Images at 1 month follow-up show stent in the true lumen of the descending aorta and decreased size of false lumen adjacent to stent

ASVIDE ◽  
2018 ◽  
Vol 5 ◽  
pp. 367-367
Author(s):  
Paul Schoenhagen
Aorta ◽  
2017 ◽  
Vol 05 (04) ◽  
pp. 124-128 ◽  
Author(s):  
Vamshi Krishna Kotha ◽  
Zlatko Pozeg ◽  
Eric Herget ◽  
Michael Moon ◽  
Jehangir Appoo ◽  
...  

AbstractConventional surgical techniques for acute Type A aortic dissection (ATAAD) generally fail to address residual dissection in the descending aorta. The persistence of a false lumen is associated with visceral malperfusion in the acute setting and adverse aortic remodeling in the chronic setting. Hybrid aortic arch repair techniques may improve perioperative and long-term mortality by expanding the true lumen and obliterating the false lumen. However, there is a limit to the extent of aortic coverage due to the concomitant risk of spinal cord ischemia. In Type B dissection, the PETTICOAT (Provisional Extension To Induce Complete Attachment) technique, which entails stent graft coverage of the primary intimal tear followed by bare metal stent placement distally, may improve true lumen caliber and promote false lumen thrombosis without increasing the risk of spinal cord ischemia, as intercostal branches remain perfused through the bare metal stents. The technique of hybrid arch with surgical creation of a Dacron landing zone covering a stent graft in the proximal descending aorta and bare metal stents in the thoraco-abdominal aorta is a promising concept in the treatment of ATAAD.


2020 ◽  
Vol 15 (1) ◽  
Author(s):  
Zanxin Wang ◽  
Xianmian Zhuang ◽  
Bailang Chen ◽  
Junmin Wen ◽  
Minxin Wei

Abstract Background The present study aimed to evaluate the effect of two-stage hybrid aortic repair at the distal aorta of Stanford A dissection with malperfusion. Methods This retrospective case series included 20 patients with Stanford A dissection administered two-stage thoracic endovascular aortic repair (TEVAR) about 1 month after central repair because of visceral or limb malperfusion. The patients were examined by computed tomography (CT) angiography at 3, 6, 12 and 24 months after operation. Recovery of malperfusion and true lumen index were evaluated during follow-up. Results Twenty patients underwent two-stage hybrid aortic repair, including 11 males and 9 females. The follow-up time was 24 ± 7 months. No intervention-related complications were observed, including stent graft-induced new re-entry tears, death, stroke and spinal cord injury. Malperfusion in all cases was corrected. The true lumen was not enlarged enough 1 month after the first surgery. Thrombosis of the false lumen was observed around the elephant trunk at the carina level and the celiac artery. Three months after second stage TEVAR, the false lumen thrombosis was resorbed; in addition, the trunk was fully expanded at the carina level, and the true lumen was enlarged at the celiac artery. Conclusions Two-stage hybrid aortic repair for residual true lumen in the distal aorta 1 month after initial surgery is helpful for descending aorta remodeling and effective in treating malperfusion. This procedure may be a good option for patients suffering from Stanford A dissection with small true lumen in the distal aorta and malperfusion.


2020 ◽  
pp. 152660282096699
Author(s):  
Yaowang Lin ◽  
Shaohong Dong ◽  
Jianfan Luo ◽  
Weijie Bei ◽  
Qiyun Liu ◽  
...  

Purpose To compare the clinical outcomes after thoracic endovascular aortic repair (TEVAR) with a bare stent to those after TEVAR alone in patients with complicated acute type B aortic dissection (cATBAD). Materials and Methods A prospective, randomized trial was conducted at 2 medical centers in China between 2010 and 2013. Patients with cATBAD were randomly assigned to receive TEVAR with a bare stent (n=42) or TEVAR only (n=42). Patients were scheduled to undergo computed tomography angiography at 3, 6, and 12 months and then annually to 5 years. The primary endpoint was all-cause mortality at 5 years; secondary outcomes were a composite of complications (endoleak, stent-graft–induced new entry, aortic rupture, and secondary intervention) and aortic remodeling at 1 and 5 years. Results All-cause death occurred in 1 (2.4%) patient in the TEVAR with bare stent group (lung cancer) and 5 patients (11.9%) in the TEVAR group (4 aorta-related) during the 5-year follow-up (log-rank p=0.025). The 1- and 5-year rates of complications and secondary interventions did not differ between the groups. Patients in the TEVAR with bare stent group had higher increases in the thoracic true lumen diameter (19.7±3.6 vs 17.0±6.2 mm, p=0.018) and abdominal true lumen diameter (13.7±4.8 vs 7.2±6.1 mm, p<0.001) and a higher incidence of complete false lumen thrombosis (80.9% vs 47.6%, p=0.005) at the 1-year follow-up. However, no between-group differences in the changes of aortic remodeling parameters were observed between the 1- and 5-year follow-up periods. Conclusion The addition of a distal bare stent to a thoracic stent-graft during TEVAR was associated with significantly improved long-term survival in cATBAD patients vs TEVAR only, likely due to the prevention of true lumen collapse and improvement of complete false lumen thrombosis of the dissected aorta.


Author(s):  
Daichi Takagi ◽  
Takuya Wada ◽  
Wataru Igarashi ◽  
Takayuki Kadohama ◽  
kentaro kiryu ◽  
...  

We describe a case of frozen elephant trunk deployment unintentionally malpositioned into the false lumen. An 83-year-old man underwent total arch repair with a frozen elephant trunk for type A acute aortic dissection complicated by mesenteric malperfusion. However, intraoperative transesophageal echocardiography showed expansion of the false lumen in the descending aorta, suggesting a malpositioned frozen elephant trunk into the false lumen. Endovascular fenestration of the dissecting flap and subsequent endograft deployment from the inside of the malpositioned frozen elephant trunk graft to the true lumen of the descending aorta was successfully performed under intravascular ultrasound guidance.


Circulation ◽  
2000 ◽  
Vol 102 (suppl_3) ◽  
Author(s):  
Hiromu Terai ◽  
Nobushige Tamura ◽  
Tatsuo Nakamura ◽  
Kazunobu Nishimura ◽  
Norimasa Tsutsui ◽  
...  

Background —Despite recent progress in medical and surgical treatment, acute type B aortic dissection still carries a high mortality rate. We have developed a novel cylindrical balloon catheter for less invasive treatment to block the entry of the dissection and induce thrombotic occlusion of the false lumen. The balloon has the shape of a sheet when deflated but a double-cylinder shape when inflated. Therefore, aortic blood flow is maintained through the cylindrical lumen during balloon inflation. Methods and Results —Six beagle dogs underwent a left thoracotomy at the 6th intercostal space. An acute dissection of 4-cm length was created surgically on the descending aorta. The balloon catheter was inserted through the distal descending aorta and advanced to the entry site. The balloon catheter was inflated for 6 hours. The blood flow in the descending aorta and the position of the balloon was monitored by color Doppler echovasculography. Four dogs were killed humanely on the following day and 2 dogs 10 days after the surgery. The descending aorta was examined macroscopically and microscopically in all dogs. In all dogs, the false lumen was occluded by thrombi. Although no dog had clinical evidence of distal thromboembolism, 2 of the 4 dogs that were killed on the second postoperative day had fresh mural thrombi in the true lumen. Conclusions —The false lumen of the acute type B aortic dissection was effectively occluded by the novel cylindrical balloon catheter in the canine experimental model. The thrombus formation in the true lumen is the problem to be solved.


2020 ◽  
Vol 21 (Supplement_1) ◽  
Author(s):  
A Ruiz Munoz ◽  
A Guala ◽  
G Teixido-Tura ◽  
L Dux-Santoy ◽  
A Sao-Aviles ◽  
...  

Abstract Background Due to improved surgical strategies a growing number of patients survive acute aortic dissection. Patent false lumen (FL) is common in chronic dissection and it has been associated with poor prognosis, which is mainly driven by FL expansion. Several variables indirectly related to flow characteristics have been associated with progressive aortic dilation. We aimed to evaluate whether the maximum systolic flow deceleration rate (MSDR) in the FL, quantified by 4D-flow MR, is related to FL dilation in chronic type B aortic dissection. Methods Twenty-nine patients with a patent FL after aortic dissection and a prior follow-up of at least 3 years underwent contrast-enhanced 4D-flow MR. Marfan patients were excluded. Time-resolved FL flow acceleration was calculated in a 5 cm-long volume of the descending aorta around the level of the pulmonary bifurcation. MSDR was determined as the maximum minus the minimum acceleration in systole over the corresponding time interval (Figure 1a). Aortic growth rate (GR) was measured as the difference between final and initial maximum FL diameters obtained by angio-CT divided by follow-up duration. Population was divided into tertiles based on GR. Results Demographic and clinical variables were similar among GR tertiles (Table). MSDR was lower in patients with a GR &lt;1mm/year (group 1) compared to both the other two patient groups (p = 0.009 and 0.003 for groups 2 and 3, respectively) (Figure 1c). MSDR showed a marked positive linear correlation with GR (R = 0.481, p = 0.008) (Figure 1b). Conclusions The MSDR in the FL of chronic type B aortic dissection is linearly related to FL growth rate and discriminated between tertiles of aortic dilation. Prospective longitudinal studies are need to unveil possible prognostic value of this parameter. Table Group 1 (n = 9) Group 2 (n = 10) Group 3 (n = 10) p-value Age (years) 63.44 ±13.54 62.50 ± 13.60 64.56 ± 6.67 0.902 BSA (m2) 2.00 ± 0.18 1.77 ± 0.20 1.94 ± 0.12 0.213 Men 6 (86%) 4 (57%) 4 (100%) 0.210 Hypertension 4 (66%) 5 (71%) 4 (100%) 0.438 Atheroclerosis 1 (17%) 1 (14%) 0 (0%) 0.699 Initial Diameter (mm) 45.00 ± 7.69 36.00 ± 4.20 37.00 ± 6.48 0.078 Final Diameter (mm) 49.50 ± 6.74 44.86 ± 5.70 59.25 ± 9.84 0.049 Follow-up (year) 11.83 ± 8.79 7.82 ± 3.34 8.08 ± 4.05 0.921 GR (mm/year) 0.27 ± 0.29 1.18 ± 0.26 2.64 ± 0.97 &lt;0.001 MSDR (cm/s3) 1212.18 ± 467.61 2410.54 ± 1034.30 2558.16 ± 1098.06 0.005 Abstract P1600 Figure 1


2017 ◽  
Vol 2017 ◽  
pp. 1-6 ◽  
Author(s):  
Michael Trojan ◽  
Fabian Rengier ◽  
Drosos Kotelis ◽  
Matthias Müller-Eschner ◽  
Sasan Partovi ◽  
...  

Objective. To prospectively evaluate our hypothesis that three-dimensional time-resolved contrast-enhanced magnetic resonance angiography (TR-MRA) is able to detect hemodynamic alterations in patients with chronic expanding aortic dissection compared to stable aortic dissections. Materials and Methods. 20 patients with chronic or residual aortic dissection in the descending aorta and patent false lumen underwent TR-MRA of the aorta at 1.5 T and repeated follow-up imaging (mean follow-up 5.4 years). 7 patients showed chronic aortic expansion and 13 patients had stable aortic diameters. Regions of interest were placed in the nondissected ascending aorta and the false lumen of the descending aorta at the level of the diaphragm (FL-diaphragm level) resulting in respective time-intensity curves. Results. For the FL-diaphragm level, time-to-peak intensity and full width at half maximum were significantly shorter in the expansion group compared to the stable group (p=0.027 and p=0.003), and upward and downward slopes of time-intensity curves were significantly steeper (p=0.015 and p=0.005). The delay of peak intensity in the FL-diaphragm level compared to the nondissected ascending aorta was significantly shorter in the expansion group compared to the stable group (p=0.01). Conclusions. 3D TR-MRA detects significant alterations of hemodynamics within the patent false lumen of chronic expanding aortic dissections compared to stable aortic dissections.


Vascular ◽  
2015 ◽  
Vol 24 (1) ◽  
pp. 103-105 ◽  
Author(s):  
Joe Anderson ◽  
Tyler Remund ◽  
Katie Pohlson ◽  
Patrick Kelly

Here we present three cases performed using a novel technique where aortic flow is compartmentalized proximal to the target vessels through a physician-modified endograft. The visceral segment is then further compartmentalized by the use of another physician modified endograft. By compartmentalizing the flow proximal to the visceral segment, both the true lumen and false lumen can be used as conduits for coextensive bridging stent grafts. Overall, patients have tolerated this procedure extremely well, and while further study and follow-up must be conducted, this procedure could offer a reasonable long-term solution to thoracoabdominal aortic aneurysms complicated by dissection.


Sign in / Sign up

Export Citation Format

Share Document