Weight-Bearing CT Scan After Tibial Pilon Fracture Demonstrates Significant Early Joint-Space Narrowing

2020 ◽  
Vol 102 (9) ◽  
pp. 796-803 ◽  
Author(s):  
Michael C. Willey ◽  
Jocelyn T. Compton ◽  
J. Lawrence Marsh ◽  
Conor P. Kleweno ◽  
Julie Agel ◽  
...  
Author(s):  
Michael Willey ◽  
Jocelyn Compton ◽  
Conor Kleweno ◽  
Julie Agel ◽  
Elizabeth Scott ◽  
...  

Author(s):  
Choon Chiet Hong ◽  
Soura Saha ◽  
Si Heng Sharon Tan ◽  
Ken Jin Tan ◽  
Diarmuid Paul Murphy ◽  
...  

2009 ◽  
Vol 69 (01) ◽  
pp. 163-168 ◽  
Author(s):  
M C Nevitt ◽  
Y Zhang ◽  
M K Javaid ◽  
T Neogi ◽  
J R Curtis ◽  
...  

Objectives:Previous studies suggest that high systemic bone mineral density (BMD) is associated with incident knee osteoarthritis (OA) defined by osteophytes but not with joint space narrowing (JSN), and are inconsistent regarding BMD and progression of existing OA. The association of BMD with incident and progressive tibiofemoral OA was tested in a large prospective study of men and women aged 50–79 years with or at risk for knee OA.Methods:Baseline and 30-month weight-bearing posteroanterior and lateral knee radiographs were scored for Kellgren-Lawrence (K-L) grade, JSN and osteophytes. Incident OA was defined as the development of K-L grade ⩾2 at follow-up. All knees were classified for increases in grade of JSN and osteophytes from baseline. The association of gender-specific quartiles of baseline BMD with risk of incident and progressive OA was analysed using logistic regression, adjusting for covariates.Results:The mean (SD) age of 1754 subjects was 63.2 (7.8) years and body mass index was 29.9 (5.4) kg/m2. In knees without baseline OA, higher femoral neck and whole body BMD were associated with an increased risk of incident OA and increases in grade of JSN and osteophytes (p<0.01 for trends); adjusted odds were 2.3–2.9-fold greater in the highest compared with the lowest BMD quartiles. In knees with existing OA, progression was not significantly related to BMD.Conclusions:In knees without OA, higher systemic BMD was associated with a greater risk of the onset of JSN and K-L grade ⩾2. The role of systemic BMD in early knee OA pathogenesis warrants further investigation.


2019 ◽  
Vol 4 (4) ◽  
pp. 2473011419S0008
Author(s):  
Mohamed E. Abdelaziz ◽  
Noortje Hagemeijer ◽  
Daniel Guss ◽  
Ahmed El-Hawary ◽  
A. Holly Johnson ◽  
...  

Category: Ankle, Sports, Trauma, Syndesmosis Introduction/Purpose: Traumatic injuries to the distal tibiofibular syndesmosis are relatively common and can be associated with ankle fractures or occur as purely ligamentous injuries. Unstable syndesmotic injuries require surgical repair, generally performed using either screw or suture button fixation. The superiority of either fixation method remains a subject of ongoing debate. The aim of this study is to compare both clinical and radiographic outcomes of screw and suture button fixation of syndesmosis instability using Patient-Reported Outcomes Measurement Information System (ROMIS) and weight bearing CT scan (WBCT). Methods: Medical records were reviewed to identify patients who had a unilateral syndesmotic injury requiring surgical stabilization and who were at least one year out from injury. Exclusion criteria included patients less than 18 years old, ipsilateral pilon fracture, history of contralateral ankle or pilon fracture or syndesmosis injury, BMI >40, and any neurological impairment. Twenty eligible patients were recruited to complete PROMIS questionnaires and undergo bilateral WBCT scan of both ankles, divided into two groups. In the first group (n=10) the patients had undergone screw fixation of the syndesmosis, while in the second group (n=10) the syndesmosis was fixed using a suture button construct. All patients completed PROMIS questionnaires for pain intensity, pain interference, physical function and depression. Radiographic assessment was performed using axial images of WBCT scan of both the injured ankle and the contralateral normal side at a level one cm proximal to the tibial plafond (Figure 1). Results: At an average follow up of three years, none of the recruited patients required a revision surgery. There was no significant difference between the two groups in terms of the four PROMIS questionnaires (P values ranged from 0.17 to 0.43). In the suture button group, the measurements of the injured side were significantly different from the normal side for the syndesmotic area (P=0.003), fibular rotation (P=0.004), anterior difference (P=0.025) and direct anterior difference (P=0.035). Other measurements of posterior difference, middle difference, direct posterior difference and fibular translation were not significantly different (P values ranged from 0.36 to 0.99). In the screw fixation group, the syndesmotic area was the only significantly different measurement in the injured side as compared to the normal side (P=0.006). Conclusion: Screw and suture button fixation for syndesmotic instability have similar clinical outcomes at average three years follow up as measured by PROMIS scores. Both screw and suture button did not entirely restore the syndesmotic area as compared to the contralateral normal ankle, suggesting some residual diastasis on weight bearing CT. In addition, as compared to screw fixation, the suture button did not seem to restore the normal fibular rotation, with residual external rotation of the fibula noted. Longer clinical follow up is necessary to understand the clinical implication of such malreduction.


2020 ◽  
Vol 5 (2) ◽  
pp. 2473011420S0000
Author(s):  
Mohamed Abdelaziz ◽  
Daniel Guss ◽  
Anne H. Johnson ◽  
Christopher DiGiovanni ◽  
Noortje Hagemeijer ◽  
...  

Category: Trauma; Ankle; Sports Introduction/Purpose: Traumatic injuries to the distal tibiofibular syndesmosis are relatively common and can be associated with ankle fractures or occur as purely ligamentous injuries. Unstable syndesmotic injuries require surgical repair, generally performed using either screw or suture button fixation. The superiority of either fixation method remains a subject of ongoing debate. The aim of this study is to compare both clinical and radiographic outcomes of screw and suture button fixation of syndesmosis instability using Patient-Reported Outcomes Measurement Information System (PROMIS) and weight bearing CT scan (WBCT). Methods: Medical records were reviewed to identify patients who had a unilateral syndesmotic injury requiring surgical stabilization and who were at least one year out from injury. Exclusion criteria included patients less than 18 years old, ipsilateral pilon fracture, history of contralateral ankle or pilon fracture or syndesmosis injury, BMI >40, and any neurological impairment. Twenty eligible patients were recruited to complete PROMIS questionnaires and undergo bilateral WBCT scan of both ankles, divided into two groups. In the first group (n=10) the patients had undergone screw fixation of the syndesmosis, while in the second group (n=10) the syndesmosis was fixed using a suture button construct. All patients completed PROMIS questionnaires for pain intensity, pain interference, physical function and depression. Radiographic assessment was performed using axial images of WBCT scan of both the injured ankle and the contralateral normal side at a level one cm proximal to the tibial plafond ( Figure 1 ). Results: At an average follow up of three years, none of the recruited patients required a revision surgery. There was no significant difference between the two groups in terms of the four PROMIS questionnaires (P values ranged from 0.17 to 0.43). In the suture button group, the measurements of the injured side were significantly different from the normal side for the syndesmotic area (P=0.003), fibular rotation (P=0.004), anterior difference (P=0.025) and direct anterior difference (P=0.035). Other measurements of posterior difference, middle difference, direct posterior difference and fibular translation were not significantly different (P values ranged from 0.36 to 0.99). In the screw fixation group, the syndesmotic area was the only significantly different measurement in the injured side as compared to the normal side (P=0.006). Conclusion: Screw and suture button fixation for syndesmotic instability have similar clinical outcomes at average three years follow up as measured by PROMIS scores. Both screw and suture button did not entirely restore the syndesmotic area as compared to the contralateral normal ankle, suggesting some residual diastasis on weight bearing CT. In addition, as compared to screw fixation, the suture button did not seem to restore the normal fibular rotation, with residual external rotation of the fibula noted. Longer clinical follow up is necessary to understand the clinical implication of such malreduction.


2012 ◽  
Vol 51 (3) ◽  
pp. 362-364 ◽  
Author(s):  
Prasad Ellanti ◽  
Yassir Hammad ◽  
Damir Kosutic ◽  
Philip P. Grieve

1997 ◽  
Vol 38 (6) ◽  
pp. 1063-1070 ◽  
Author(s):  
T. Boegård ◽  
O. Rudling ◽  
I. F. Petersson ◽  
J. Sanfridsson ◽  
T. Saxne ◽  
...  

Purpose: the purpose was four-fold: to assess the reproducibility of p.a. weight-bearing radiograms of the knee and the minimal joint-space (MJS) width measurements in these radiograms; to compare the MJS with MR-detected cartilage defects; to evaluate the location of these cartilage defects; and to estimate the relation between meniscal abnormalities and joint-space narrowing Material and Methods: Fifty-nine individuals, aged 41–58 years (mean 50), with chronic knee pain were examined by means of p.a. weight-bearing radiograms in semi-flexion with fluoroscopic guidance of the knee joint. the MJS was measured with a standard ruler. on the same day MR imaging was performed with proton-density- and T2-weighted turbo spin-echo on a 1.0 T imager. Meniscal abnormalities and cartilage defects in the tibiofemoral joint (TFJ) were noted Results and Conclusion: the p.a. view of the knee and the MJS measurements were reproducible. MJS of 3 mm is a limit in diagnosing joint-space narrowing in knees with MR-detected cartilage defects. There was a high proportion <p<0.001) of meniscal abnormality within the narrowed compartments in comparison with those that were not narrowed. A larger number of the cartilage defects (p<0.05) was found in the medial femoral condyle than in any of the other condyles of the TFJ. the defects had a dorsal location <p<0.001) as shown in the weight-bearing radiograms of the knee in semiflexion


Injury ◽  
2017 ◽  
Vol 48 (6) ◽  
pp. 1258-1263 ◽  
Author(s):  
Jorge De-las-Heras-Romero ◽  
Ana M. Lledo-Alvarez ◽  
Alejandro Lizaur-Utrilla ◽  
Fernando A. Lopez-Prats

Sign in / Sign up

Export Citation Format

Share Document