scholarly journals PVC membrane and All-Solid-Sate Sensor for the Potentiometric Analysis of Trimipramine

2019 ◽  
pp. 10681-10692
Author(s):  
Maryam Sharifi-Sistani ◽  
2020 ◽  
Vol 16 (2) ◽  
pp. 168-175 ◽  
Author(s):  
Merve Tumur ◽  
Gulsah Saydan Kanberoglu ◽  
Fatih Coldur

Background: Cysteamine is used as an orphan drug in the treatment of cystinosis to prevent long-term cystine accumulation in lysosomes. Dosing in cysteamine treatment is extremely important and overdose may cause some side effects. Up to now, various analytical methods have been used for cysteamine determination. Many of these methods require sophisticated instruments, expert operators, time-consuming measurement procedures and manipulation steps, expensive supplies and long analysis time. Aims and Objective: The present study deals with the development of a potentiometric PVC-membrane cysteamine-selective electrode based on an ion-pair of cysteamine and its application in a pharmaceutical formulation. Methods: Cysteamine (Cys)-Phosphomolybdate (PM) ion-pair was synthesized by mixing the equal volumes of 10-2 M Cysteamine HCl and sodium phosphomolybdate aqueous solutions. The obtained precipitate was used as ionophore in the structure of PVC-membrane. Results and Discussion: The electrode exhibited a linear response in the concentration range of 1.0×10- 1-1.0×10-5 M cysteamine with a slope of 51,7 mV per decade and detection limit of 1.0×10-5 M. The potentiometric response of the electrode was very rapid (5 s), adequately repeatable, stable and selective. pH working range and life-time of the electrode were also determined as 3.0-7.0 and 25 days, respectively. Conclusion: A PVC-membrane cysteamine selective electrode was easily prepared. Cysteamine determination in a pharmaceutical formulation was performed. Analysis results indicated that it can be successfully used in drug quality control laboratories for routine analysis of cysteamine in pharmaceutical preparations alternative to more sophisticated, expensive and time-consuming analytical methods.


2020 ◽  
Vol 40 (10) ◽  
pp. 842-847
Author(s):  
Shankar Suman ◽  
Ram Singh

AbstractA new poly (vinyl chloride) (PVC) membrane electrode using 2-benzoylpyridine semicarbazone as membrane carrier with dioctylphthalate as plasticizer and sodium tetraphenylborate (NaTBP) as anion excluder has been fabricated and investigated as Zn(II)-selective electrode. Best potential response is observed for the composition PVC 30%, plasticizer 58%, NaTBP 8% and ionophore 4% (w/w). The sensor showed a linear stable response over a concentration range of 1.0 × 10−2–4.56 × 10−6 M with a detection limit of 2.28 × 10−6 M and a response time <10 s. The electrode can be used for at least six months without any divergence in potential.


Author(s):  
Guoqiang Chai ◽  
Guoqing Zhu ◽  
Jinju Zhou ◽  
Yunji Gao ◽  
Ying Zhou ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (9) ◽  
pp. 3150
Author(s):  
Fatehy M. Abdel-Haleem ◽  
Sonia Mahmoud ◽  
Nour Eldin T. Abdel-Ghani ◽  
Rasha Mohamed El Nashar ◽  
Mikhael Bechelany ◽  
...  

Levofloxacin (LF) is a medically important antibiotic drug that is used to treat a variety of bacterial infections. In this study, three highly sensitive and selective carbon paste electrodes (CPEs) were fabricated for potentiometric determination of the LF drug: (i) CPEs filled with carbon paste (referred to as CPE); (ii) CPE coated (drop-casted) with ion-selective PVC membrane (referred to as C-CPE); (iii) CPE filled with carbon paste modified with a plasticizer (PVC/cyclohexanone) (referenced as P-CPE). The CPE was formulated from graphite (Gr, 44.0%) and reduced graphene oxide (rGO, 3.0%) as the carbon source, tricresyl phosphate (TCP, 47.0%) as the plasticizer; sodium tetrakis[3,5-bis(trifluoromethyl)phenyl] borate (St-TFPMB, 1.0%) as the ion exchanger; and levofloxacinium-tetraphenylborate (LF-TPB, 5.0%) as the lipophilic ion pair. It showed a sub-Nernstian slope of 49.3 mV decade−1 within the LF concentration range 1.0 × 10−2 M to 1.0 × 10−5 M, with a detection limit of 1.0 × 10−5 M. The PVC coated electrode (C-CPE) showed improved sensitivity (in terms of slope, equal to 50.2 mV decade−1) compared to CPEs. After the incorporation of PVC paste on the modified CPE (P-CPE), the sensitivity increased at 53.5 mV decade−1, indicating such improvement. The selectivity coefficient (log KLF2+,Fe+3pot.) against different interfering species (Na+, K+, NH4+, Ca2+, Al3+, Fe3+, Glycine, Glucose, Maltose, Lactose) were significantly improved by one to three orders of magnitudes in the case of C-CPE and P-CPE, compared to CPEs. The modification with the PVC membrane coating significantly improved the response time and solubility of the LF-TPB within the electrode matrix and increased the lifetime. The constructed sensors were successfully applied for LF determination in pharmaceutical preparation (Levoxin® 500 mg), spiked urine, and serum samples with high accuracy and precision.


1997 ◽  
Vol 349 (1-3) ◽  
pp. 59-65 ◽  
Author(s):  
M. Gerlache ◽  
Z. Sentürk ◽  
J.C. Viré ◽  
J.M. Kauffmann

1974 ◽  
Vol 73 (2) ◽  
pp. 375-382 ◽  
Author(s):  
Marco Mascini ◽  
Franco Pallozzi

Sign in / Sign up

Export Citation Format

Share Document