◽  
pp. 2132-2137

Removed due to plagiarism. The original was published by: Liu, Deng and Chu (eds) © 2008 Science Press Beijing and Springer-Verlag GmbH Berlin Heidelberg Geotechnical Engineering for Disaster Mitigation and Rehabilitation http://www.ftsl.itb.ac.id/kk/geotechnical_engineering/wp-content/uploads/2008/06/irsyam-165.pdf


2008 ◽  
Vol 51 (2-3) ◽  
pp. 138-155 ◽  
Author(s):  
Peter Gauer ◽  
Karstein Lied ◽  
Krister Kristensen

Sign in / Sign up

Export Citation Format

Share Document