Corrosion Behavior of Coated and Uncoated Nickel-Titanium Orthodontic Wires in Artificial Saliva with Short-term Prophylactic Fluoride Treatment

Author(s):  
Višnja Katić ◽  
Author(s):  
A. Christy Catherine Mary ◽  
J. Jeyasundari ◽  
V.R. Nazeera Banu ◽  
R. Dorothy ◽  
Susai Rajendran ◽  
...  

2018 ◽  
Vol 917 ◽  
pp. 197-201
Author(s):  
Aphinan Phukaoluan ◽  
Anak Khantachawana ◽  
Pongpan Kaewtatip ◽  
Surachai Dechkunakorn

The aim of this study, the corrosion behavior of TiNiCu in artificial saliva (pH5.35) at 37°C was assessed by the use of electrochemical methods. Ti50Ni43Cu7 (at%) used in this study were made from ingots prepared by the vacuum arc melting (VAM) method. The furnace was purged with argon gas during melting. All melted ingots were then homogenized at 800°C for 3.6 ks. Open circuit potential (OCP) was monitored at 3.6 ks followed by potentiodynamic techniques. The results showed that all chemical composition of orthodontic wires by EPMA were Ti, Ni, Cu, Cr, Fe and Mn. Surface roughness was measured in order to ensure that TiNiCu and SS was significant difference which might affect corrosion resistance. It was seen that TiNiCu orthodontic wires, presented a good corrosion resistance, compared to the stainless steel, probably due to the formation of a protective oxide film mainly constituted by titanium oxide.


2013 ◽  
Vol 83 (5) ◽  
pp. 864-869 ◽  
Author(s):  
Elisa J. Kassab ◽  
José Ponciano Gomes

ABSTRACT Objective: To assess the influence of fluoride concentration on the corrosion behavior of nickel titanium (NiTi) superelastic wire and to compare the corrosion resistance of NiTi with that of beta titanium alloy in physiological solution with and without addition of fluoride. Materials and Methods: NiTi corrosion resistance was investigated through electrochemical impedance spectroscopy and anodic polarization in sodium chloride (NaCl 0.15 M) with and without addition of 0.02 M sodium fluoride (NaF), and the results were compared with those associated with beta titanium. The influence of fluoride concentration on NiTi corrosion behavior was assessed in NaCl (0.15 M) with and without 0.02, 0.04, 0.05, 0.07, and 0.12 M NaF solution. Galvanic corrosion between NiTi and beta titanium were investigated. All samples were characterized by scanning electron microscopy. Results: Polarization resistance decreased when NaF concentration was increased, and, depending on NaF concentration, NiTi can suffer localized or generalized corrosion. In NaCl solution with 0.02 M NaF, NiTi suffer localized corrosion, while beta titanium alloys remained passive. Current values near zero were observed by galvanic coupling of NiTi and beta titanium. Conclusions: There is a decrease in NiTi corrosion resistance in the presence of fluoride. The corrosion behavior of NiTi alloy depends on fluoride concentration. When 0.02 and 0.04 M of NaF were added to the NaCl solution, NiTi presented localized corrosion. When NaF concentration increased to 0.05, 0.07, and 0.12 M, the alloy presented general corrosion. NiTi corrosion resistance behavior is lower than that of beta titanium. Galvanic coupling of these alloys does not increase corrosion rates.


Sign in / Sign up

Export Citation Format

Share Document